System Log Messages



Version 5.2.1-5020115686


Identifier

Message

Code

Description

Severity

system_drop

lost %[drops]d %[msgs]s

10002

Unable to deliver system log(s) to nvlogd, so system logs dropped


update_find_server_failed

Failed to contact update server

11006

Failed to find update server

warn

update_wrong_redirect

Unexpected redirect %[url]s from update server

11007

Got an unexpected redirect from http update server lookup

warn

nvOSd_start

===== nvOSd start: version=%[version]s changeset=%[changeset]s branch=%[branch]s

11008

nvOSd startup

note

pkt_alloc_failed

%[feature]s failed to allocate a send buffer

11009

Failed to allocate a packet for sending from the CPU

warn

syscall_failed_critical

%[feature]s: %[syscall]s failed: %[err]m

11012

A system call failed

critical

restart_nvOSd

Restarting %[exe]s

11013

restarting nvOSd

note

restart_nvOSd_failed

Failed to restart %[exe]s: %[err]m

11014

failed to restart nvOSd

critical

nvOSd_init_failed

nvOSd failed to start: %[feature]s: %[err]m

11015

nvOSd was unable to start

critical

loop_detected

LOOP: mac %[mac]M %[net]N on switch %[old_switch]n port %[old_port]d (%[old_ip]I), also on switch %[new_switch]n port %[new_port]d (%[new_ip]I) %[caller]s

11016

detected an L2 loop

note

mac_moved

MOVING MAC=%[mac]M, vnet=%[vnet]s vlan %[vlan]d from switch %[old_switch]n %[old_port]d (%[old_ip]I) to switch %[new_switch]n %[new_port]d %[new_ip]I %[caller]s

11017

mac moved from one port to another

note

simulator_mode

Failed to init switch hardware

11018

simulator mode entered but not from command line

critical

fabric_joined

Joined fabric %[fabname]s

11019

switch joined a fabric

note

fabric_unjoined

Unjoined fabric %[fabname]s

11020

switch unjoined the fabric

note

config_imported

imported configuration from file %[file]s

11021

imported a new configuration

note

stp_switch_enable_failed

STP failed to initialize for switch hardware

11028

STP initialization for underlying switch hardware failed

critical

stp_default_spanning_tree_failed

STP Failed to Create Default Spanning Tree: vlan=%[vlan]d

11029

Unable to create the Spanning Tree for the default VLAN

critical

stp_flow

STP Failed to install flow(s) for BPDU reception: flow=%[flow]s

11030

Unable to install STP flow(s) for the reception of STP packets

critical

stp_worker_thread_failed

STP failed to create worker thread: vlan=%[vlan]d

11031

STP was unable to create worker thread for Spanning Tree

critical

stp_config_failed

loading and application STP configuration failed.

11041

The loading and application of STP configuration failed

warn

stp_set_port_state_failed

STP Port State Failure: port=%[port]d vlan=%[vlan]d

11045

Unable to set the port state for the port on the vlan

critical

stp_trunk_port_state

STP Set Port State: port=%[port]d vlan=%[vlan]d trunk=%[trunk]d

11046

invalid trunk in use by the spanning tree

warn

mcast_switch_init

igmp/mld snooping unable to initialize switch hardware for groups

11047

igmp/mld was unable to initialize the switch hardware for groups

critical

igmp_flow_add

igmp snooping unable to add flow: flow=%[flow]s

11048

igmp was unable to add a flow for IGMP packet processing

warn

igmp_flow_remove

igmp snooping not able to remove flow: flow=%[flow]s

11049

igmp snooping unable to remove flow for igmp processing

warn

igmp_query_start

igmp snooping unable to start query state machine

11050

igmp was not able to start query state machine

warn

igmp_query_stop

igmp snooping unable to stop query state machine

11051

igmp was not able to stop the query state machine

warn

mcast_switch_fini

igmp/mld snooping unable to halt switch hardware for groups

11052

igmp/mld snooping unable to halt switch hardware for groups

warn

igmp_static_load

igmp snooping unable to load static igmp group

11053

igmp snooping unable to load static igmp group

warn

igmp_static_source_load

igmp snooping unable to load static igmp group source list

11054

igmp snooping unable to load static igmp group source list

warn

igmp_flooding

igmp flooding not enabled

11055

igmp flooding not enabled

warn

mcast_group_add_failed

IGMP/MLD Group Add Failed: vlan=%[vlan]d group=%[group]s

11071

mcast snooping failed to add a group to switch hardware

warn

mcast_group_remove_failed

IGMP/MLD Group Remove Failed: vlan=%[vlan]d group=%[group]s

11072

mcast snooping failed to remove a group from switch hardware

warn

software_upgrade_initiated

nvOS software upgrade initiated for %[verinfo]s

11073

software upgrade initiated; downloading and installing new packages

note

software_upgrade_complete

System and nvOS software upgrade complete: %[verinfo]s

11074

system OS and nvOS software upgrade complete

note

software_upgrade_failed

nvOS software upgrade failed: %[err]s

11075

software upgrade failed

warn

system_reboot

System reboot initiated by nvOSd

11076

system reboot initiated by nvOSd

note

system_reboot_failed

System reboot initiated by nvOSd failed

11077

system reboot initiated by nvOSd failed

warn

lldp_agent_create_thread_failed

LLDP Agent Thread Create Failed: mac=%[mac]s group=%[group]s error=%[error]d

11079

Createion of thread for LLDP Agent failed

warn

lldp_flow_add_failed

LLDP Flow Add Failed: flow=%[flow]s

11080

addling flow for LLDP packet reception failed

warn

lldp_flow_remove_failed

LLDP Flow Remove Failed: flow=%[flow]s

11081

removing flow for LLDP packet reception failed

warn

evb_platform_not_supported

EVB is not supported on this platform: port=%[port]d

11089

EVB not supported on this platform

warn

evb_ecp_not_enabled

EVB ECP Is Not Enabled: port=%[port]d

11090

received EVB TLV with ECP not enabled

warn

evb_flow_remove_failed

EVB Flow Remove Failed: flowstr=%[flowstr]s

11095

unable to remove specified EVB flow

warn

lldp_agent_create_failure

LLDP Agent Create Failed: agent=%[agent]s

11111

Failed to create LLDP Agent for one of three agent addresses

warn

stats_log_open_failed

file=%[file]s: stats log file open failed

11140

Log file open failed

warn

container_rebuild_start

container=%[container]s rebuild is started

11141

container rebuild is started

note

container_rebuild_end

container=%[container]s rebuild is completed

11142

container rebuild is completed

note

all_container_rebuild

all containers are rebuilt

11143

all containers are rebuilt

note

loop_broken

LOOP Broken: port=%[port]d vlan=%[vlan]d mac=%[mac]s ip=%[ip]s

11180

A loop was broken on port/vlan for mac/ip


loop_stp

LOOP STP: port=%[port]d vlan=%[vlan]d mac=%[mac]s ip=%[ip]s

11181

A loop was detected that STP should have prevented

warn

update_auto_upgrade

PN Cloud initiated software upgrade

11210

update server initiated upgrade

note

update_error

Error message from PN Clould: %[msg]s

11211

update server sent an error message

warn

ps_initial_status

Power supply %[psu]d initial status %[status]s

11302

Power supply initial status

warn

fan_initial_status

Fan %[fan]d initial status %[status]s

11303

Fan initial status

warn

ps_status_change

Power supply %[psu]d changed from %[init_status]s to %[new_status]s

11304

Power supply state change

warn

fan_status_change

Fan %[fan]d changed from %[init_status]s to %[new_status]s

11305

Fan status change

warn

fabric_node_duplicate_ip

Fabric node has the same ip=%[ip]I as the local node, cannot send to it

11319

Fabric node has the same IP as the local node, cannot send to it.

warn

upgrade_error

software upgrade error: %[name]s: %[func]s - %[err]s

11324

Software Upgrade errors

warn

upgrade_informational

software upgrade note: %[name]s: %[func]s - %[info]s

11325

Software Upgrade informational messages

note

upgrade_reboot

System reboot initiated by upgrade agent

11326

system reboot initiated by software upgrade

note

upgrade_reboot_failed

System reboot initiated by upgrade agent failed

11327

system reboot initiated by software upgrade failed

warn

openstack_nat_failed

Failed to setup NAT on the OpenStack controller %[name]s

11328

failed to configure nat for openstack

warn

mac_tunnel_to_port

MOVING MAC=%[mac]M, vnet=%[vnet]s vlan=%[vlan]d from tunnel=%[tunnel]s ip=%[old_ip]I to port=%[port]d ip=%[new_ip]I %[caller]s

11329

mac moved from a tunnel to a port

note

mac_port_to_switch

MOVING MAC=%[mac]M, vlan=%[vlan]d from switch=%[old_sw]s port=%[old_port]d ip=%[old_ip]I to switch=%[new_sw]s port=%[new_port]d ip=%[new_ip]I %[caller]s

11330

mac moved from a port to another switch

note

mld_flow_add

mld snooping unable to add flow: flow=%[flow]s

11341

mld was unable to add a flow for MLD packet processing

warn

mld_flow_remove

mld snooping not able to remove flow: flow=%[flow]s

11342

mld snooping unable to remove flow for mld processing

warn

mld_query_start

mld snooping unable to start query state machine

11343

mld was not able to start query state machine

warn

mld_query_stop

mld snooping unable to stop query state machine

11344

mld was not able to stop the query state machine

warn

mld_static_load

mld snooping unable to load static mld group

11345

mld snooping unable to load static mld group

warn

mld_static_source_load

mld snooping unable to load static mld group source list

11346

mld snooping unable to load static mld group source list

warn

xact_node_ignored

Ignoring offline or out of sync cluster node name=%[name]s for transaction tid=%[tid]d

11366

ignored offline or out of sync cluster node for transaction

warn

xact_recover

Transactions out-of-sync detected, rolled forward from old=%[old]d to new=%[new]d via node=%[node]s

11367

auto-recovered from transactions being out of sync

warn

xact_recover_failed

Transaction auto-recover failed: %[msg]s

11368

auto-recover attempted but failed

warn

ip_moved

Moving ip=%[ip]I from old-mac=%[old_mac]M to new-mac=%[new_mac]M

11369

IP address moved from one mac to another

note

software_license_expiring

software license(s) expiring soon code=%[code]s expires_on=%[expires_on]s

11370

software license(s) expiring

warn

software_license_expired

software license(s) have expired code=%[code]s expired_on=%[expires_on]s

11371

software license(s) have expired

warn

l2_check_missing

Add missing l2 entry to hardware: mac=%[mac]M %[net]N vxlan=%[vxlan]d port=%[port]d tunnel=%[tunnel_name]s result=%[result]s

11376

Add layer 2 entry that was missing in hardware

warn

l2_check_bad_port

Fix l2 entry in hardware with incorrect port: mac=%[mac]M %[net]N vxlan=%[vxlan]d old_port=%[old_port]d new_port=%[new_port]d result=%[result]s

11377

Fix layer 2 entry in hardware with incorrect port

warn

l2_check_orphaned

Remove orphaned l2 entry from hardware: mac=%[mac]M %[net]N vxlan=%[vxlan]d port=%[port]d tunnel=%[tunnel]s result=%[result]s

11378

Remove orphaned layer 2 entry in hardware (not in software table)

warn

mac_move_denied

MOVE DENIED mac=%[mac]M %[net]N from switch=%[sw]n port=%[port]d to deny-switch=%[deny_sw]n deny-port=%[deny_port]d reason=%[reason]s

11379

Mac moved not allowed

note

host_port_loop_detected

Looping traffic detected on switch=%[sw]n local-host-port=%[port]d %[net]N. Traffic on this port/network will be ignored until loop resolved

11380

loop detected on host port

warn

host_port_loop_resolved

Traffic has stopped looping on host-port=%[port]d %[net]N

11381

loop on host port is no longer happening

note

owner_mac_moved

caller=%[caller]s owner=%[owner]n mac=%[mac]M vnet=%[vnet]s vlan=%[vlan]d moved from old-local-port=%[old_port]d to new-local-port=%[new_port]d

11382

other switch's mac moved from one local port to another

note

mstp_set_port_state_failed

STP Port State Failure: port=%[port]d instance=%[instance]d

11384

Unable to set the stp state for the port on the MST instance

critical

mac_port_to_tunnel

MOVING MAC=%[mac]M, vnet=%[vnet]s vlan=%[vlan]d from port=%[port]d ip=%[old_ip]I to tunnel=%[tunnel]s ip=%[new_ip]I %[caller]s

11385

mac moved from a port to a tunnel

note

cluster_vlag_l2_update_failed

Updating mac=%[mac]M vnet=%[vnet]s vlan=%[vlan]d from peer update to vlag port port=%[port]d failed, cluster may be out-of-sync: reason=%[reason]s

11386

updating mac to vlag port in response to peer status update failed, cluster L2 may be out of sync

warn

cluster_tunnel_l2_update_failed

Updating mac=%[mac]M vxlan=%[vxlan]d tunnel=%[tunnel]s from peer update failed, cluster may be out-of-sync: reason=%[reason]s

11387

updating tunnel mac in response to peer status update failed, cluster L2 may be out of sync

warn

cluster_comm_l2_update_failed

Updating mac=%[mac]M vnet=%[vnet]s vlan=%[vlan]d from peer update to cluster port port=%[port]d failed, cluster may be out-of-sync: reason=%[reason]s

11388

updating mac to cluster link in response to peer status update failed, cluster L2 may be out of sync

warn

l2_check_bad_tunnel

Fix l2 entry in hardware with incorrect tunnel: mac=%[mac]M %[net]N vxlan=%[vxlan]d old_tunnel=%[old_tunnel]s new_tunnel=%[new_tunnel]s result=%[result]s

11389

Fix layer 2 entry in hardware with incorrect tunnel

warn

l2_check_mismatch_vport

Mismatched vport entry: mac=%[mac]M %[net]N vxlan=%[vxlan]d hw_vlan=%[hw_vlan]d hw_vxlan=%[hw_vxlan]d result=%[result]s

11390

Mismatched vport entry

warn

l2_check_mark_port_mac

Marked vport as port-mac: mac=%[mac]M %[net]N vxlan=%[vxlan]d

11391

Marked owned local vport as port-mac

warn

l2_check_delete_port_mac

Delete invalid port-mac vport: mac=%[mac]M %[net]N vxlan=%[vxlan]d

11392

Delete port-mac that should not be in vport table

warn

hostid_collision_detected

Our hostid is being used by another node %[node_name]s

11393

received keep-alive from another node having same hostid

critical

mirror_to_cpu_configured

Mirror to CPU configured on vFlow %[vflow_name]s

11395

Mirror to CPU configured

note

low_disk_space

Disk Space Usage has exceeded threshold of 70 percent

11396

Disk space usage exceeds 70 percent

warn

stp_vnet_port_recv

received STP BPDU on vnet port: port=%[port]d

11397

received an STP BPDU on a vnet port

warn

igmp_disabled

Disabling IGMP on network: %[net]N

11398

Disabling IGMP on network

note

igmp_enabled

Enabling IGMP on network: %[net]N

11399

Enabling IGMP on network

note

l2_check_hw_invalid

Remove invalid l2 entry from hardware: mac=%[mac]M %[net]N vxlan=%[vxlan]d port=%[port]d tunnel=%[tunnel]s result=%[result]s

11400

Remove invalid layer 2 entry in hardware (incorrect HW entry)

warn

congestion_on_port

Congestion detected on port=%[port]d

11401

Congestion detected on port. Positive icongdrop/ocongdrop

critical

congestion_relieved_on_port

Congestion relieved on port=%[port]d

11402

Congestion relieved on port.

critical

fabric_node_status

%[node_name]s: Node status changed to %[status]s

11403

fabric node state changed

note

mld_disabled

Disabling MLD on vlan: vlan=%[vlan]d

11404

Disabling MLD on vlan

note

mld_enabled

Enabling MLD on vlan: vlan=%[vlan]d

11405

Enabling MLD on vlan

note

vlan_public_id_mismatch

vnet=%[vnet]s vlan=%[vlan]d public-id mismatch while cluster offline

11406

while cluster was offline vlan public-id mismatch happened

error

vlan_port_node_ignored

Ignoring offline cluster node name=%[name]s while assigning public vlan to vnet=%[vnet]s vlan=%[vlan]d

11407

ignored offline cluster for private vlan port assignment

warn

vlan_public_id_fail

failed to set public-vlan for vnet=%[vnet]s vlan=%[vlan]d msg=%[msg]s

11408

failed to set public vlan id while handling cluster status update

error

bad_xcvr_detected

unable to access I2C bus; possible bad transceiver

11409

unable to access I2C bus; possibly a bad transceiver is inserted

error

tacacs_server_error

server=%[server]s TACACS+ authorization disabled due to repeated server errors

11414

Repeated TACACS+ server errors. TACACS+ authorization disabled

critical

tacacs_server_ok

server=%[server]s TACACS+ authorization enabled due to server errors resolved

11415

TACACS+ server has recovered from errors. TACACS+ Authorization enabled

note

dhcp_untrusted_msg

DHCP server message received from untrusted port=%[port]d server-ip=%[ip]I

11416

received DHCP server message from an untrusted port

warn

fabric_guard_loop_detect

Fabric-guard detected a loop on port %[port]d. Port blocked.

11422

Fabric-guard detected loop

note

replace_offline_node

loc-id=%[loc_id]d: node=%[name]s node-id=%[node_id]d replacing old-node=%[old_name]s old-node-id=%[old_node_id]d

11423

new node replacing offline node with the same location id

note

loc_id_conflict

loc-id=%[loc_id]d owned by node=%[name]s node-id=%[node_id]d, ignore message from conflict-node=%[old_name]s conflict-node-id=%[old_node_id]d

11424

two nodes with the same loc-id is not allowed, ignoring latest

warn

ntp_server_sync

NTP server is unresolvable/unreachable

11431

NTP server not resolvable/reachable

critical

xact_rollforward_ignore_error

Transactions rollforward tid=%[tid]d cmd=%[cmd]s failed result=%[result]R, ignoring error

11432

xact rollforward failure overridden by user

warn

xact_rollback_ignore_error

Transactions rollback tid=%[tid]d cmd=%[cmd]s failed result=%[result]R, ignoring error

11433

xact rollback failure overridden by user

warn

nxu_module_fw_upgrade

Installed version: %[inst]s; available version %[avail]s

11434

One or more Lutera xcvrs require module firmware upgrade

warn

nxu_chipset_fw_upgrade

Installed version: %[inst]s; available version %[avail]s

11435

One or more Lutera xcvrs require chipset firmware upgrade

warn

sensor_unavailable

sensor %[name]s cannot be accessed

11436

sensor cannot be read by BMC

warn

ipv6_raguard_ra_port_drop

Dropping RA from port=%[port]d. %[msg]s

11504

Drop RA packet from port according to RA Guard Policy

warn

ipv6_raguard_ra_vlan_drop

Dropping RA from vlan=%[vlan]d. %[msg]s

11505

Drop RA packet from vlan according to RA Guard Policy

warn

disk_health_below_RMA

The disk health level %[current]d is significantly below recommended level %[rma]d, please notify Pluribus TAC immediately

11514

The disk health is below the minimum required to work needs to be RMAed

critical

disk_health_below_minimum

The disk health level %[current]d is below recommended level %[rma]d, please notify Pluribus TAC

11515

The disk health is below the minimum required to work

critical

disk_health_filesystem_readonly

The filesystem %[part]s is in Read Only mode, please notify Pluribus TAC immediately

11516

The disk partition is mounted read-only

critical

SI_setting_update

Changed SI setting for port(s) %[pmap]s to %[cbl_type]s

11517

User has set explicit port cable type

warn

syslog_send_failed

failed to send log message to syslog: server=%[server]s \"err=%[err]m\"

20000

sendto failed. This probably means some sort of resource exhaustion because it's a udp socket we're sending on

error

syslog_hostname_lookup_failed

failed to resolve hostname=%[host]s for syslog server=%[server]s err=\"%[err]m\"

20001

switch may have dns problems, or admin has configured a bogus hostname for syslog server

error

system_repeats

Last %[msgs]d message(s) repeated %[times]d time(s)

20002

compress repeated messages

note

reset_counters

system log counters reset timestamp %[timestamp]s

20005

reset system log counters

note

syslog_tls_server_down

tcp-tls connection to syslog server=%[server]s down. Logs are not getting exported

20006

Connection to syslog export tcp/tls server is down. syslog export to external server is not happening

error

syslog_tls_server_restored

tcp-tls connection to syslog server=%[server]s restored. Log export is operational

20007

Connection to syslog export tcp/tls server is restored.

error

syslog_tls_server_dropped

syslog export log messages to syslog server=%[server]s getting dropped

20008

Syslog export message(s) to tcp/tls server dropped.

error

syslog_tls_server_delayed

syslog export log messages to syslog server=%[server]s getting delayed

20009

Syslog export message(s) to tcp/tls server delayed.

error

generic_platform_audit

platform audit message: %[msg]s

20010

Platform audit message

note

container_log

container log message: %[msg]s

20011

Logs from the containers

note

os_logs

OS audit log message: %[msg]s

20012

Logs from the Operating system auditing

note

mon_start

=== nvOS_mon start ===

30000

nvOS_mon startup

note

mon_exit

exiting because %[reason]s

30001

monitor exiting for some reason

warn

mon_reboot

system reboot

30004

nvOS_mon is rebooting the system

note

mon_restart_nvOSd

monitor restarting nvOSd

30005

restarting nvOSd

note

mon_failure_detected

monitor detected failure %[failure]s

30006

monitor detected a failure

warn

mon_reset

reset nvOSd config

30007

nvOS_mon is resetting nvOSd's configuration

note

mon_grub_gen

regenerating grub configuration for new boot environment

30008

nvOS_mon is re-generating grub

note

mon_restart_tomcat

monitor restarting tomcat

30009

restarting tomcat

note

mon_cpu_usage_high

high cpu usage detected

30010

high cpu usage detected

note

mon_memory_usage_high

high memory usage detected

30011

high memory usage detected

note

mon_disable_ports

nvOSd cannot be revived; disabling ports to prevent headless switching

30012

Monitor failed to restart nvOSd; disabling ports to prevent headless switching

critical

mon_auth_failed

User authorization failed for user %[name]s, pid %[pid]d, ip %[ip]I

30013

user authorization failed

note

mon_keepalive_hung

nvOS_mon is possibly stuck ! %[action]s

30014

nvOS_mon keepalive_checker thread is possibly hung

critical

mon_autoreboot_cancel

%[reason]s; the system will not be rebooted.

30015

System will not be rebooted; auto-reboot is disabled or software-upgrade is in progress.

critical

mon_autoreboot_failed

System failed to auto-reboot: %[reason]s

30016

auto-reboot failed

critical

mon_cpu_usage_higher_than_seventy

CPU usage higher than 70 percent detected

30017

CPU usage higher than 70 percent detected

warn

mon_memory_usage_higher_than_seventy

Memory usage higher than 70 percent detected

30018

Memory usage higher than 70 percent detected

warn

mon_memory_usage_lower_than_sixtyfive

Memory usage is normal, lower than 65(%[mem].2f) percent detected

30019

Memory usage is normal, lower than 65 percent detected

note

fanmon_fan_status

Controller %[controller]d fan %[fan]d speed %[rpm]d RPM

31000

Initial status of a fan

note

fanmon_fan_missing

Controller %[controller]d fan %[fan]d is missing

31001

Fan is missing

warn

fanmon_fan_status_max

Controller %[controller]d fan %[fan]d speed is max

31002

Fan is set to max speed

note

fanmon_fan_fault

Controller %[controller]d fan %[fan]d fault: %[fault]s

31003

Fan fault detected

warn

fanmon_fan_fault_compensate

One fan failed; setting all other fans to max speed

31004

One fan faulted, so setting all other fans to max speed to compensate

warn

fanmon_poweroff

Fan monitor powering down system: %[reason]s

31005

fan monitor powering down system due to faults or overtemp

critical

smf_nvOSd_start

SMF Service starting nvOSd

31007

smf starting nvOSd

note

smf_nvOSd_stop

SMF Service stopping nvOSd

31008

smf stopping nvOSd

note

hw_route_prec0_detected

F64 count=%[count]d hardware routes with invalid precedence detected

31011

Aquila hardware route with invalid precedence detected

critical

fanmon_fan_info

Current temp %[temp]d Current speed %[rpm]d RPM

31015

Show current temperature and Fan Speed setting info

note

hwmon_start

=== nvOSd_hwmon start ===

32000

nvOSd_hwmon startup

note

hwmon_exit

exiting because %[reason]s

32001

hardware monitor exiting for some reason

warn

hwmon_power_supply_fault

power supply %[name]s fault

32002

power supply has failed

critical

hwmon_power_supply_ok

power supply %[name]s has recovered from faulted state

32003

power supply OK

note

hwmon_fan_fault

fan %[name]s fault

32004

fan has failed

critical

hwmon_fan_ok

fan %[name]s has recovered from faulted state

32005

fan ok

note

hwmon_sensor_fault

temperature sensor %[name]s fault

32006

temperature sensor fault

warn

hwmon_sensor_ok

temperature sensor %[name]s has recovered from faulted state

32007

temperature sensor ok

note

hwmon_temp_warning

%[name]s at %[t1]dC, shutdown at %[t2]dC

32008

high temperature warning

warn

hwmon_temp_critical

%[name]s at %[t1]dC, shutdown at %[t2]dC

32009

high temperature critical

critical

hwmon_temp_shutdown

shutting down system: %[name]s at %[t1]dC

32010

high temperature system shutdown

critical

hwmon_shutdown_failed

system high temperature shutdown failed

32011

high temperature system shutdown failed

critical

hwmon_temp_ok

%[name]s at %[t1]dC, temperature ok

32012

temperature OK

note