System Log Messages
Version 5.2.1-5020115686
Identifier |
Message |
Code |
Description |
Severity |
system_drop |
lost %[drops]d %[msgs]s |
10002 |
Unable to deliver system log(s) to nvlogd, so system logs dropped |
|
update_find_server_failed |
Failed to contact update server |
11006 |
Failed to find update server |
warn |
update_wrong_redirect |
Unexpected redirect %[url]s from update server |
11007 |
Got an unexpected redirect from http update server lookup |
warn |
nvOSd_start |
===== nvOSd start: version=%[version]s changeset=%[changeset]s branch=%[branch]s |
11008 |
nvOSd startup |
note |
pkt_alloc_failed |
%[feature]s failed to allocate a send buffer |
11009 |
Failed to allocate a packet for sending from the CPU |
warn |
syscall_failed_critical |
%[feature]s: %[syscall]s failed: %[err]m |
11012 |
A system call failed |
critical |
restart_nvOSd |
Restarting %[exe]s |
11013 |
restarting nvOSd |
note |
restart_nvOSd_failed |
Failed to restart %[exe]s: %[err]m |
11014 |
failed to restart nvOSd |
critical |
nvOSd_init_failed |
nvOSd failed to start: %[feature]s: %[err]m |
11015 |
nvOSd was unable to start |
critical |
loop_detected |
LOOP: mac %[mac]M %[net]N on switch %[old_switch]n port %[old_port]d (%[old_ip]I), also on switch %[new_switch]n port %[new_port]d (%[new_ip]I) %[caller]s |
11016 |
detected an L2 loop |
note |
mac_moved |
MOVING MAC=%[mac]M, vnet=%[vnet]s vlan %[vlan]d from switch %[old_switch]n %[old_port]d (%[old_ip]I) to switch %[new_switch]n %[new_port]d %[new_ip]I %[caller]s |
11017 |
mac moved from one port to another |
note |
simulator_mode |
Failed to init switch hardware |
11018 |
simulator mode entered but not from command line |
critical |
fabric_joined |
Joined fabric %[fabname]s |
11019 |
switch joined a fabric |
note |
fabric_unjoined |
Unjoined fabric %[fabname]s |
11020 |
switch unjoined the fabric |
note |
config_imported |
imported configuration from file %[file]s |
11021 |
imported a new configuration |
note |
stp_switch_enable_failed |
STP failed to initialize for switch hardware |
11028 |
STP initialization for underlying switch hardware failed |
critical |
stp_default_spanning_tree_failed |
STP Failed to Create Default Spanning Tree: vlan=%[vlan]d |
11029 |
Unable to create the Spanning Tree for the default VLAN |
critical |
stp_flow |
STP Failed to install flow(s) for BPDU reception: flow=%[flow]s |
11030 |
Unable to install STP flow(s) for the reception of STP packets |
critical |
stp_worker_thread_failed |
STP failed to create worker thread: vlan=%[vlan]d |
11031 |
STP was unable to create worker thread for Spanning Tree |
critical |
stp_config_failed |
loading and application STP configuration failed. |
11041 |
The loading and application of STP configuration failed |
warn |
stp_set_port_state_failed |
STP Port State Failure: port=%[port]d vlan=%[vlan]d |
11045 |
Unable to set the port state for the port on the vlan |
critical |
stp_trunk_port_state |
STP Set Port State: port=%[port]d vlan=%[vlan]d trunk=%[trunk]d |
11046 |
invalid trunk in use by the spanning tree |
warn |
mcast_switch_init |
igmp/mld snooping unable to initialize switch hardware for groups |
11047 |
igmp/mld was unable to initialize the switch hardware for groups |
critical |
igmp_flow_add |
igmp snooping unable to add flow: flow=%[flow]s |
11048 |
igmp was unable to add a flow for IGMP packet processing |
warn |
igmp_flow_remove |
igmp snooping not able to remove flow: flow=%[flow]s |
11049 |
igmp snooping unable to remove flow for igmp processing |
warn |
igmp_query_start |
igmp snooping unable to start query state machine |
11050 |
igmp was not able to start query state machine |
warn |
igmp_query_stop |
igmp snooping unable to stop query state machine |
11051 |
igmp was not able to stop the query state machine |
warn |
mcast_switch_fini |
igmp/mld snooping unable to halt switch hardware for groups |
11052 |
igmp/mld snooping unable to halt switch hardware for groups |
warn |
igmp_static_load |
igmp snooping unable to load static igmp group |
11053 |
igmp snooping unable to load static igmp group |
warn |
igmp_static_source_load |
igmp snooping unable to load static igmp group source list |
11054 |
igmp snooping unable to load static igmp group source list |
warn |
igmp_flooding |
igmp flooding not enabled |
11055 |
igmp flooding not enabled |
warn |
mcast_group_add_failed |
IGMP/MLD Group Add Failed: vlan=%[vlan]d group=%[group]s |
11071 |
mcast snooping failed to add a group to switch hardware |
warn |
mcast_group_remove_failed |
IGMP/MLD Group Remove Failed: vlan=%[vlan]d group=%[group]s |
11072 |
mcast snooping failed to remove a group from switch hardware |
warn |
software_upgrade_initiated |
nvOS software upgrade initiated for %[verinfo]s |
11073 |
software upgrade initiated; downloading and installing new packages |
note |
software_upgrade_complete |
System and nvOS software upgrade complete: %[verinfo]s |
11074 |
system OS and nvOS software upgrade complete |
note |
software_upgrade_failed |
nvOS software upgrade failed: %[err]s |
11075 |
software upgrade failed |
warn |
system_reboot |
System reboot initiated by nvOSd |
11076 |
system reboot initiated by nvOSd |
note |
system_reboot_failed |
System reboot initiated by nvOSd failed |
11077 |
system reboot initiated by nvOSd failed |
warn |
lldp_agent_create_thread_failed |
LLDP Agent Thread Create Failed: mac=%[mac]s group=%[group]s error=%[error]d |
11079 |
Createion of thread for LLDP Agent failed |
warn |
lldp_flow_add_failed |
LLDP Flow Add Failed: flow=%[flow]s |
11080 |
addling flow for LLDP packet reception failed |
warn |
lldp_flow_remove_failed |
LLDP Flow Remove Failed: flow=%[flow]s |
11081 |
removing flow for LLDP packet reception failed |
warn |
evb_platform_not_supported |
EVB is not supported on this platform: port=%[port]d |
11089 |
EVB not supported on this platform |
warn |
evb_ecp_not_enabled |
EVB ECP Is Not Enabled: port=%[port]d |
11090 |
received EVB TLV with ECP not enabled |
warn |
evb_flow_remove_failed |
EVB Flow Remove Failed: flowstr=%[flowstr]s |
11095 |
unable to remove specified EVB flow |
warn |
lldp_agent_create_failure |
LLDP Agent Create Failed: agent=%[agent]s |
11111 |
Failed to create LLDP Agent for one of three agent addresses |
warn |
stats_log_open_failed |
file=%[file]s: stats log file open failed |
11140 |
Log file open failed |
warn |
container_rebuild_start |
container=%[container]s rebuild is started |
11141 |
container rebuild is started |
note |
container_rebuild_end |
container=%[container]s rebuild is completed |
11142 |
container rebuild is completed |
note |
all_container_rebuild |
all containers are rebuilt |
11143 |
all containers are rebuilt |
note |
loop_broken |
LOOP Broken: port=%[port]d vlan=%[vlan]d mac=%[mac]s ip=%[ip]s |
11180 |
A loop was broken on port/vlan for mac/ip |
|
loop_stp |
LOOP STP: port=%[port]d vlan=%[vlan]d mac=%[mac]s ip=%[ip]s |
11181 |
A loop was detected that STP should have prevented |
warn |
update_auto_upgrade |
PN Cloud initiated software upgrade |
11210 |
update server initiated upgrade |
note |
update_error |
Error message from PN Clould: %[msg]s |
11211 |
update server sent an error message |
warn |
ps_initial_status |
Power supply %[psu]d initial status %[status]s |
11302 |
Power supply initial status |
warn |
fan_initial_status |
Fan %[fan]d initial status %[status]s |
11303 |
Fan initial status |
warn |
ps_status_change |
Power supply %[psu]d changed from %[init_status]s to %[new_status]s |
11304 |
Power supply state change |
warn |
fan_status_change |
Fan %[fan]d changed from %[init_status]s to %[new_status]s |
11305 |
Fan status change |
warn |
fabric_node_duplicate_ip |
Fabric node has the same ip=%[ip]I as the local node, cannot send to it |
11319 |
Fabric node has the same IP as the local node, cannot send to it. |
warn |
upgrade_error |
software upgrade error: %[name]s: %[func]s - %[err]s |
11324 |
Software Upgrade errors |
warn |
upgrade_informational |
software upgrade note: %[name]s: %[func]s - %[info]s |
11325 |
Software Upgrade informational messages |
note |
upgrade_reboot |
System reboot initiated by upgrade agent |
11326 |
system reboot initiated by software upgrade |
note |
upgrade_reboot_failed |
System reboot initiated by upgrade agent failed |
11327 |
system reboot initiated by software upgrade failed |
warn |
openstack_nat_failed |
Failed to setup NAT on the OpenStack controller %[name]s |
11328 |
failed to configure nat for openstack |
warn |
mac_tunnel_to_port |
MOVING MAC=%[mac]M, vnet=%[vnet]s vlan=%[vlan]d from tunnel=%[tunnel]s ip=%[old_ip]I to port=%[port]d ip=%[new_ip]I %[caller]s |
11329 |
mac moved from a tunnel to a port |
note |
mac_port_to_switch |
MOVING MAC=%[mac]M, vlan=%[vlan]d from switch=%[old_sw]s port=%[old_port]d ip=%[old_ip]I to switch=%[new_sw]s port=%[new_port]d ip=%[new_ip]I %[caller]s |
11330 |
mac moved from a port to another switch |
note |
mld_flow_add |
mld snooping unable to add flow: flow=%[flow]s |
11341 |
mld was unable to add a flow for MLD packet processing |
warn |
mld_flow_remove |
mld snooping not able to remove flow: flow=%[flow]s |
11342 |
mld snooping unable to remove flow for mld processing |
warn |
mld_query_start |
mld snooping unable to start query state machine |
11343 |
mld was not able to start query state machine |
warn |
mld_query_stop |
mld snooping unable to stop query state machine |
11344 |
mld was not able to stop the query state machine |
warn |
mld_static_load |
mld snooping unable to load static mld group |
11345 |
mld snooping unable to load static mld group |
warn |
mld_static_source_load |
mld snooping unable to load static mld group source list |
11346 |
mld snooping unable to load static mld group source list |
warn |
xact_node_ignored |
Ignoring offline or out of sync cluster node name=%[name]s for transaction tid=%[tid]d |
11366 |
ignored offline or out of sync cluster node for transaction |
warn |
xact_recover |
Transactions out-of-sync detected, rolled forward from old=%[old]d to new=%[new]d via node=%[node]s |
11367 |
auto-recovered from transactions being out of sync |
warn |
xact_recover_failed |
Transaction auto-recover failed: %[msg]s |
11368 |
auto-recover attempted but failed |
warn |
ip_moved |
Moving ip=%[ip]I from old-mac=%[old_mac]M to new-mac=%[new_mac]M |
11369 |
IP address moved from one mac to another |
note |
software_license_expiring |
software license(s) expiring soon code=%[code]s expires_on=%[expires_on]s |
11370 |
software license(s) expiring |
warn |
software_license_expired |
software license(s) have expired code=%[code]s expired_on=%[expires_on]s |
11371 |
software license(s) have expired |
warn |
l2_check_missing |
Add missing l2 entry to hardware: mac=%[mac]M %[net]N vxlan=%[vxlan]d port=%[port]d tunnel=%[tunnel_name]s result=%[result]s |
11376 |
Add layer 2 entry that was missing in hardware |
warn |
l2_check_bad_port |
Fix l2 entry in hardware with incorrect port: mac=%[mac]M %[net]N vxlan=%[vxlan]d old_port=%[old_port]d new_port=%[new_port]d result=%[result]s |
11377 |
Fix layer 2 entry in hardware with incorrect port |
warn |
l2_check_orphaned |
Remove orphaned l2 entry from hardware: mac=%[mac]M %[net]N vxlan=%[vxlan]d port=%[port]d tunnel=%[tunnel]s result=%[result]s |
11378 |
Remove orphaned layer 2 entry in hardware (not in software table) |
warn |
mac_move_denied |
MOVE DENIED mac=%[mac]M %[net]N from switch=%[sw]n port=%[port]d to deny-switch=%[deny_sw]n deny-port=%[deny_port]d reason=%[reason]s |
11379 |
Mac moved not allowed |
note |
host_port_loop_detected |
Looping traffic detected on switch=%[sw]n local-host-port=%[port]d %[net]N. Traffic on this port/network will be ignored until loop resolved |
11380 |
loop detected on host port |
warn |
host_port_loop_resolved |
Traffic has stopped looping on host-port=%[port]d %[net]N |
11381 |
loop on host port is no longer happening |
note |
owner_mac_moved |
caller=%[caller]s owner=%[owner]n mac=%[mac]M vnet=%[vnet]s vlan=%[vlan]d moved from old-local-port=%[old_port]d to new-local-port=%[new_port]d |
11382 |
other switch's mac moved from one local port to another |
note |
mstp_set_port_state_failed |
STP Port State Failure: port=%[port]d instance=%[instance]d |
11384 |
Unable to set the stp state for the port on the MST instance |
critical |
mac_port_to_tunnel |
MOVING MAC=%[mac]M, vnet=%[vnet]s vlan=%[vlan]d from port=%[port]d ip=%[old_ip]I to tunnel=%[tunnel]s ip=%[new_ip]I %[caller]s |
11385 |
mac moved from a port to a tunnel |
note |
cluster_vlag_l2_update_failed |
Updating mac=%[mac]M vnet=%[vnet]s vlan=%[vlan]d from peer update to vlag port port=%[port]d failed, cluster may be out-of-sync: reason=%[reason]s |
11386 |
updating mac to vlag port in response to peer status update failed, cluster L2 may be out of sync |
warn |
cluster_tunnel_l2_update_failed |
Updating mac=%[mac]M vxlan=%[vxlan]d tunnel=%[tunnel]s from peer update failed, cluster may be out-of-sync: reason=%[reason]s |
11387 |
updating tunnel mac in response to peer status update failed, cluster L2 may be out of sync |
warn |
cluster_comm_l2_update_failed |
Updating mac=%[mac]M vnet=%[vnet]s vlan=%[vlan]d from peer update to cluster port port=%[port]d failed, cluster may be out-of-sync: reason=%[reason]s |
11388 |
updating mac to cluster link in response to peer status update failed, cluster L2 may be out of sync |
warn |
l2_check_bad_tunnel |
Fix l2 entry in hardware with incorrect tunnel: mac=%[mac]M %[net]N vxlan=%[vxlan]d old_tunnel=%[old_tunnel]s new_tunnel=%[new_tunnel]s result=%[result]s |
11389 |
Fix layer 2 entry in hardware with incorrect tunnel |
warn |
l2_check_mismatch_vport |
Mismatched vport entry: mac=%[mac]M %[net]N vxlan=%[vxlan]d hw_vlan=%[hw_vlan]d hw_vxlan=%[hw_vxlan]d result=%[result]s |
11390 |
Mismatched vport entry |
warn |
l2_check_mark_port_mac |
Marked vport as port-mac: mac=%[mac]M %[net]N vxlan=%[vxlan]d |
11391 |
Marked owned local vport as port-mac |
warn |
l2_check_delete_port_mac |
Delete invalid port-mac vport: mac=%[mac]M %[net]N vxlan=%[vxlan]d |
11392 |
Delete port-mac that should not be in vport table |
warn |
hostid_collision_detected |
Our hostid is being used by another node %[node_name]s |
11393 |
received keep-alive from another node having same hostid |
critical |
mirror_to_cpu_configured |
Mirror to CPU configured on vFlow %[vflow_name]s |
11395 |
Mirror to CPU configured |
note |
low_disk_space |
Disk Space Usage has exceeded threshold of 70 percent |
11396 |
Disk space usage exceeds 70 percent |
warn |
stp_vnet_port_recv |
received STP BPDU on vnet port: port=%[port]d |
11397 |
received an STP BPDU on a vnet port |
warn |
igmp_disabled |
Disabling IGMP on network: %[net]N |
11398 |
Disabling IGMP on network |
note |
igmp_enabled |
Enabling IGMP on network: %[net]N |
11399 |
Enabling IGMP on network |
note |
l2_check_hw_invalid |
Remove invalid l2 entry from hardware: mac=%[mac]M %[net]N vxlan=%[vxlan]d port=%[port]d tunnel=%[tunnel]s result=%[result]s |
11400 |
Remove invalid layer 2 entry in hardware (incorrect HW entry) |
warn |
congestion_on_port |
Congestion detected on port=%[port]d |
11401 |
Congestion detected on port. Positive icongdrop/ocongdrop |
critical |
congestion_relieved_on_port |
Congestion relieved on port=%[port]d |
11402 |
Congestion relieved on port. |
critical |
fabric_node_status |
%[node_name]s: Node status changed to %[status]s |
11403 |
fabric node state changed |
note |
mld_disabled |
Disabling MLD on vlan: vlan=%[vlan]d |
11404 |
Disabling MLD on vlan |
note |
mld_enabled |
Enabling MLD on vlan: vlan=%[vlan]d |
11405 |
Enabling MLD on vlan |
note |
vlan_public_id_mismatch |
vnet=%[vnet]s vlan=%[vlan]d public-id mismatch while cluster offline |
11406 |
while cluster was offline vlan public-id mismatch happened |
error |
vlan_port_node_ignored |
Ignoring offline cluster node name=%[name]s while assigning public vlan to vnet=%[vnet]s vlan=%[vlan]d |
11407 |
ignored offline cluster for private vlan port assignment |
warn |
vlan_public_id_fail |
failed to set public-vlan for vnet=%[vnet]s vlan=%[vlan]d msg=%[msg]s |
11408 |
failed to set public vlan id while handling cluster status update |
error |
bad_xcvr_detected |
unable to access I2C bus; possible bad transceiver |
11409 |
unable to access I2C bus; possibly a bad transceiver is inserted |
error |
tacacs_server_error |
server=%[server]s TACACS+ authorization disabled due to repeated server errors |
11414 |
Repeated TACACS+ server errors. TACACS+ authorization disabled |
critical |
tacacs_server_ok |
server=%[server]s TACACS+ authorization enabled due to server errors resolved |
11415 |
TACACS+ server has recovered from errors. TACACS+ Authorization enabled |
note |
dhcp_untrusted_msg |
DHCP server message received from untrusted port=%[port]d server-ip=%[ip]I |
11416 |
received DHCP server message from an untrusted port |
warn |
fabric_guard_loop_detect |
Fabric-guard detected a loop on port %[port]d. Port blocked. |
11422 |
Fabric-guard detected loop |
note |
replace_offline_node |
loc-id=%[loc_id]d: node=%[name]s node-id=%[node_id]d replacing old-node=%[old_name]s old-node-id=%[old_node_id]d |
11423 |
new node replacing offline node with the same location id |
note |
loc_id_conflict |
loc-id=%[loc_id]d owned by node=%[name]s node-id=%[node_id]d, ignore message from conflict-node=%[old_name]s conflict-node-id=%[old_node_id]d |
11424 |
two nodes with the same loc-id is not allowed, ignoring latest |
warn |
ntp_server_sync |
NTP server is unresolvable/unreachable |
11431 |
NTP server not resolvable/reachable |
critical |
xact_rollforward_ignore_error |
Transactions rollforward tid=%[tid]d cmd=%[cmd]s failed result=%[result]R, ignoring error |
11432 |
xact rollforward failure overridden by user |
warn |
xact_rollback_ignore_error |
Transactions rollback tid=%[tid]d cmd=%[cmd]s failed result=%[result]R, ignoring error |
11433 |
xact rollback failure overridden by user |
warn |
nxu_module_fw_upgrade |
Installed version: %[inst]s; available version %[avail]s |
11434 |
One or more Lutera xcvrs require module firmware upgrade |
warn |
nxu_chipset_fw_upgrade |
Installed version: %[inst]s; available version %[avail]s |
11435 |
One or more Lutera xcvrs require chipset firmware upgrade |
warn |
sensor_unavailable |
sensor %[name]s cannot be accessed |
11436 |
sensor cannot be read by BMC |
warn |
ipv6_raguard_ra_port_drop |
Dropping RA from port=%[port]d. %[msg]s |
11504 |
Drop RA packet from port according to RA Guard Policy |
warn |
ipv6_raguard_ra_vlan_drop |
Dropping RA from vlan=%[vlan]d. %[msg]s |
11505 |
Drop RA packet from vlan according to RA Guard Policy |
warn |
disk_health_below_RMA |
The disk health level %[current]d is significantly below recommended level %[rma]d, please notify Pluribus TAC immediately |
11514 |
The disk health is below the minimum required to work needs to be RMAed |
critical |
disk_health_below_minimum |
The disk health level %[current]d is below recommended level %[rma]d, please notify Pluribus TAC |
11515 |
The disk health is below the minimum required to work |
critical |
disk_health_filesystem_readonly |
The filesystem %[part]s is in Read Only mode, please notify Pluribus TAC immediately |
11516 |
The disk partition is mounted read-only |
critical |
SI_setting_update |
Changed SI setting for port(s) %[pmap]s to %[cbl_type]s |
11517 |
User has set explicit port cable type |
warn |
syslog_send_failed |
failed to send log message to syslog: server=%[server]s \"err=%[err]m\" |
20000 |
sendto failed. This probably means some sort of resource exhaustion because it's a udp socket we're sending on |
error |
syslog_hostname_lookup_failed |
failed to resolve hostname=%[host]s for syslog server=%[server]s err=\"%[err]m\" |
20001 |
switch may have dns problems, or admin has configured a bogus hostname for syslog server |
error |
system_repeats |
Last %[msgs]d message(s) repeated %[times]d time(s) |
20002 |
compress repeated messages |
note |
reset_counters |
system log counters reset timestamp %[timestamp]s |
20005 |
reset system log counters |
note |
syslog_tls_server_down |
tcp-tls connection to syslog server=%[server]s down. Logs are not getting exported |
20006 |
Connection to syslog export tcp/tls server is down. syslog export to external server is not happening |
error |
syslog_tls_server_restored |
tcp-tls connection to syslog server=%[server]s restored. Log export is operational |
20007 |
Connection to syslog export tcp/tls server is restored. |
error |
syslog_tls_server_dropped |
syslog export log messages to syslog server=%[server]s getting dropped |
20008 |
Syslog export message(s) to tcp/tls server dropped. |
error |
syslog_tls_server_delayed |
syslog export log messages to syslog server=%[server]s getting delayed |
20009 |
Syslog export message(s) to tcp/tls server delayed. |
error |
generic_platform_audit |
platform audit message: %[msg]s |
20010 |
Platform audit message |
note |
container_log |
container log message: %[msg]s |
20011 |
Logs from the containers |
note |
os_logs |
OS audit log message: %[msg]s |
20012 |
Logs from the Operating system auditing |
note |
mon_start |
=== nvOS_mon start === |
30000 |
nvOS_mon startup |
note |
mon_exit |
exiting because %[reason]s |
30001 |
monitor exiting for some reason |
warn |
mon_reboot |
system reboot |
30004 |
nvOS_mon is rebooting the system |
note |
mon_restart_nvOSd |
monitor restarting nvOSd |
30005 |
restarting nvOSd |
note |
mon_failure_detected |
monitor detected failure %[failure]s |
30006 |
monitor detected a failure |
warn |
mon_reset |
reset nvOSd config |
30007 |
nvOS_mon is resetting nvOSd's configuration |
note |
mon_grub_gen |
regenerating grub configuration for new boot environment |
30008 |
nvOS_mon is re-generating grub |
note |
mon_restart_tomcat |
monitor restarting tomcat |
30009 |
restarting tomcat |
note |
mon_cpu_usage_high |
high cpu usage detected |
30010 |
high cpu usage detected |
note |
mon_memory_usage_high |
high memory usage detected |
30011 |
high memory usage detected |
note |
mon_disable_ports |
nvOSd cannot be revived; disabling ports to prevent headless switching |
30012 |
Monitor failed to restart nvOSd; disabling ports to prevent headless switching |
critical |
mon_auth_failed |
User authorization failed for user %[name]s, pid %[pid]d, ip %[ip]I |
30013 |
user authorization failed |
note |
mon_keepalive_hung |
nvOS_mon is possibly stuck ! %[action]s |
30014 |
nvOS_mon keepalive_checker thread is possibly hung |
critical |
mon_autoreboot_cancel |
%[reason]s; the system will not be rebooted. |
30015 |
System will not be rebooted; auto-reboot is disabled or software-upgrade is in progress. |
critical |
mon_autoreboot_failed |
System failed to auto-reboot: %[reason]s |
30016 |
auto-reboot failed |
critical |
mon_cpu_usage_higher_than_seventy |
CPU usage higher than 70 percent detected |
30017 |
CPU usage higher than 70 percent detected |
warn |
mon_memory_usage_higher_than_seventy |
Memory usage higher than 70 percent detected |
30018 |
Memory usage higher than 70 percent detected |
warn |
mon_memory_usage_lower_than_sixtyfive |
Memory usage is normal, lower than 65(%[mem].2f) percent detected |
30019 |
Memory usage is normal, lower than 65 percent detected |
note |
fanmon_fan_status |
Controller %[controller]d fan %[fan]d speed %[rpm]d RPM |
31000 |
Initial status of a fan |
note |
fanmon_fan_missing |
Controller %[controller]d fan %[fan]d is missing |
31001 |
Fan is missing |
warn |
fanmon_fan_status_max |
Controller %[controller]d fan %[fan]d speed is max |
31002 |
Fan is set to max speed |
note |
fanmon_fan_fault |
Controller %[controller]d fan %[fan]d fault: %[fault]s |
31003 |
Fan fault detected |
warn |
fanmon_fan_fault_compensate |
One fan failed; setting all other fans to max speed |
31004 |
One fan faulted, so setting all other fans to max speed to compensate |
warn |
fanmon_poweroff |
Fan monitor powering down system: %[reason]s |
31005 |
fan monitor powering down system due to faults or overtemp |
critical |
smf_nvOSd_start |
SMF Service starting nvOSd |
31007 |
smf starting nvOSd |
note |
smf_nvOSd_stop |
SMF Service stopping nvOSd |
31008 |
smf stopping nvOSd |
note |
hw_route_prec0_detected |
F64 count=%[count]d hardware routes with invalid precedence detected |
31011 |
Aquila hardware route with invalid precedence detected |
critical |
fanmon_fan_info |
Current temp %[temp]d Current speed %[rpm]d RPM |
31015 |
Show current temperature and Fan Speed setting info |
note |
hwmon_start |
=== nvOSd_hwmon start === |
32000 |
nvOSd_hwmon startup |
note |
hwmon_exit |
exiting because %[reason]s |
32001 |
hardware monitor exiting for some reason |
warn |
hwmon_power_supply_fault |
power supply %[name]s fault |
32002 |
power supply has failed |
critical |
hwmon_power_supply_ok |
power supply %[name]s has recovered from faulted state |
32003 |
power supply OK |
note |
hwmon_fan_fault |
fan %[name]s fault |
32004 |
fan has failed |
critical |
hwmon_fan_ok |
fan %[name]s has recovered from faulted state |
32005 |
fan ok |
note |
hwmon_sensor_fault |
temperature sensor %[name]s fault |
32006 |
temperature sensor fault |
warn |
hwmon_sensor_ok |
temperature sensor %[name]s has recovered from faulted state |
32007 |
temperature sensor ok |
note |
hwmon_temp_warning |
%[name]s at %[t1]dC, shutdown at %[t2]dC |
32008 |
high temperature warning |
warn |
hwmon_temp_critical |
%[name]s at %[t1]dC, shutdown at %[t2]dC |
32009 |
high temperature critical |
critical |
hwmon_temp_shutdown |
shutting down system: %[name]s at %[t1]dC |
32010 |
high temperature system shutdown |
critical |
hwmon_shutdown_failed |
system high temperature shutdown failed |
32011 |
high temperature system shutdown failed |
critical |
hwmon_temp_ok |
%[name]s at %[t1]dC, temperature ok |
32012 |
temperature OK |
note |