vport-create

This command is used to create a virtual port on a switch. Virtual ports track information across nodes on the fabric.

Syntax   vport-create

mac mac-address

Specify the MAC address of the vPort.

Specify up to two of the following options:

vlan vlan-id

Specify a VLAN from 0 to 4095.

vxlan vxlan-id

Specify a VXLAN from 0 to 16777215.

vnet vnet-name

Specify a VNET assigned to the vPort.

Specify at least one of the following options:

ip ip-address

Specify an IP address.

owner node-name

Specify the switch ID.

intf intf-number

Specify the interface number.

Specify any of the following options:

public-vlan vlan-id

Specify the ID of the public VLAN.

num-ips num-ips-number

Specify the number of IP addresses for the vPort.

config-intf config-intf-number

Specify the configuration interface number.

svc-name svc-name-string

Specify the vCenter connection service name.

hostname hostname-string

Specify the host name of the switch.

entity entity-string

Specify the VM or VM Kernel device name.

power none|powered-off|powered-on|standby|suspended|unknown

Specify the vPort entry power status.

cpus cpus-number

Specify the number of CPUs assigned to the VM.

disk disk-number

Specify the disk number of the VM location.

os os-string

Specify an operating system, such as CentOS or Ubuntu, on the VM.

portgroup portgroup-string

Specify the Port Group name associated with VM MAC address.

pg-vlans vlan-list

Specify the valid VLANs for the port group.

vswitch vswitch-string

Specify the vitual switch name associated with the NIC.

vs-type none|host-vs|distributed-vs|unknown

Specify the virtual switch type.

vnic-type untagged|tagged|trunked|vm-mgmt|vm-kernel|vMotion|vSAN|FTL|rep|p-NFC|r-NFC|mgmt|unknown

Specify the type of vNIC attached to the VM or VM Kernel.

rem-switch node-name

Specify the remote switch for the vPort.

hw-index hw-index-number

Specify the hardware index number.

rt-if rt-if-string

Specify the router interface.

hw-flags invalid-vlan|invalid-port

Specify the vPort hardware flags.

Defaults   None

Access   CLI

History   

Version 2.2

Command introduced.

Version 2.3

The parameters, num-ips and vm-status, added.

Version 2.3.1

The parameter, switch-id, changed to owner.

Version 2.4

The parameters, hw-index and rt-if, added.

Version 2.4.1

The parameters, vnet, hw-flags, and public-vlan, added. The parameter, blocked-ports, deprecated.

Version 2.6.2

The parameter, svc-name, power, entity, portgroup, pg-vlans, vswitch, vs-type, and vnic-type, added.

The parameters, hypervisor, vm-id, vm-name, vm-flavor, vm-status, memory, deprecated.

Usage   Use this command to create a vPort on the switch. vPorts are mirrored across the fabric so that every switch knows about all the L2 entries on the fabric. This is useful for troubleshooting connections across the fabric.

Examples  To configure a vPort with the MAC address of 06:60:00:02:10:38, IP address of 192.168.11.11, on VLAN 107, use the following syntax:

CLI network-admin@switch > vport-create mac 06:60:00:02:10:38 vlan 107 ip 192.168.11.11

vport-delete

This command is used to delete a virtual port on a switch. Virtual ports track information across nodes on the fabric.

Syntax   vport-delete mac mac-address vlan vlan-id vxlan vxlan-id ip ip-address 

mac mac-address

Specify the MAC address of the vPort to delete from the configuration.

vnet vnet-name

Specify a VNET assigned to the vPort.

vlan vlan-id

Specify the VLAN ID of the vPort to delete from the configuration.

vxlan vxlan-id

Specify the VXLAN ID of the vPort to delete from the configuration.

ip ip-address

Specify the IP address of the vPort to delete from the configuration.

Defaults   None

Access   CLI

History   

Version 2.2

Command introduced.

Version 2.4.1

The parameter, vnet, added.

Usage   Use this command to remove a vPort from the configuration.

Examples  To remove the vPort with the IP address, 192.168.11.9, use the following command:

CLI network-admin@switch > vport-delete ip 192.168.11.9

vport-history-show

This command is used to display historical information about virtual ports on a fabric. Virtual ports track information about servers, virtual machines, and switches in a fabric.

Informational Note:  Netvisor does not automatically populate the output fields for hypervisor and VM. In future releases, Netvisor gathers this information using a multicast communication across the fabric.

Syntax   vport-history-show

time date/time: yyyy-mm-ddThh:mm:ss

Specifies a point in tjme for displaying historical information.

start-time date/time: yyyy-mm-ddThh:mm:ss

Specifies the start time for vPort history collection.

end-time date/time: yyyy-mm-ddThh:mm:ss

Specifies the end time for vPort history collection.

duration duration: #d#h#m#s

Specifies the duration to collect the vPort history.

interval duration: #d#h#m#s

Specifies the intervals to collects vPort history.

since-start

Specifies to display all of the vPort history since collection began on the fabric.

older-than duration: #d#h#m#s

Specifies to display vPort information older than a specific duration.

within-last duration: #d#h#m#s

Specifies to display vPort information with a specific duration.

log-type l2-save|l3-save|restart|l2-modify|l2-delete|l3-modify|
l3-delete

Filter output by the log type of each entry. The log-type column displays when a vPort is created, modified, saved, or deleted.

[caller init|config|status|switch-cb|cluster|gre|ARP|router|flow-cb|vdp|vlag|port|inject|evict|vxlan|stats|vnm-vnic|adjacency|stp|trunk|intsw|ttl1|flood|flush|retire|loop|dhcp|fabric|table|l3-age-out|vlan|l2-checker|
igmp|l2-age-out|port-mirror|mac-move|cluster-status|cluster-status-delete|vxlan-routing|                subnet|br-dom|vrf|ND

Specifies the feature that made the change for this entry.

[last-caller init|config|status|switch-cb|cluster|gre|ARP|router| flow-cb|vdp|vlag|port|inject|evict|vxlan|stats|vnm-vnic| adjacency|stp|trunk|intsw|ttl1|flood|flush|retire|loop|dhcp| fabric|table|l3-age-out
|vlan|l2-checker|igmp|l2-age-out|port-mirror|mac-move|cluster-status

Specifies the most recent caller for this entry.

[reason activate|deactivate|port-move|
ip-move|ip-remove|batch-move|timeoutretire|break-loop|break-loop-timeout|create|modify|delete|policy|owner-status|remove-node|port-flags|
check-owner|trunk-port-add|
trunk-port-remove|move-router-if|age-out|hw-remove|restart|undo|flush|update-vxlan-vlan|needs-peer-status|
owner-lost|owner-change

Specifies the reason for history entry.

last-reason activate|deactivate|port-move|ip-move|ip-remove|batch-move|retire|break-loop|break-loop-timeout|create|modify|delete|policy|owner-status|remove-node|port-flags|check-owner|trunk-port-add|trunk-port-remove|move-router-if|age-out|hw-remove|restart|undo|flush|update-vxlan-vlan|needs-peer-status|owner-lost|owner-change

Specifies most recent reason for this entry.

changes owner|mac|ip|num-ips|config-intf|intf|ports|state|local-intf|local-ports|local-state|alt-owner|
alt-owner-port|alt-owner-ports|
alt-owner-state|hostname|hypervisor|vm-id|vm-name|vm-flavor|vm-status|memory|cpus|disk|os|config|rem-switch|rem-intf|rem-ports|peer-intf|peer-state|peer-owner-state|status|tunnel|create-time|last-seen|vxlan-lru|hit|
migrate|drops|hw-index|rt-if|
hw-flags

Specifies what changed in this entry.

count count-number

Filter output by the number of entries summed using the sum-by argument.

owner node-name

the switch-id of the vPort.

mac mac-address

Filter output by the Filter output by MAC address.

vlan vlan-id

Filter output by the VLAN ID.

vxlan vxlan-id

Filter output by the VXLAN ID.

vnet vnet-name

Specify the VNET assigned to the vPort.

public-vlan vlan-id

Specify the ID of the public VLAN.

ip ip-address

Filter output by the IP address.

num-ips num-ips-number

Specify the number of IP addresses for the vPort.

intf intf-number

Filter output by the interface number. This is the port or trunk number of the vPort.

config-intf config-intf-number

Filter output by the configured interface of the vPort.

ports port-list

Filter output by the list of ports.

state active|static|vrrp|tunnel|software|needs-peer-status|port-mac|hit|ageout-check|moving|loop-probe|local-tunnel|igmp-mac|user-flush|vxlan-loopback|router

Filter output by the state of the vPort.

svc-name svc-name-string

Specify the vCenter connection service name.

hostname hostname-string

Specify the host name of the switch.

entity entity-string

Specify the VM or VM Kernel device name.

power none|powered-off|powered-on|standby|suspended|unknown

Specify the vPort entry power status.

cpus cpus-number

Filter output by the number of CPUs assigned to the VM.

os os-string

Filter output by the OS installed on the VM.

portgroup portgroup-string

Specify the Port Group name associated with VM MAC address.

pg-vlans vlan-list

Specify the valid VLANs for the port group.

vswitch vswitch-string

Specify the vitual switch name associated with the NIC.

vs-type none|host-vs|distributed-vs|unknown

Specify the virtual switch type.

vnic-type untagged|tagged|trunked|vm-mgmt|vm-kernel|vMotion|vSAN|FTL|rep|p-NFC|r-NFC|mgmt|unknown

Specify the type of vNIC attached to the VM or VM Kernel.

rem-switch node-name

Filter output by the remote switch name.

rem-intf rem-intf-number

Filter output by the remote interface number.

rem-ports port-list 

Filter output by the remote ports.

peer-intf peer-intf-number 

Filter output by the peer interface.

peer-state active|static|vrrp|tunnel|software|needs-peer-status|port-mac|hit|ageout-check|moving|loop-probe|local-tunnel|igmp-mac|user-flush|vxlan-loopback|router

Filter output by peer-state

peer-owner-state active|static|vrrp|tunnel|software|needs-peer-status|port-mac|hit|ageout-check|moving|loop-probe|local-tunnel|igmp-mac|user-flush|vxlan-loopback|router

Filter output by owner state.

status hy-up|up|disabled|hw-nat-loop|mirror-loop|mirror-to|inuse|PN-switch|PN-fabric|PN-other|PN-cluster|PN-internal|PN-hypervisor|PN-guest|snmp-host|host|uplink|drop-pkts|no-pktin|no-fwd|no-flood|STP-BPDUs|LLDP|trunk|l3-port|remote-l3-port|vdp|dhcp|dhcpsvr|blocked|no-BPDU|LACP-PDUs|vlag-active|vlag-blocked|stp-edge-port|LACP-wait|LACP-fallback|adjacency-wait|adjacency-check|vlag-wait|multicast-router|host-disabled|loop|vxlan-loopback|
vlan-up|ND

Filter output by the status of the vPort.

vtep-ip ip-address

Displays the VTEP IP address.

tunnel tunnel-string 

Specifies the vPort tunnel.

create-time date/time: yyyy-mm-ddThh:mm:ss

Filter output by the time that the vPort was created.

last-seen date/time: yyyy-mm-ddThh:mm:s

Filter output by the time that the vPort was last seen on the fabric.

vxlan-lru date/time: yyyy-mm-ddTHH:mm:ss

Filter output by the VXLAN LRU.

hit hit-number

Filter output by the number of received hits.

migrate migrate-number

Filter output by the number of times that the vPort migrated on the fabric.

drops drops-number

Filter output by the number of drops on the fabric.

hw-index hw-index-number

Filter by the hardware index.

rt-if rt-if-string

Filter by the router interface.

hw-flags invalid-vlan|invalid-port

Filter by hardware flags.

Defaults   None

Access   CLI

History   

Version 2.2

Command introduced.

Version 2.2.6

The parameters, stp-edge-port|LACP-wait| adjacency-wait|adjacency-check|vlag-wait|multicast-router, added.

Version 2.3

The parameters, num-ips and vm-status, added.

Version 2.3.1

The parameters, caller, last-call, reason, last-reason, and changes added.

Version 2.4

The options, l3-modify, l3-save, and l3-delete, added to log-type. The parameters, peer-intf, peer-state, and peer-owner-state added.

Version 2.4.1

The parameters, vnet and public-vlan, added. The options, retire|break-loop|break-loop-timeout, added to the parameter reason. The options vxlan-loopback|router, added to the parameter, state. The parameters, hw-index, rt-if, and hw-flags, added.

Version 2.6.2

The parameter, svc-name, power, entity, portgroup, pg-vlans, vswitch, vs-type, and vnic-type, added.

The parameters, hypervisor, vm-id, vm-name, vm-flavor, vm-status, memory, deprecated.

Version 3.1.0

The parameters, vtep-ip and ND, added.

Usage   Use this command to display vPort history on the switch. vPorts are mirrored across the fabric so that every switch knows about all the L2 entries on the fabric. This is useful for troubleshooting connections across the fabric.

Examples  To display vPort history, with the parameter since-start, use the following syntax:

CLI network-admin@switch > vport-history-show since-start format all layout vertical

time:         09-10,15:17:03

log-type:     l2-modify

switch-id:    pleaides24

mac:          64:0e:94:28:03:3e

vlan:         1

intf:         65

ports:        65

local-intf:   65

local-ports:  65

create-time:  09-10,15:17:06

time:         09-10,15:17:06

log-type:     l2-modify

switch-id:    pleaides24

mac:          64:0e:94:28:03:3e

vlan:         1

intf:         65

ports:        65

state:        active

local-intf:   65

local-ports:  65

local-state:  active

create-time:  09-10,15:17:06

last-seen:    09-10,15:17:06

hit:          1

time:         09-10,15:17:07

log-type:     l2-modify

vport-modify

This command is used to modify a virtual port on a switch. Virtual ports track information across nodes on the fabric.

Syntax   vport-modify

mac mac-address

Specify the MAC address of the vPort.

vlan vlan-id

Specify a VLAN from 0 to 4095.

vxlan vxlan-id

Specify a VLAN from 0 to 16777215.

vnet vnet-name

Specify a VNET assigned to the vPort.

ip ip-address

Specify the IP address of the vPort.

Specify any of the following options:

owner node-name

Specify the switch ID.

public-vlan vlan-id

Specify the ID of the public VLAN.

num-ips num-ips-number

Specify the number of IP addresses for the vPort.

intf intf-number

Specify the interface number.

config-intf config-intf-number

Specify the configuration interface number.

svc-name svc-name-string

Specify the vCenter connection service name.

hostname hostname-string

Specify the host name of the switch.

entity entity-string

Specify the VM or VM Kernel device name.

power none|powered-off|powered-on|standby|suspended|unknown

Specify the vPort entry power status.

cpus cpus-number

Specify the number of CPUs assigned to the VM.

disk disk-number

Specify the disk number of the VM location.

os os-string

Specifies an operating system, such as CentOS or Ubuntu, on the VM.

rem-switch node-name

Specify the remote switch for the vPort.

hw-index hw-index-number

Specify the hardware index number.

rt-if rt-if-string

Specify the router interface.

hw-flags invalid-vlan|invalid-port

Specify the hardware flags.

Defaults   None

Access   CLI

History   

Version 2.2

Command introduced.

Version 2.3

The parameters, num-ips and vm-status, added.

Version 2.4

The parameters, hw-index and rt-if, added.

Version 2.4.1

The parameters, vnet, hw-flags, and public-vlan, added. The parameter, blocked-ports, deprecated.

Version 2.6.2

The parameter, svc-name, power, entity, portgroup, pg-vlans, vswitch, vs-type, and vnic-type, added.

The parameters, hypervisor, vm-id, vm-name, vm-flavor, vm-status, memory, deprecated.

Usage   Use this command to modify a vPort configuration on the switch. vPorts are mirrored across the fabric so that every switch knows about all the L2 entries on the fabric. This is useful for troubleshooting connections across the fabric.

Examples  To modify a vPort with the MAC address of 06:60:00:02:10:38, IP address of 192.168.11.11, and change the VLAN to 107, use the following syntax:

CLI network-admin@switch > vport-modify mac 06:60:00:02:10:38 vlan 107 ip 192.168.11.11

vport-show

This command is used to display information about virtual ports on a fabric. Virtual ports track switch information across nodes on the fabric.

Informational Note:  Netvisor does not automatically populate the output fields for hypervisor and VM. In future releases, Netvisor gathers this information using a multicast communication across the fabric.

Syntax   vport-show

owner node name 

Displays the owner name.

mac mac-address

Displays the MAC address of the vPort.

vnet vnet-name

Displays the VNET name.

Specify up to two of the following options:

vlan vlan-id

Displays a VLAN from 0 to 4095.

public-vlan vlan-id

Displays the ID of the public VLAN.

vxlan vxlan-id

Displays a VXLAN from 0 to 16777215.

ip ip-address

DisplaysDisplays an IP address.

num-ips num-ips-number

Displays the number of IP addresses for the vPort.

Displays any of the following options:

config-intf config-intf-number

Displays the configuration interface number.

ports port-list

Displays the list of ports.

state active|static|vrrp|tunnel|software|needs-peer-status|port-mac|hit|ageout-check|moving|loop-probe|local-tunnel|igmp-mac|user-flush|vxlan-loopback|router|update-peer-only|active-state-mismatch|peer-port-missing|peer-port-not-vlag|peer-port-not-orphaned|peer-port-not-cluster-link|
sw-active|anycast|hsrp|
invalid-vlan|owner-lost

Displays the vPort state.

svc-name svc-name-string

Displays the name of the vCenter connection service.

hostname hostname-string

Displays the hypervisor or switch host name.

entity entity-string

Displays the VM or KVM device name.

power none|powered-off|powered-on|
standby|suspended|unknown

Displays the vPort entry status.

cpus cpus-number

Displays the number of CPUs assigned to the VM.

os os-string

Displays an operating system, such as CentOS or Ubuntu, on the VM.

portgroup portgroup-string

Displays the port group name associated with the VM MAC address.

pg-vlans vlan-list

Displays the VLANs assigned to a port group.

vswitch vswitch-string

Displays the name of the virtual switch associated with a NIC.

vs-type none|host-vs|distributed-vs|
unknown

Displays the type of virtual switch.

vnic-type untagged|tagged|trunked|vm-mgmt|vm-kernel|vMotion|vSAN|FTL|    rep|p-NFC|r-NFC|mgmt|unknown

Displays the type of vNIC associated with the VM or VM-Kernel.

config none|owner|ip|port|hostname|entity|cpus|os

Displays the configuration type for the virtual switch.

rem-switch node name

Displays the name of the remote switch.

rem-intf rem-intf-number

Displays the remote interface number.

rem-ports port-list

Displays the remote switch ports.

peer-intf peer-intf-number

Displays the peer interface number.

peer-state active|static|vrrp|tunnel|software|needs-peer-status|port-mac|hit|ageout-check|moving|loop-probe|local-tunnel|igmp-mac|user-flush|vxlan-loopback|router|update-peer-only|active-state-mismatch|peerport-missing|peer-port-not-vlag|peer-port-not orphaned|peer-port-not-cluster-links|sw-active|anycast|
hsrp||invalid-vlan|
owner-lost

Displays the state of the peer vPorts.

peer-owner-state active|static|vrrp|tunnel|software|needs-peer-status|port-mac|hit|ageout-check|moving|loop-probe|local-tunnel|igmp-mac|user-flush|vxlan-loopback|router|update-peer-only|active-state-mismatch|peerport-missing|peer-port-not-vlag|peer-port-not orphaned|peer-port-not-cluster-links|sw-active|anycast|
hsrp|invalid-vlan|owner-lost

Displays the state of the peer owner vPorts.

status phy-up|up|disabled|hw-nat-loop|mirror-loop|mirror-to|inuse|   PN-switch|PN-fabric|PN-other|PN-cluster|PN-internal|PN-hypervisor|PN-guest|snmp-host|host|uplink|drop-pkts|no-pktin|no-fwd|no-flood|STP-BPDUs|LLDP|trunk|l3-port|remote-l3-port|vdp|dhcp|dhcpsvr|blocked|no-BPDU|LACP-PDUs|vlag-active|vlag-blocked|
stp-edge-port|LACP-wait|
LACP-fallback|adjacency-wait|
adjacency-check|vlag-wait|multicast-router|host-disabled|loop|vxlan-loopback|vlan-up|vle|vle-wait|phy-down|down|enabled|err-bpdu-guard|mac-violation|stp-bpdu-guard|stp-root-guard|ND

Displays the vPort status.

vtep-ip ip-address

Displays the VTEP IP address.

tunnel tunnel-string

Displays the vPort tunnel.

create-time date/time: yyyy-mm-ddTHH:mm:ss

Displays the vPort create time.

last-seen date/time: yyyy-mm-ddTHH:mm:ss

Displays the last time the vPorts was seen.

vxlan-lru date/time: yyyy-mm-ddTHH:mm:ss

Displays the time and date of the VXLAN LRU.

hit hit-number

Displays the number of hits.

migrate migrate-number

Displays the number of times the entry migrated.

drops drops-number

Displays the number of dropped packets.

hw-index hw-index-number

Displays the hardware index number.

rt-if rt-if-string

Displays the router interface.

hw-flags invalid-vlan|invalid-port

Displays hardware flags.

Defaults   None

Access   CLI

History   

Version 2.2

Command introduced.

Version 2.2.6

The parameters, stp-edge-port|LACP-wait| adjacency-wait|adjacency-check|vlag-wait|multicast-router, added.

Version 2.3

The parameters, num-ips and vm-status, added.

Version 2.4.1

The parameter, public-vlan, added.

Version 2.6.2

The parameter, svc-name, power, entity, portgroup, pg-vlans, vswitch, vs-type, and vnic-type, added.

The parameters, hypervisor, vm-id, vm-name, vm-flavor, vm-status, memory, deprecated.

Version 3.0.0

The options, anycast, invalid-vlan, and owner-lost, added to state, peer-state, and peer-owner-state.

Version 3.1.0

The parameters, vtep-ip and ND, added.

Usage   Use this command to display vPort information on the switch. Netvisor mirrors vPorts  across the fabric so every switch knows about all the L2 entries on the fabric. You may find this useful for troubleshooting connections across the fabric.

Examples  To display vPorts, use the following syntax:

CLI network-admin@switch > vport-show format all layout vertical

mac:          66:0e:94:21:64:74

vlan:         103

config-intf:  70

config:       port

switch-id:    pleiades24

mac:          00:00:5e:00:01:0a

vlan:         107

config:       switch

rem-switch:   pleiades25

switch-id:    pleiades25

mac:          66:0e:94:21:a9:6c

vlan:         100

ip:           192.168.11.4

intf:         65

ports:        65

state:        active

hostname:     pleiades25

status:       PN-internal

create-time:  09-10,15:17:47

last-seen:    09-15,10:55:22

hit:          2

migrate:      1

switch-id:    pleiades24

mac:          66:0e:94:21:64:74

vlan:         100

ip:           192.168.100.12

intf:         65

ports:        65

hostname:     pleiades24

status:       PN-internal

create-time:  09-10,15:17:48

last-seen:    09-10,15:17:48

hit:          1

switch-id:    pleiades24

vport-settings-modify

vPort information is collected and stored on a disk on the switch at specific intervals. This command is used to modify the vPort settings.

Syntax   vport-settings-modify

Specify one or more of the following options:

vport-disk-space vport-disk-space-number

Specify the amount of disk space for vPorts. The default is 500M.

stats-max-memory stats-max-memory-number

Specify the maximum memory for collecting vPort information. The default memory is 50M.

stats-log-enable|
stats-log-disable

Specify if you want to enable or disable logs for vPort statistics. Enabled by default.

stats-log-interval duration: #d#h#m#s

Specify the interval between logging events. The default is one minute.

stats-log-disk-space disk-space-number

Specify the amount of disk space for vPort logs. The default is 50M.

system-stats-log-enable|system-stats-log-
disable

Specify if you want to enable or disable logging for the system. Enabled by default.

system-stats-log-
interval duration: #d#h#m#s 

Specify the interval between logging events. The default is one minute.

system-stats-log-disk-
space disk-space-number

Specify the disk space for system statistics. The default is 50M.

Defaults   See individual parameters.

Access   CLI

History   Command introduced in nvOS Version 2.2.

Usage   Use the command to modify vPort settings to collect vPort information.

Examples  To modify the vPort disk space from 500M to 1G, use the following syntax:

CLI network-admin@switch > vport-settings-modify vport-disk-space 1G

vport-settings-show

Netvisor collects and stores vPort information on a disk on the switch at specific intervals. This command is used to display the vPort settings.

Syntax   vport-settings-show


Defaults   See individual parameters.

Access   CLI

History   Command introduced in nvOS Version 2.2.

Usage   Use the command to display vPort settings for collecting vPort information.

Examples  To display vPort settings, use the following syntax:

CLI network-admin@switch > vport-settings-show

 

switch:                      pleiades24

vport-disk-space:            1G

stats-max-memory:            50M

stats-log-enable:            yes

stats-log-interval:          1m

stats-log-disk-space:        50M

system-stats-max-memory:     50M

system-stats-log-enable:     yes

system-stats-log-interval:   1m

system-stats-log-disk-space: 50M

switch:                      pleiades25

vport-disk-space:            500M

stats-max-memory:            50M

stats-log-enable:            yes

stats-log-interval:          1m

stats-log-disk-space:        50M

system-stats-max-memory:     50M

system-stats-log-enable:     yes

system-stats-log-interval:   1m

system-stats-log-disk-space: 50M

 

vport-stats-show

This command is used to display vPort statistics including the number of incoming and outgoing packets.

Syntax   vport-stats-show

time date/time: yyyy-mm-ddThh:mm:ss

Specifies a point in tjme for displaying historical information.

start-time date/time: yyyy-mm-ddThh:mm:ss

Specifies the start time for vPort history collection.

end-time date/time: yyyy-mm-ddThh:mm:ss

Specifies the end time for vPort history collection.

duration duration: #d#h#m#s

Specifies the duration to collect the vPort history.

interval duration: #d#h#m#s

Specifies the intervals to collect vPort history.

since-start

Specifies to display all of the vPort history since collection began on the fabric.

older-than duration: #d#h#m#s

Specifies to display vPort information older than a specific duration.

within-last duration: #d#h#m#s

Specifies to display vPort information with a specific duration.

switch-id node name

Specifies the switch ID for collecting vPort statistics.

hostname hostname-string

Specifies the host name statistics.

ip ip-address

Specifies IP address statistics.

mac mac-address

Specifies the MAC address assigned to the vPort.

vnet vnet name

Specifies VNET statistics.

vlan vlan-id

Specifies VLAN statistics. Range is 0..4095.

vxlan vxlan-id

Specifies VXLAN statistics. Range is 0..16777215.

entity entity-string

Specifies the VM or VM Kernel device name.

vnic-type untagged|tagged|trunked|vm-mgmt|vm-kernel|vMotion|vSAN|FTL|    rep|p-NFC|r-NFC|mgmt|unknown

Specifies the vNic attached to VM traffic type.

 vs-type none|host-vs|distributed-vs|unknow

Specifies the Virtual Switch type

ibytes ibytes-number

Specifies number of incoming bytes.

ipkts ipkts-number

Specifies number of incoming packets.

idiscards idiscards-number

Specifies number of incoming packets discarded.

ierrs ierrs-number

Specifies number of incoming packets with errors..

obytes obytes-number

Specifies number of outoing bytes.

opkts opkts-number

Specifies number of outoing packets.

odiscards odiscards-number

Specifies number of outgoing packets discarded.

oerrs oerrs-number

Specifies number of outgoing packets with errors.

count count-number

Specifies the statistics count.

Defaults   None

Access   CLI

History   .

Version 2.3

Command introduced.

Version 2.4.1

The parameter, count, added.

Version 2.5.4

The parameters, entity, vnic-type, and vs-type added.

Usage   Use this command to display vPort statistics.

Examples  To generate a report, use the following syntax:

CLI network-admin@switch > vport-stats-show