Configuring VXLAN-based Bridge Domains for 802.1Q and QinQ Internetworking


Bridge domains’ configuration process is based upon the deployment of a VXLAN transport as described in the Configuring VXLAN chapter of this guide.


Subsequently, switch ports can be selectively added to a BD to accept either 802.1Q frames or double-tagged 802.1ad frames based on the connected device(s) and/or network(s), as depicted in the Figure 10-6.




Figure 10-6: VXLAN-based BD Internetworking


Switch ports can be connected to either servers/hosts or switches/provider gateways as shown above.


In case of interconnection with an external cloud provider’s gateway devices, as shown on the right hand side of Figure 10-6 the connectivity is based on double-tagged 802.1ad frames, as it is required to preserve all 16M (4094 x 4094) possible combinations of user IDs and service IDs.


On the other hand, connectivity to servers can be based on a single 802.1Q VLAN tag. This case is useful in private cloud networks for direct server-to-server connectivity (for example a Web services node that needs to communicate with a database node).


Alternatively, server NICs can be configured with both an outer VLAN and an inner VLAN ID. In such case, the inner VLAN represents for example the service implemented on such server. Certain network designs employ this double-tagging scheme to be able to scale the number of supported services to 16M. In this case, switch ports have to be configured in 802.1ad mode to preserve the inner tag.


The 802.1Q ports can also be used to connect to customer switches and traffic can be double tagged by the fabric leaf nodes themselves.


Informational note: BD ports can be configured in 802.1Q mode or in 802.1ad/QinQ mode but not in both on the same switch for the same BD. Starting from Netvisor ONE release 6.1.1, in remove-tags mode, this restriction has been lifted (see the following sections for more details).


Before adding ports to any of the aforementioned scenarios, the first basic configuration step is the creation of a VXLAN-based bridge domain entity with the command:


CLI (network-admin@leaf-5) > bridge-domain-create

bridge-domain-create

Create a bridge domain.

name name-string

Specify the name for the bridge domain.

scope local|cluster|fabric

Specify the bridge domain scope.

Specify any of the following options:


vnet vnet-name

Specify the vNET for this bridge domain.

vxlan 0..16777215

Specify the VXLAN identifier for the tunnel.

auto-vxlan|no-auto-vxlan

Specify the options to automatically assign VXLAN and/or assign to VTEPs.

description description-string        

Add a bridge domain description.

rsvd-vlan 1..4093        

Specify the fabric reserved VLAN for cluster switches for bridge domain.

local-rsvd-vlan 1..4093

Specify the local reserved VLAN for cluster switches for bridge domain.

mac-learning|no-mac-learning        

Specify if you want to enable or disable MAC address learning.


CLI (network-admin@leaf-5) > bridge-domain-create name bd1000 scope fabric vxlan 10000 rsvd-vlan 4002


A bridge domain’s scope can be fabric, cluster, or local.


The bridge-domain-create command uses a manually assigned VNI to uniquely identify the bridge domain at the hardware level.

Moreover, with fabric and cluster scope, it must set aside a VLAN ID as reserved for supporting switch clusters:


CLI (network-admin@leaf-5) > bridge-domain-create name bd1000 scope fabric vxlan 10000 rsvd-vlan 4002


This command reserves VLAN 4002 on all cluster switches in the fabric for BD’s internal use, so it can no longer be configured as a regular VLAN number. (The same requirement applies to bridge-domain-create scope cluster commands).


If for a particular pair of cluster switches the reserved VLAN has to be modified, on any one of the two switches you can use the following command:


CLI (network-admin@leaf-5) > bridge-domain-modify name bd1000 local-rsvd-vlan 4006 


Note that the above command requires both cluster switches to be rebooted to take effect. Before rebooting, both VLAN 4002 and 4006 are no longer available but only 4006 is reserved on the cluster switches after reboot.


Also note that in a cluster both switch members are required to use the same mode for a port, either QinQ or 802.1Q, for the same BD.


Bridge domains can also be created with a textual description to provide more context like so:


CLI (network-admin@leaf-5) > bridge-domain-create name bd1000 scope fabric vxlan 10000 description business rsvd-vlan 4002


CLI (network-admin@leaf-5) > bridge-domain-show


name   scope  vxlan auto-vxlan description ports cluster-name

------ ------ ----- ---------- ----------- ---- ------------

bd1000 fabric 10000 no         business    13              


Starting from Netvisor ONE release 6.0.0 the auto-vxlan parameter is supported as an option of the BD creation process.


This new parameter can be used either in combination with an explicit VNI value or implicitly without specifying it. In both cases any created BD or VNI mapping is automatically added to all the existing VTEP connections. Additionally, in the latter case, the VNI value is automatically picked and assigned out of a predefined range (see also the examples below) when scope fabric is used.


The next configuration step is to set up the fabric overlay either with manual tunnel creation or with VTEP object configuration. The latter way is preferred.


In order to manually create a VXLAN tunnel, say, on cluster member leaf-5 in the Figure 10-6, the following commands can be used:


CLI (network-admin@leaf-5) > tunnel-create scope cluster name tunnel-5 vrouter-name vr5 peer-vrouter-name vr1 local-ip 20.20.25.1 remote-ip 20.20.27.1


CLI (network-admin@leaf-5) > trunk-modify name vxlan-loopback-trunk ports 17 jumbo


The same steps are required on the other leaf switches to deploy an overlay comprising a full mesh of VXLAN-based interconnections.


Alternatively, VTEP objects can be configured so that a full mesh of VXLAN interconnections is brought up automatically without requiring manual configuration.


This is the command required to create a VTEP object on a non-clustered switch:


CLI (network-admin@leaf-1) > vtep-create name vtep1 vrouter-name vr1 ip 20.20.25.1


which can be used to create each fabric termination point (vtep1, vtep2, etc. on each leaf switch).


In case of clustered switches using a common VIP, the following command pairs should be used:


CLI (network-admin@leaf-5) > vtep-create name vtep5 vrouter-name vr5 ip 103.103.103.250 virtual-ip 103.103.103.10


CLI (network-admin@leaf-6) > vtep-create name vtep6 vrouter-name vr6 ip 103.103.103.251 virtual-ip 103.103.103.10


The next configuration step is to associate the BD’s VXLAN ID (e.g., 10000) to the newly created tunnel(s) or VTEP objects. For example, this command implements the association with a tunnel: 


CLI (network-admin@leaf-1) > tunnel-vxlan-add name tunnel-1 vxlan 10000


whereas this command implements the association with a VTEP object:


CLI (network-admin@leaf-1) > vtep-vxlan-add name vtep1 vxlan 10000


As mentioned above, starting from Netvisor ONE release 6.0.0, as an alternative to the manual assignment, you can automatically assign a certain user-defined BD or VNI mapping to all tunnels with the following command:


CLI (network-admin@leaf-5) > bridge-domain-create name bd5001234 scope fabric vxlan 5001234 auto-vxlan


Instead, if you want the software to automatically pick and assign the VNI, you can simply enter the following shorter command that requires scope to be fabric:


CLI (network-admin@leaf-5) > bridge-domain-create name BD-VNI-SELF scope fabric auto-vxlan


The range used for automatic VNI assignment can be controlled and modified, if needed, with the vtep-auto-vxlan-show and vtep-auto-vxlan-modify commands.


Once the VXLAN overlay deployment is complete and the BD’s VXLAN ID is (manually or automatically) associated to it, then it is possible to start adding switch ports.


Informational note: Before Netvisor ONE release 6.1.1., when a port is assigned to a BD (as in the examples below) it cannot be associated with a regular VLAN configured with the vlan-create command, and vice versa. The restriction has been lifted in release 6.1.1.


In order to add a port connected to the cloud provider network to the BD, you can use the following command that explicitly maps both inner and outer VLANs to the BD:


CLI (network-admin@leaf-7) > bridge-domain-port-add name bd1000 port 13 outer-vlan 13 inner-vlan 100


This configuration also means that a frame’s MAC lookup in the Layer 2 table is performed including both the outer VLAN and the inner VLAN.


The same configuration can be used to add a port connected to an 802.1ad-configured server to the BD:


CLI (network-admin@leaf-2) > bridge-domain-port-add name bd1000 port 11 outer-vlan 13 inner-vlan 100


In order to add a port connected to an 802.1Q network to the BD, you can use the following command that explicitly maps only the outer VLAN to the BD (and preserves the inner VLAN):


CLI (network-admin@leaf-2) > bridge-domain-port-add name bd1000 port 15 outer-vlan 19


This configuration also means that a frame’s MAC lookup in the Layer 2 table is performed including only the outer VLAN while the inner VLAN is ignored.

       

In order to add a port connected to an 802.1Q server to the BD, you can use the following command that explicitly associates one or more VLANs on the same switch port to the same BD:


CLI (network-admin@leaf-1) > bridge-domain-port-add name bd2100 port 10 vlans 210,310


Note: The multiple VLAN IDs on the same port can be part of the same bridge domain. However, VLAN IDs added to a BD cannot be reused with another BD on the same port. Also note that MAC addresses associated with these two VLAN IDs must be unique within the BD.


Finally, you should also configure all cluster ports/trunks and ports in QinQ mode to work with the 802.1ad TPID (i.e., 0x88A8) with the following command:


CLI (network-admin@switch) > port-config-modify port <port_number> allowed-tpid q-in-q


Port removal from a BD and BD deletion follow the reverse order compared to the addition process described in the above steps.

Ports have to be removed first with the command:


CLI (network-admin@leaf-2) > bridge-domain-port-remove name bd1000 port 15


Then a BD’s VXLAN ID may be manually removed from the associated tunnel(s):


CLI (network-admin@leaf-2) > tunnel-vxlan-remove name tunnel-2 vxlan 10000


or from the corresponding VTEP objects like so:


CLI (network-admin@leaf-2) > vtep-vxlan-remove name vtep2 vxlan 10000


Finally, the BD can be deleted with the following command:


CLI (network-admin@leaf-2) > bridge-domain-delete name bd1000


Starting from Netvisor ONE release 6.0.0, when a BD is deleted, if it was previously created with the auto-vxlan option, the BD or VNI mapping gets removed from all the tunnels automatically, so you don’t need to do it manually.


From Netvisor ONE version 6.1.0, the vxlan-stats-show command displays the statistics for VXLANs associated with bridge domains.


For example, to view the VXLAN statistics for the bridge domain BD100, use the following command:


CLI (network-admin@switch) > vxlan-stats-show bd BD100 layout vertical

time:        03:23:19

vnid:        12591499

vxlan-name:

vnet:

bd:          BD100

ibytes:      7.60T

ibits:       66.8T

ipkts:       3.59G

idrops-pkts: 0

obytes:      7.54T

obits:       66.5T

opkts:       3.59G

odrops-pkts: 0

Configuring Bridge Domains in vNETs


Netvisor ONE version 6.1.0 supports the configuration of bridge domains in vNETs. This enhancement enables vNET users to configure bridge domains on vNET ports so that they can be managed on a per tenant basis.


To configure bridge domains in a vNET, you should first specify the number of allowed bridge domains in the vNET when creating it. Also, you must specify the vlan-type as private, because the default vlan-type is public but bridge domains are supported only in global or private vNETs. For example:


CLI (network-admin@switch) vnet-create name vnet1 scope fabric vlan-type private vlans 300-400 num-bridge-domains 3 vxlans 10100 vxlan-end 10200


You can now create a bridge domain in vnet1 by using the command:


CLI (network-admin@switch) bridge-domain-create name bd1 scope fabric vxlan 10100 vnet vnet1


View the bridge domain configuration by using the command:


CLI (network-admin@switch) > bridge-domain-show layout vertical

name:               bd1

vnet:               vnet1

scope:              fabric

vxlan:              10100

auto-vxlan:         no

rsvd-vlan:          2833

vxlan-inner-packet: auto

qinq_rsvd_vlan:     2833

mac-learning:       on


Note:You cannot specify a reserved VLAN for a bridge domain in a vNET configuration as the reserved VLAN is automatically selected from the vtep-auto-vlan range. Since this VLAN range is common to all vNETs, you cannot create bridge domains in a vNET if this pool is exhausted. 


The vtep-auto-vlan range has 500 VLANs allocated by default:


CLI (network-admin@switch) > vtep-auto-vlan-show

vlans:    2500-2999


You can widen this range, for example, by 11 VLANs by using the command:


CLI (network-admin@switch) > vtep-auto-vlan-modify vlans 2500 vlan-end 3010


vtep-auto-vlan-modify

Modify the VLAN ID range for automatic assignment to VTEPs at the fabric level.

vlans 0..4095

Specify the starting VLAN ID for vtep-auto-vlan range.

vlan-end 0..4095

Specify the ending  VLAN ID for vtep-auto-vlan range.


Note: The vtep-auto-vlan reserved range and the VLAN range manually allocated to each vNET must be mutually exclusive.


Add ports to bd1 by using the bridge-domain-port-add command:


CLI (network-admin@switch) > bridge-domain-port-add name bd1 port 33 vlans 100


Note: You can only add vNET managed ports to the bridge domain. However, there is no restriction on assigning VLANs that are not part of the vNET to the bridge domain.


View the configuration using the command:


CLI (network-admin@switch) > bridge-domain-port-show

switch name port vlans   l2-learning

------ ---- ---- ------- -----------

switch bd1  33   100     none


To complete the configuration, as demonstrated earlier, associate the bridge domain's VXLAN ID with a tunnel by using the command:


CLI (network-admin@switch) > tunnel-vxlan-add name t1 vxlan 10100


You can also associate the bridge domain's VXLAN ID with a VTEP by using the vtep-vxlan-add command as shown earlier.


north