If you want to connect the two cluster nodes to an upstream switch or to a downstream host in a redundant fashion, you can configure a vLAG between the uplinks or the downlinks on the cluster nodes.


For example, if switch1 has port 53 connected to an upstream switch and switch2 has port 19 connected to the same upstream switch, create a vLAG by executing the vlag-create command on either of the cluster switches (switch1 in this example):


CLI (network-admin@switch) > vlag-create name uplink port 53 [peer-switch switch2] peer-port 19


To verify the configuration, use the following command:


CLI (network-admin@switch) > vlag-show


name        cluster        mode                switch         port         peer-switch         peer-port status        local-state        lacp-mode

----        -------        ----                ------         ----         -----------         --------- ------        -----------        ---------

uplink        cluster1        active-acti        switch1 53         switch2         19          normal        enabled        active


Note: Before you can create a vLAG, you must configure the two switches in a cluster.