Alert Log Messages


Version 6.1.1-6010118491


Identifier

Message

Code

Description

Severity

nvOSd_start 

nvOSd start: version=version(s) changeset=changeset(s) branch=branch(s)

11008

nvOSd startup

Note

syscall_failed_Critical

feature(s): syscall(s) failed: error

11012

A system call failed.

Critical

restart_nvOSd_failed

Failed to restart exe(s): error-mgs

11014

Failed to restart nvOSd

Critical

nvOSd_init_failed

nvOSd failed to start: feature(s): error-mgs

11015

nvOSd was unable to start.

Critical

loop_detected  

LOOP: mac(s) vlan(s) was on port_type(s) old_port-id ((ip(s)), now new_port-id) ((new_ip(s))

11016

Detected an L2 loop.

Note

simulator_mode

Failed to init switch hardware.

11018

Simulator mode entered but not from command line.

Critical

stp_switch_enable_failed

STP failed to initialize for switch hardware.

11028

STP initialization for underlying hardware switch failed.

Critical

stp_default_spanning_tree_failed

STP Failed to Create Default Spanning Tree: vlan= vlan-id

11029

Unable to create the Spanning Tree for default VLAN.

Critical

stp_flow

STP Failed to install flow(s) fpr BPDU reception: flow(s)

11030

Unable to install STP flow(s) for the reception of STP packets.

Critical

stp_worker_thread_failed

STP failed to create worker thread: vlan=vlan-id

11031

STP was unable to create worker thread for Spanning Tree.

Critical

stp_switch_port_state

STP Port Failure: port=port vlan=vlan-id trunk=trunk-id

11045

Unable to set the port state for the port on the VLAN.

Critical

igmp_switch_init

IGMP snooping unable to initialize switch hardware for groups.

11047

igmp was unable to initialize switch hardware for the group.

Critical

ps_status_change  

Power supply state change

11304

The status of the power supplies changed.

Warn

fan_status_change   

Fan status change

11305

The status of the fans changed.

Warn

xact_node_ignored   

Ignoring offline cluster node name=%[name]s for transaction tid=%[tid]d

11366

ignored offline cluster node for transaction.

Warn

xact_recover   

Transactions out-of-sync detected, rolled forward from old=%[old]d to new=%[new]d via node=%[node]s

11367

auto-recovered from transactions being out of sync.

Warn

xact_recover_failed   

Transaction auto-recover failed: %[msg]s

11368

auto-recover attempted but failed

Warn

host_port_loop_detected  

Looping traffic detected on host-port=%[port]d vlan=%[vlan]d. Traffic on this port/VLAN will be ignored until loop resolved

11380

loop detected on host port

Warn

host_port_loop_resolved  

Traffic has stopped looping on host-port=%[port]d vlan=%[vlan]d

11381

loop on host port is no longer happening

Note

congestion_on_port

Congestion detected on port=%[port]d

11401

Congestion detected on port. Positive icongdrop/ocongdrop

Critical

congestion_relieved_on_port

Congestion relieved on port=%[port]d

11402

Congestion relieved on port.

Critical

bad_xcvr_detected  

unable to access I2C bus; possible bad transceiver

11409

unable to access I2C bus; possibly a bad transceiver is inserted

Error

tacacs_server_ok   

server=%[server]s TACACS+ authorization enabled due to server errors resolved

11415

TACACS+ server has recovered from errors. TACACS+ Authorization enabled.

Note

ntp_server_sync

NTP server is unresolvable/unreachable

11431

NTP server not resolvable/reachable

Critical

nxu_module_fw_upgrade  

Installed version: %[inst]s; available version %[avail]s

11434

One or more Lutera xcvrs require module firmware upgrade

Warn

nxu_chipset_fw_upgrade  

Installed version: %[inst]s; available version %[avail]s

11435

One or more Lutera xcvrs require chipset firmware upgrade

Warn

disk_health_below_RMA

The disk health level %[current]d is significantly below recommended level %[rma]d, please notify Pluribus TAC immediately

11514

The disk health is below the minimum required to work needs to be RMAed


Critical

disk_health_below_minimum

The disk health level %[current]d is below recommended level %[rma]d, please notify Pluribus TAC

11515

The disk health is below the minimum required to work

Critical

disk_health_filesystem_readonly

The filesystem %[part]s is in Read Only mode, please notify Pluribus TAC immediately

11516

The disk partition is mounted read-only

Critical

syslog_tls_server_down   

tcp-tls connection to syslog server=%[server]s down. Logs are not getting exported

20006

Connection to syslog export tcp/tls server is down. syslog export to external server is not happening.

Error

syslog_tls_server_restored  

tcp-tls connection to syslog server=%[server]s restored. Log export is operational

20007

Connection to syslog export tcp/tls server is restored.

Note

syslog_tls_server_dropped   

syslog export log messages to syslog server=%[server]s getting dropped

20008

Syslog export message(s) to tcp/tls server dropped.

Error

mon_failure_detected 

Monitor detected failure failure(s)

30006

Monitor detected a failure.

Warn

mon_cpu_usage_high  

High cpu usage detected.

30010

High CPU usage detected.

Note

mon_memory_usage_high  

High memory usage detected

30011

high memory usage detected.

Note

mon_disable_ports  

nvOSd cannot be revived; disabling ports to prevent headless switching.

30012

Monitor failed to restart nvOSd; disabling ports to prevent headless switching.

Critical

mon_keepalive_hung

nvOS_mon is possibly stuck ! %[action]s

30014

nvOS_mon keepalive_checker thread is possibly hung.

Critical

mon_autoreboot_cancel

%[reason]s; the system will not be rebooted.

30015

System will not be rebooted; auto-reboot is disabled or software-upgrade is in progress.

Critical

mon_autoreboot_failed

System failed to auto-reboot: %[reason]s

30016

System failed to auto-reboot: %[reason]s

Critical

mon_cpu_usage_higher_than_seventy

CPU usage higher than 70 percent detected

30017

CPU usage higher than 70 percent detected

Critical

fanmon_fan_missing  

Controller controller-id fan fan-id is missing

31001

There is no fan in the fan slot

Warn

fanmon_fan_fault  

Controller controller-id fan fan-id fault:fault(s)

31003

There is a problem with the fan.

Warn

fanmon_fan_fault_compensate  

One fan fault is detected so setting all other fans to max speed to compensate.

31004

One fan is faulty on the system.

Warn

fanmon_poweroff  

Fan monitor powering down system due to faults or over temp.

31005

Fans are not working properly on the server-switch.

Critical

smf_nvOSd_start   

smf starting nvOS

31007

nvOS starting

Note

smf_nvOSd_stop    

smf stopping nvOS

31008

nvOS stopping.

Note

hwmon_start   

=== nvOSd_hwmon start ===

32000

nvOSd_hwmon startup

Note

hwmon_exit  

exiting because %[reason]s

32001

hardware monitor exiting for some reason

Warn

hwmon_power_supply_ok  

power supply %[name]s has recovered from faulted state

32003

power supply OK

Note

hwmon_fan_fault

fan %[name]s fault

32004

fan has failed

Critical

hwmon_fan_ok   

fan %[name]s has recovered from faulted state

32005

fan ok

Note

hwmon_sensor_fault  

temperature sensor %[name]s fault

32006

temperature sensor fault

Warn

hwmon_sensor_ok  

temperature sensor %[name]s has recovered from faulted state

32007

temperature sensor ok

Note

hwmon_temp_Critical

%[name]s at %[t1]dC, shutdown at %[t2]dC

32009

high temperature Critical

Critical

hwmon_temp_shutdown

shutting down system: %[name]s at %[t1]dC

32010

high temperature system shutdown

Critical

hwmon_shutdown_failed

system high temperature shutdown failed

32011

high temperature system shutdown failed

Critical

hwmon_temp_ok   

%[name]s at %[t1]dC, temperature ok

32012

temperature OK

Note



Identifier

Message

Code

Description

Type

vNET

Severity

port_down  

Down

11003

A port is down.

Port

by-port

Note

stp_mst_port_state 

STP Port State Change: port=%[port]d instance=%[instance]d: %[old_state]s -> %[state]s

11383

port changed stp state

Port


Info

certificate_expiring  

%[cert]s certificate expiring in %[days]d days

11511

Show how many days left for certificate expiry

Port


Note

certificate_expired  

%[cert]s certificate expired

11512

Display the expired certificate

System


Warn

stp_port_state  

port changed stp state

11026

The port changed the STP state

Port


Info

north
    keyboard_arrow_up
    keyboard_arrow_down
    description
    print
    feedback
    support
    business
    rss_feed
    south