Alert Log Messages
Version 6.1.1-6010118491
Identifier |
Message |
Code |
Description |
Severity |
nvOSd_start |
nvOSd start: version=version(s) changeset=changeset(s) branch=branch(s) |
11008 |
nvOSd startup |
Note |
syscall_failed_Critical |
feature(s): syscall(s) failed: error |
11012 |
A system call failed. |
Critical |
restart_nvOSd_failed |
Failed to restart exe(s): error-mgs |
11014 |
Failed to restart nvOSd |
Critical |
nvOSd_init_failed |
nvOSd failed to start: feature(s): error-mgs |
11015 |
nvOSd was unable to start. |
Critical |
loop_detected |
LOOP: mac(s) vlan(s) was on port_type(s) old_port-id ((ip(s)), now new_port-id) ((new_ip(s)) |
11016 |
Detected an L2 loop. |
Note |
simulator_mode |
Failed to init switch hardware. |
11018 |
Simulator mode entered but not from command line. |
Critical |
stp_switch_enable_failed |
STP failed to initialize for switch hardware. |
11028 |
STP initialization for underlying hardware switch failed. |
Critical |
stp_default_spanning_tree_failed |
STP Failed to Create Default Spanning Tree: vlan= vlan-id |
11029 |
Unable to create the Spanning Tree for default VLAN. |
Critical |
stp_flow |
STP Failed to install flow(s) fpr BPDU reception: flow(s) |
11030 |
Unable to install STP flow(s) for the reception of STP packets. |
Critical |
stp_worker_thread_failed |
STP failed to create worker thread: vlan=vlan-id |
11031 |
STP was unable to create worker thread for Spanning Tree. |
Critical |
stp_switch_port_state |
STP Port Failure: port=port vlan=vlan-id trunk=trunk-id |
11045 |
Unable to set the port state for the port on the VLAN. |
Critical |
igmp_switch_init |
IGMP snooping unable to initialize switch hardware for groups. |
11047 |
igmp was unable to initialize switch hardware for the group. |
Critical |
ps_status_change |
Power supply state change |
11304 |
The status of the power supplies changed. |
Warn |
fan_status_change |
Fan status change |
11305 |
The status of the fans changed. |
Warn |
xact_node_ignored |
Ignoring offline cluster node name=%[name]s for transaction tid=%[tid]d |
11366 |
ignored offline cluster node for transaction. |
Warn |
xact_recover |
Transactions out-of-sync detected, rolled forward from old=%[old]d to new=%[new]d via node=%[node]s |
11367 |
auto-recovered from transactions being out of sync. |
Warn |
xact_recover_failed |
Transaction auto-recover failed: %[msg]s |
11368 |
auto-recover attempted but failed |
Warn |
host_port_loop_detected |
Looping traffic detected on host-port=%[port]d vlan=%[vlan]d. Traffic on this port/VLAN will be ignored until loop resolved |
11380 |
loop detected on host port |
Warn |
host_port_loop_resolved |
Traffic has stopped looping on host-port=%[port]d vlan=%[vlan]d |
11381 |
loop on host port is no longer happening |
Note |
congestion_on_port |
Congestion detected on port=%[port]d |
11401 |
Congestion detected on port. Positive icongdrop/ocongdrop |
Critical |
congestion_relieved_on_port |
Congestion relieved on port=%[port]d |
11402 |
Congestion relieved on port. |
Critical |
bad_xcvr_detected |
unable to access I2C bus; possible bad transceiver |
11409 |
unable to access I2C bus; possibly a bad transceiver is inserted |
Error |
tacacs_server_ok |
server=%[server]s TACACS+ authorization enabled due to server errors resolved |
11415 |
TACACS+ server has recovered from errors. TACACS+ Authorization enabled. |
Note |
ntp_server_sync |
NTP server is unresolvable/unreachable |
11431 |
NTP server not resolvable/reachable |
Critical |
nxu_module_fw_upgrade |
Installed version: %[inst]s; available version %[avail]s |
11434 |
One or more Lutera xcvrs require module firmware upgrade |
Warn |
nxu_chipset_fw_upgrade |
Installed version: %[inst]s; available version %[avail]s |
11435 |
One or more Lutera xcvrs require chipset firmware upgrade |
Warn |
disk_health_below_RMA |
The disk health level %[current]d is significantly below recommended level %[rma]d, please notify Pluribus TAC immediately |
11514 |
The disk health is below the minimum required to work needs to be RMAed |
Critical |
disk_health_below_minimum |
The disk health level %[current]d is below recommended level %[rma]d, please notify Pluribus TAC |
11515 |
The disk health is below the minimum required to work |
Critical |
disk_health_filesystem_readonly |
The filesystem %[part]s is in Read Only mode, please notify Pluribus TAC immediately |
11516 |
The disk partition is mounted read-only |
Critical |
syslog_tls_server_down |
tcp-tls connection to syslog server=%[server]s down. Logs are not getting exported |
20006 |
Connection to syslog export tcp/tls server is down. syslog export to external server is not happening. |
Error |
syslog_tls_server_restored |
tcp-tls connection to syslog server=%[server]s restored. Log export is operational |
20007 |
Connection to syslog export tcp/tls server is restored. |
Note |
syslog_tls_server_dropped |
syslog export log messages to syslog server=%[server]s getting dropped |
20008 |
Syslog export message(s) to tcp/tls server dropped. |
Error |
mon_failure_detected |
Monitor detected failure failure(s) |
30006 |
Monitor detected a failure. |
Warn |
mon_cpu_usage_high |
High cpu usage detected. |
30010 |
High CPU usage detected. |
Note |
mon_memory_usage_high |
High memory usage detected |
30011 |
high memory usage detected. |
Note |
mon_disable_ports |
nvOSd cannot be revived; disabling ports to prevent headless switching. |
30012 |
Monitor failed to restart nvOSd; disabling ports to prevent headless switching. |
Critical |
mon_keepalive_hung |
nvOS_mon is possibly stuck ! %[action]s |
30014 |
nvOS_mon keepalive_checker thread is possibly hung. |
Critical |
mon_autoreboot_cancel |
%[reason]s; the system will not be rebooted. |
30015 |
System will not be rebooted; auto-reboot is disabled or software-upgrade is in progress. |
Critical |
mon_autoreboot_failed |
System failed to auto-reboot: %[reason]s |
30016 |
System failed to auto-reboot: %[reason]s |
Critical |
mon_cpu_usage_higher_than_seventy |
CPU usage higher than 70 percent detected |
30017 |
CPU usage higher than 70 percent detected |
Critical |
fanmon_fan_missing |
Controller controller-id fan fan-id is missing |
31001 |
There is no fan in the fan slot |
Warn |
fanmon_fan_fault |
Controller controller-id fan fan-id fault:fault(s) |
31003 |
There is a problem with the fan. |
Warn |
fanmon_fan_fault_compensate |
One fan fault is detected so setting all other fans to max speed to compensate. |
31004 |
One fan is faulty on the system. |
Warn |
fanmon_poweroff |
Fan monitor powering down system due to faults or over temp. |
31005 |
Fans are not working properly on the server-switch. |
Critical |
smf_nvOSd_start |
smf starting nvOS |
31007 |
nvOS starting |
Note |
smf_nvOSd_stop |
smf stopping nvOS |
31008 |
nvOS stopping. |
Note |
hwmon_start |
=== nvOSd_hwmon start === |
32000 |
nvOSd_hwmon startup |
Note |
hwmon_exit |
exiting because %[reason]s |
32001 |
hardware monitor exiting for some reason |
Warn |
hwmon_power_supply_ok |
power supply %[name]s has recovered from faulted state |
32003 |
power supply OK |
Note |
hwmon_fan_fault |
fan %[name]s fault |
32004 |
fan has failed |
Critical |
hwmon_fan_ok |
fan %[name]s has recovered from faulted state |
32005 |
fan ok |
Note |
hwmon_sensor_fault |
temperature sensor %[name]s fault |
32006 |
temperature sensor fault |
Warn |
hwmon_sensor_ok |
temperature sensor %[name]s has recovered from faulted state |
32007 |
temperature sensor ok |
Note |
hwmon_temp_Critical |
%[name]s at %[t1]dC, shutdown at %[t2]dC |
32009 |
high temperature Critical |
Critical |
hwmon_temp_shutdown |
shutting down system: %[name]s at %[t1]dC |
32010 |
high temperature system shutdown |
Critical |
hwmon_shutdown_failed |
system high temperature shutdown failed |
32011 |
high temperature system shutdown failed |
Critical |
hwmon_temp_ok |
%[name]s at %[t1]dC, temperature ok |
32012 |
temperature OK |
Note |
Identifier |
Message |
Code |
Description |
Type |
vNET |
Severity |
port_down |
Down |
11003 |
A port is down. |
Port |
by-port |
Note |
stp_mst_port_state |
STP Port State Change: port=%[port]d instance=%[instance]d: %[old_state]s -> %[state]s |
11383 |
port changed stp state |
Port |
|
Info |
certificate_expiring |
%[cert]s certificate expiring in %[days]d days |
11511 |
Show how many days left for certificate expiry |
Port |
|
Note |
certificate_expired |
%[cert]s certificate expired |
11512 |
Display the expired certificate |
System |
|
Warn |
stp_port_state |
port changed stp state |
11026 |
The port changed the STP state |
Port |
|
Info |