System Log Messages
Version 6.1.1-6010118491
Identifier |
Message |
Code |
Description |
Severity |
system_drop |
Lost drops-id msgs |
10002 |
Unable to deliver system log(s) to nvlogd so system logs dropped. |
Warn |
update_find_server_failed |
Failed to contact update server. |
11006 |
Failed to find update server. |
Warn |
update_wrong_redirect |
Unexpected redirect url(s) from update server. |
11007 |
Got an unexpected redirect from HTTP update server lookup. |
Warn |
nvOSd_start |
nvOSd start: version=version(s) changeset=changeset(s) branch=branch(s) |
11008 |
nvOSd startup |
Note |
pkt_alloc_failed |
feature(s) failed to allocate a send buffer. |
11009 |
Failed to allocate a packet for sending from the CPU |
Warn |
syscall_failed_Critical |
feature(s): syscall(s) failed: error |
11012 |
A system call failed. |
Critical |
resstart_nvOSd |
Restarting exe(s) |
11013 |
Restarting nvOSd. |
Note |
restart_nvOSd_failed |
Failed to restart exe(s): error-mgs |
11014 |
Failed to restart nvOSd |
Critical |
nvOSd_init_failed |
nvOSd failed to start: feature(s): error-mgs |
11015 |
nvOSd was unable to start. |
Critical |
loop_detected |
LOOP: mac(s) vlan(s) was on port_type(s) old_port-id ((ip(s)), now new_port-id) ((new_ip(s)) |
11016 |
Detected an L2 loop. |
Note |
mac_moved |
MOVING MAC mac(s), from old_port_type(s) old_port-id (old_ip(s)) new_port_type(s) new_port-id (new_ip(s)) |
11017 |
MAC moved from one port to another. |
Note |
simulator_mode |
Failed to init switch hardware. |
11018 |
Simulator mode entered but not from command line. |
Critical |
fabric_joined |
Joined fabric fabname(s). |
11019 |
Switch joined a fabric. |
Note |
fabric_unjoined |
Unjoined fabric fabname(s) |
11020 |
Switch un-joined a fabric. |
Note |
config_imported |
Imported configuration from file(s). |
11021 |
Imported a new configuration. |
Note |
stp_switch_enable_failed |
STP failed to initialize for switch hardware. |
11028 |
STP initialization for underlying hardware switch failed. |
Critical |
stp_default_spanning_tree_failed |
STP Failed to Create Default Spanning Tree: vlan= vlan-id |
11029 |
Unable to create the Spanning Tree for default VLAN. |
Critical |
stp_flow |
STP Failed to install flow(s) fpr BPDU reception: flow(s) |
11030 |
Unable to install STP flow(s) for the reception of STP packets. |
Critical |
stp_worker_thread_failed |
STP failed to create worker thread: vlan=vlan-id |
11031 |
STP was unable to create worker thread for Spanning Tree. |
Critical |
stp_config_failed |
Loading and application STP configuration failed. |
11041 |
The loading and application of STP configuration failed. |
Warn |
stp_switch_port_state |
STP Port Failure: port=port vlan=vlan-id trunk=trunk-id |
11045 |
Unable to set the port state for the port on the VLAN. |
Critical |
stp_trunk_port_state |
STP Set Port State: port vlan trunk |
11046 |
Invalid trunk in use by the spanning tree |
Warn |
igmp_switch_init |
IGMP snooping unable to initialize switch hardware for groups. |
11047 |
igmp was unable to initialize switch hardware for the group. |
Critical |
igmp_flow_add |
IGMP snooping unable to add flow flow(s). |
11048 |
igmp was unable to add a flow for IGMP packet processing. |
Warn |
igmp_flow_remove |
IGMP snooping not able to remove flow flow(s). |
11049 |
IGMP snooping unable to remove flow for IGMP processing. |
Warn |
igmp_query_start |
IGMP snooping unable to start query state machine. |
11050 |
IGMP snooping unable to start query state machine. |
Warn |
igmp_query_stop |
IGMP snooping unable to stop query state machine. |
11051 |
IGMP snooping unable to stop query state machine. |
Warn |
igmp_switch_fini |
IGMP snooping unable to halt switch hardware for groups. |
11052 |
IGMP snooping unable to halt switch hardware for groups. |
Warn |
igmp_static_load |
IGMP snooping unable to load static IGMP group. |
11053 |
IGMP snooping unable to load static IGMP group. |
Warn |
igmp_static_source_load |
IGMP snooping unable to load static IGMP source list. |
11054 |
IGMP snooping unable to load static IGMP source list. |
Warn |
igmp_flooding |
IGMP flooding not enabled. |
11055 |
IGMP flooding not enabled. |
Warn |
igmp_group_add_failed |
IGMP Group Add Failed: vlan-id group(s) |
11071 |
IGMP snooping failed to add a group to switch hardware. |
Warn |
igmp_group_remove_failed |
IGMP Group Remove Failed: vlan-id group(s) |
11072 |
IGMP snooping failed to remove a group from switch hardware. |
Warn |
software_upgrade_initiated |
nvOS software upgrade initiated for version(s). |
11073 |
Software upgrade initiated; downloading and installing new packages. |
Note |
software_upgrade_complete |
System and nvOS software upgrade complete version(s). |
11074 |
System and nvOS software upgrade complete. |
Note |
software_upgrade_failed |
nvOS software upgrade failed. |
11075 |
nvOS software upgrade failed. |
Warn |
system_reboot |
System reboot initiated by nvOS. |
11076 |
System reboot initiated by nvOS. |
Note |
system_reboot_failed |
System reboot initiated by nvOSd failed. |
11077 |
System reboot initiated by nvOSd failed. |
Warn |
lldp_agent_create_thread_failed |
LLDP Agent Thread Create Failed: mac(s) group(s) error |
11079 |
Creation of threads for LLDP Agent failed. |
Warn |
lldp_flow_add_failed |
LLDP Flow Add Failed: flow(s) |
11080 |
Adding flow for LLDP packet reception failed. |
Warn |
lldp_flow_remove_failed |
LLDP Flow Remove Failed: flow(s) |
11081 |
Removing flow for LLDP packet reception failed. |
Warn |
evb_platform_not_supported |
EVB is not supported on this platform: port |
11089 |
EVB is not supported on this platform. |
Warn |
evb_ecp_not_enabled |
EVB ECP is Not Enabled: port |
11090 |
Received EVB TLV with ECP is not enabled. |
Warn |
evb_flow_remove_failed |
EVB Flow Remove Failed: flowstr(s) |
11095 |
Unable to remove specified EVB flow. |
Warn |
lldp_agent_create_failure |
LLDP Agent Create Failed: agent(s) |
11111 |
Failed to create LLDP agent for one of three agent addresses. |
Warn |
stats_log_open_failed |
Log file open failed. |
11140 |
The log file failed to open. |
Warn |
container_rebuild_start |
container=%[container]s rebuild is started |
11141 |
container rebuild is started |
Warn |
container_rebuild_end |
container=%[container]s rebuild is completed |
11142 |
container rebuild is completed |
Warn |
all_container_rebuild |
all containers are rebuilt |
11143 |
all containers are rebuilt |
Warn |
loop_broken |
A loop was broken on port/vlan for mac/ip |
11180 |
A loop was broken on a port or VLAN for a MAC or IP address |
Warn |
loop_stp |
A loop was detected that STP should have prevented. |
11181 |
STP did not prevent a loop on the network. |
Warn |
update_auto_upgrade |
Update server initiated upgrade |
11210 |
The update server initiated an upgrade for nvOS. |
Note |
update_error |
Update server sent an error message |
11211 |
The update server sent an error message. |
Warn |
ps_initial_status |
Power supply initial status. |
11302 |
The initial status of the power supplies. |
Warn |
fan_initial_status |
Fan initial status |
11303 |
The initial status of the fans. |
Warn |
ps_status_change |
Power supply state change |
11304 |
The status of the power supplies changed. |
Warn |
fan_status_change |
Fan status change |
11305 |
The status of the fans changed. |
Warn |
fabric_node_duplicate_ip |
Fabric node has the same ip=%[ip]I as the local node, cannot send to it |
11319 |
Fabric node has the same IP as the local node, cannot send to it. |
Warn |
upgrade_error |
software upgrade error: %[name]s: %[func]s - %[err]s |
11324 |
Software Upgrade errors |
Warn |
upgrade_informational |
software upgrade Note: %[name]s: %[func]s - %[info]s |
11325 |
Software Upgrade informational messages |
Note |
upgrade_reboot |
System reboot initiated by upgrade agent |
11326 |
System reboot initiated by software upgrade |
Note |
upgrade_reboot_failed |
System reboot initiated by upgrade agent failed |
11327 |
System reboot initiated by software upgrade failed |
Warn |
openstack_nat_failed |
Failed to setup NAT on the OpenStack controller %[name]s |
11328 |
Failed to configure NAT for OpenStack |
Warn |
mac_tunnel_to_port |
MOVING MAC=%[mac]M, vlan=%[vlan]d from tunnel=%[tunnel]s ip=%[old_ip]I to port=%[port]d ip=%[new_ip]I %[caller]s |
11329 |
MAC moved from a tunnel to a port |
Warn |
mac_port_to_switch |
MOVING MAC=%[mac]M, vlan=%[vlan]d from switch=%[old_sw]s port=%[old_port]d ip=%[old_ip]I to switch=%[new_sw]s port=%[new_port]d ip=%[new_ip]I %[caller]s |
11330 |
MAC moved from a port to another switch |
Note |
mld_flow_add |
mld snooping unable to add flow: flow=%[flow]s |
11341 |
MLD was unable to add a flow for MLD packet processing |
Warn |
mld_flow_remove |
mld snooping not able to remove flow: flow=%[flow]s |
11342 |
MLD snooping unable to remove flow for MLD processing |
Warn |
mld_query_start |
mld snooping unable to start query state machine |
11343 |
MLD snooping unable to start query state machine. |
Warn |
mld_query_stop |
mld snooping unable to stop query state machine |
11344 |
MLD was not able to stop the query state machine. |
Warn |
mld_static_load |
mld snooping unable to load static mld group |
11345 |
MLD snooping unable to load static MLD group. |
Warn |
mld_static_source_load |
mld snooping unable to load static mld group source list |
11346 |
MLD snooping unable to load static mld group source list. |
Warn |
xact_node_ignored |
Ignoring offline cluster node name=%[name]s for transaction tid=%[tid]d |
11366 |
ignored offline cluster node for transaction. |
Warn |
xact_recover |
Transactions out-of-sync detected, rolled forward from old=%[old]d to new=%[new]d via node=%[node]s |
11367 |
auto-recovered from transactions being out of sync. |
Warn |
xact_recover_failed |
Transaction auto-recover failed: %[msg]s |
11368 |
auto-recover attempted but failed |
Warn |
ip_moved |
Moving ip=%[ip]I from old-mac=%[old_mac]M to new-mac=%[new_mac]M |
11369 |
IP address moved from one MAC to another MAC |
Note |
software_license_expiring |
software license(s) expiring soon code=%[code]s expires_on=%[expires_on]s |
11370 |
software license(s) expiring |
Warn |
software_license_expired |
software license(s) have expired code=%[code]s expired_on=%[expires_on]s |
11371 |
software license(s) have expired |
Warn |
l2_check_missing |
Add missing l2 entry to hardware: mac=%[mac]s vlan=%[vlan]d vxlan=%[vxlan]d port=%[port]d result=%[result]s |
11376 |
Add layer 2 entry that was missing in hardware |
Warn |
l2_check_bad_port |
Fix l2 entry in hardware with incorrect port: mac=%[mac]s vlan=%[vlan]d vxlan=%[vxlan]d old_port=%[old_port]d new_port=%[new_port]d result=%[result]s |
11377 |
Fix layer 2 entry in hardware with incorrect port |
Warn |
l2_check_orphaned |
Remove orphaned l2 entry from hardware: mac=%[mac]s vlan=%[vlan]d vxlan=%[vxlan]d port=%[port]d result=%[result]s |
11378 |
Remove orphaned layer 2 entry in hardware (not in software table) |
Warn |
mac_move_denied |
MOVE DENIED mac=%[mac]M vlan=%[vlan]d vxlan=%[vxlan]d from switch=%[sw]n port=%[port]d to deny-switch=%[deny_sw]n deny-port=%[deny_port]d reason=%[reason]s |
11379 |
Mac moved not allowed |
Note |
host_port_loop_detected |
Looping traffic detected on host-port=%[port]d vlan=%[vlan]d. Traffic on this port/VLAN will be ignored until loop resolved |
11380 |
loop detected on host port |
Warn |
host_port_loop_resolved |
Traffic has stopped looping on host-port=%[port]d vlan=%[vlan]d |
11381 |
loop on host port is no longer happening |
Note |
owner_mac_moved |
caller=%[caller]s owner=%[owner]n mac=%[mac]M vlan=%[vlan]d moved from old-local-port=%[old_port]d to new-local-port=%[new_port]d |
11382 |
other switch's mac moved from one local port to another |
Note |
mstp_set_port_state_failed |
STP Port State Failure: port=%[port]d instance=%[instance]d |
11384 |
Unable to set the stp state for the port on the MST instance |
Critical |
mac_port_to_tunnel |
MOVING MAC=%[mac]M, vnet=%[vnet]s vlan=%[vlan]d from port=%[port]d ip=%[old_ip]I to tunnel=%[tunnel]s ip=%[new_ip]I %[caller]s |
11385 |
mac moved from a port to a tunnel |
Note |
cluster_vlag_l2_update_failed |
Updating mac=%[mac]M vnet=%[vnet]s vlan=%[vlan]d from peer update to vlag port port=%[port]d failed, cluster may be out-of-sync: reason=%[reason] |
11386 |
updating mac to vlag port in response to peer status update failed, cluster L2 may be out of sync |
Warn |
cluster_tunnel_l2_update_failed |
Updating mac=%[mac]M vxlan=%[vxlan]d tunnel=%[tunnel]s from peer update failed, cluster may be out-of-sync: reason=%[reason]s |
11387 |
updating tunnel mac in response to peer status update failed, cluster L2 may be out of sync |
Warn |
cluster_comm_l2_update_failed |
Updating mac=%[mac]M vnet=%[vnet]s vlan=%[vlan]d from peer update to cluster port port=%[port]d failed, cluster may be out-of-sync: reason=%[reason]s |
11388 |
updating mac to cluster link in response to peer status update failed, cluster L2 may be out of sync |
Warn |
l2_check_bad_tunnel |
Fix l2 entry in hardware with incorrect tunnel: mac=%[mac]s vnet=%[vnet]s vlan=%[vlan]d vxlan=%[vxlan]d old_tunnel=%[old_tunnel]s new_tunnel=%[new_tunnel]s result=%[result]s |
11389 |
Fix layer 2 entry in hardware with incorrect tunnel |
Note |
l2_check_mismatch_vport |
Mismatched vport entry: mac=%[mac]s vlan=%[vlan]d vxlan=%[vxlan]d hw_vlan=%[hw_vlan]d hw_vxlan=%[hw_vxlan]d result=%[result]s |
11390 |
Mismatched vport entry |
Note |
l2_check_mark_port_mac |
Marked vport as port-mac: mac=%[mac]s vlan=%[vlan]d vxlan=%[vxlan]d |
11391 |
Marked owned local vport as port-mac |
Warn |
l2_check_delete_port_mac |
Delete invalid port-mac vport: mac=%[mac]s vlan=%[vlan]d vxlan=%[vxlan]d |
11392 |
Delete port-mac that should not be in vport table |
Warn |
hostid_collision_detected |
Our hostid is being used by another node %[node_name]s |
11393 |
received keep-alive from another node having same hostid |
Critical |
mirror_to_cpu_configured |
Mirror to CPU configured on vFlow %[vflow_name]s |
11395 |
Mirror to CPU configured |
Note |
low_disk_space |
Disk Space Usage has exceeded threshold of 70 percent |
11396 |
Disk space usage exceeds 70 percent |
Warn |
stp_vnet_port_recv |
received STP BPDU on vnet port: port=%[port]d |
11397 |
received an STP BPDU on a vnet port |
Warn |
igmp_disabled |
Disabling IGMP on vlan: vlan=%[vlan]d |
11398 |
Disabling IGMP on vlan |
Note |
igmp_enabled |
Enabling IGMP on vlan: vlan=%[vlan]d |
11399 |
Enabling IGMP on vlan |
Note |
l2_check_hw_invalid |
Remove invalid l2 entry from hardware: mac=%[mac]s vnet=%[vnet]s vlan=%[vlan]d vxlan=%[vxlan]d port=%[port]d tunnel=%[tunnel]s result=%[result]s |
11400 |
Remove invalid layer 2 entry in hardware (incorrect HW entry) |
Warn |
congestion_on_port |
Congestion detected on port=%[port]d |
11401 |
Congestion detected on port. Positive icongdrop/ocongdrop |
Critical |
congestion_relieved_on_port |
Congestion relieved on port=%[port]d |
11402 |
Congestion relieved on port. |
Critical |
fabric_node_status |
%[node_name]s: Node status changed to %[status]s |
11403 |
fabric node state change |
Note |
mld_disabled |
Disabling MLD on vlan: vlan=%[vlan]d |
11404 |
Disabling MLD on vlan |
Note |
mld_enabled |
Enabling MLD on vlan: vlan=%[vlan]d |
11405 |
Enabling MLD on vlan |
Note |
vlan_public_id_mismatch |
vnet=%[vnet]s vlan=%[vlan]d public-id mismatch while cluster offline |
11406 |
while cluster was offline vlan public-id mismatch happened |
Error |
vlan_port_node_ignored |
Ignoring offline cluster node name=%[name]s while assigning public vlan to vnet=%[vnet]s vlan=%[vlan]d |
11407 |
ignored offline cluster for private vlan port assignment |
Warn |
vlan_public_id_fail |
failed to set public-vlan for vnet=%[vnet]s vlan=%[vlan]d msg=%[msg]s |
11408 |
failed to set public vlan id while handling cluster status update |
Error |
bad_xcvr_detected |
unable to access I2C bus; possible bad transceiver |
11409 |
unable to access I2C bus; possibly a bad transceiver is inserted |
Error |
tacacs_server_error |
server=%[server]s TACACS+ authorization disabled due to repeated server errors |
11414 |
Repeated TACACS+ server errors. TACACS+ authorization disabled |
Critical |
tacacs_server_ok |
server=%[server]s TACACS+ authorization enabled due to server errors resolved |
11415 |
TACACS+ server has recovered from errors. TACACS+ Authorization enabled. |
Note |
dhcp_untrusted_msg |
DHCP server message received from untrusted port=%[port]d server-ip=%[ip]I |
11416 |
received DHCP server message from an untrusted port received DHCP server message from an untrusted port. |
Warn |
fabric_guard_loop_detect |
Fabric-guard detected loop |
11422 |
Fabric-guard detected a loop on port %[port]d. Port blocked. |
Note |
replace_offline_node |
loc-id=%[loc_id]d: node=%[name]s node-id=%[node_id]d replacing old-node=%[old_name]s old-node-id=%[old_node_id]d |
11423 |
new node replacing offline node with the same location id. |
Note |
loc_id_conflict |
loc-id=%[loc_id]d owned by node=%[name]s node-id=%[node_id]d, ignore message from conflict-node=%[old_name]s conflict-node-id=%[old_node_id]d |
11424 |
two nodes with the same loc-id is not allowed, ignoring latest |
Warn |
ntp_server_sync |
NTP server is unresolvable/unreachable |
11431 |
NTP server not resolvable/reachable |
Critical |
xact_rollforward_ignore_error |
Transactions rollforward tid=%[tid]d cmd=%[cmd]s failed result=%[result]R, ignoring error |
11432 |
xact rollforward failure overridden by user |
Warn |
xact_rollback_ignore_error |
Transactions rollback tid=%[tid]d cmd=%[cmd]s failed result=%[result]R, ignoring error |
11433 |
xact rollback failure overridden by user |
Warn |
nxu_module_fw_upgrade |
Installed version: %[inst]s; available version %[avail]s |
11434 |
One or more Lutera xcvrs require module firmware upgrade |
Warn |
nxu_chipset_fw_upgrade |
Installed version: %[inst]s; available version %[avail]s |
11435 |
One or more Lutera xcvrs require chipset firmware upgrade |
Warn |
sensor_unavailable |
sensor %[name]s cannot be accessed |
11436 |
sensor cannot be read by BMC |
Warn |
ipv6_raguard_ra_port_drop |
Dropping RA from port=%[port]d. %[msg]s |
11504 |
Drop RA packet from port according to RA Guard Policy |
Warn |
ipv6_raguard_ra_port_drop |
Dropping RA from vlan=%[vlan]d. %[msg]s |
11505 |
Drop RA packet from vlan according to RA Guard Policy |
Warn |
disk_health_below_RMA |
The disk health level %[current]d is significantly below recommended level %[rma]d, please notify Pluribus TAC immediately |
11514 |
The disk health is below the minimum required to work needs to be RMAed |
Critical |
disk_health_below_minimum |
The disk health level %[current]d is below recommended level %[rma]d, please notify Pluribus TAC |
11515 |
The disk health is below the minimum required to work |
Critical |
disk_health_filesystem_readonly |
The filesystem %[part]s is in Read Only mode, please notify Pluribus TAC immediately |
11516 |
The disk partition is mounted read-only |
Critical |
SI_setting_update |
Changed SIsetting forport(s) %[pmap]sto %[cbl_type] |
11517 |
User has set explicit port cable type |
Warn |
normal_space |
Disk Space Usage is normal below 70 percent |
11518 |
Disk space usage is normal |
Warn |
SI_setting_update |
Changed SI setting for port(s) %[pmap]s to %[cbl_type]s |
11519 |
User has set explicit port cable type |
Warn |
unsupported_platform |
not supported |
11520 |
message: Support for this hardware was deprecated starting with nvOS %[eos]s and later.Please review the Release Notes for this and previous releases to find the list of supported hardware |
Warn |
fabric_password_update |
%[node_name]s: %[msg]s |
11522 |
Password reset or changed |
Note |
excess_mac_move |
Excess MAC moves detected for mac=%[mac]M, vnet=%[vnet]s vlan=%[vlan]d vxlan=%[vxlan]d |
11523 |
Excess MAC moves detected |
Note |
excess_ip_move |
Excess IP moves detected for ip=%[ip]I vnet=%[vnet]s vlan=%[vlan]d vxlan=%[vxlan]d |
11524 |
Excess IP moves detected |
Note |
clear_excess_mac_move |
Excess MAC move condition cleared for mac=%[mac]M, vnet=%[vnet]s vlan=%[vlan]d vxlan=%[vxlan]d |
11525 |
Excess MAC move condition cleared |
Note |
clear_excess_ip_move |
Excess IP move condition cleared for ip=%[ip]I vnet=%[vnet]s vlan=%[vlan]d vxlan=%[vxlan]d |
11526 |
Excess IP move condition cleared |
Note |
port_oir_error_enter |
Port=%[port]d enter xcvr oir error state |
11527 |
Port enter xcvr oir error state |
Warn |
port_oir_error_exit |
Port=%[port]d exit xcvr oir error state |
11528 |
Port exit xcvr oir error state |
Warn |
port_oir_error_exit |
Port=%[port]d exit xcvr oir error state |
11529 |
Port exit xcvr oir error state |
Warn |
maintenance_disabled |
System is in Operational mode |
11530 |
system state is operational (maintenance-disabled) |
Note |
current_date_and_time |
Current date and time: %[timestr]s |
11539 |
log the previous date and time and origin |
Info |
new_date_and_time |
New date and time: %[timestr]s |
11540 |
log the new date and time and origin |
Info |
syslog_send_failed |
Failed to send log message to syslog server server(s) error-message(s) |
20000 |
Probable resource exhaustion on UDP socket. |
Error |
syslog_hostname_lookup_failed |
Failed to resolve hostname host(s) for syslog error-message(s) |
20001 |
Possible DNS problems or incorrect hostname for syslog server. |
Error |
system_repeats |
Last ids message(s) repeated number times(s) |
20002 |
Compress repeated messages |
Note |
reset_counters |
system log counters reset timestamp %[timestamp]s |
20005 |
Reset system log counters. |
Note |
syslog_tls_server_down |
tcp-tls connection to syslog server=%[server]s down. Logs are not getting exported |
20006 |
Connection to syslog export tcp/tls server is down. syslog export to external server is not happening. |
Error |
syslog_tls_server_restored |
tcp-tls connection to syslog server=%[server]s restored. Log export is operational |
20007 |
Connection to syslog export tcp/tls server is restored. |
Note |
syslog_tls_server_dropped |
syslog export log messages to syslog server=%[server]s getting dropped |
20008 |
Syslog export message(s) to tcp/tls server dropped. |
Error |
syslog_tls_server_delayed |
syslog export log messages to syslog server=%[server]s getting delayed |
20009 |
Syslog export message(s) to tcp/tls server delayed. |
Error |
generic_platform_audit |
platform audit message: %[msg]s |
20010 |
Platform audit message |
Note |
container_log |
container log message: %[msg]s |
20011 |
Logs from the containers |
Note |
os_logs |
OS audit log message: %[msg]s |
20012 |
Logs from the Operating system auditing |
Note |
mon_start |
nvOS_mon startup |
30000 |
Monitoring starting. |
Note |
mon_exit |
Exiting because reason(s) |
30001 |
Monitoring exiting for various reasons. |
Warn |
mon_reboot |
Starting command cmd(s) |
30004 |
Monitoring starting |
Note |
mon_restart_nvOSd |
Monitor restarting nvOSd |
30005 |
Restarting nvOSd |
Note |
mon_failure_detected |
Monitor detected failure failure(s) |
30006 |
Monitor detected a failure. |
Warn |
mon_reset |
Reset nvOSd config |
30007 |
nvOS_mon is resetting nvOSd configuration. |
Note |
mon_grub_gen |
Regenerating grub configuration for new boot environment. |
30008 |
nvOS_mon is regenerating grub. |
Note |
mon_restart_tomcat |
Monitor restarting tomcat. |
30009 |
Restarting tomcat. |
Note |
mon_cpu_usage_high |
High cpu usage detected. |
30010 |
High CPU usage detected. |
Note |
mon_memory_usage_high |
High memory usage detected |
30011 |
high memory usage detected. |
Note |
mon_disable_ports |
nvOSd cannot be revived; disabling ports to prevent headless switching. |
30012 |
Monitor failed to restart nvOSd; disabling ports to prevent headless switching. |
Critical |
mon_auth_failed |
User authorization failed for user name(s), pid pid(d), ip |
30013 |
User authorization failed. |
Note |
mon_keepalive_hung |
nvOS_mon is possibly stuck ! %[action]s |
30014 |
nvOS_mon keepalive_checker thread is possibly hung. |
Critical |
mon_autoreboot_cancel |
%[reason]s; the system will not be rebooted. |
30015 |
System will not be rebooted; auto-reboot is disabled or software-upgrade is in progress. |
Critical |
mon_autoreboot_failed |
System failed to auto-reboot: %[reason]s |
30016 |
System failed to auto-reboot: %[reason]s |
Critical |
mon_cpu_usage_higher_than_seventy |
CPU usage higher than 70 percent detected |
30017 |
CPU usage higher than 70 percent detected |
Critical |
mon_memory_usage_higher_than_seventy |
Memory usage higher than 70 percent detected |
30018 |
Memory usage higher than 70 percent detected |
Warn |
mon_memory_usage_lower_than_sixtyfive |
Memory usage is normal, lower than 65(%[mem].2f) percent detected |
30019 |
Memory usage is normal, lower than 65 percent detected |
Warn |
mon_memory_usage_higher_than_eighty |
Memory usage higher than 80 percent detected |
30020 |
Memory usage higher than 80 percent detected |
Warn |
mon_memory_usage_higher_than_ninety |
Memory usage higher than 90 percent detected |
30021 |
Memory usage higher than 90 percent detected |
Warn |
fanmon_fan_status |
Controller controller-id fan fan-id speed rpm RPM |
31000 |
Status of a fan after it becomes active |
Note |
fanmon_fan_missing |
Controller controller-id fan fan-id is missing |
31001 |
There is no fan in the fan slot |
Warn |
fanmon_fan_status_max |
Controller controller-id fan fan-id is max |
31002 |
Fan is set to maximum speed. |
Note |
fanmon_fan_fault |
Controller controller-id fan fan-id fault:fault(s) |
31003 |
There is a problem with the fan. |
Warn |
fanmon_fan_fault_compensate |
One fan fault is detected so setting all other fans to max speed to compensate. |
31004 |
One fan is faulty on the system. |
Warn |
fanmon_poweroff |
Fan monitor powering down system due to faults or over temp. |
31005 |
Fans are not working properly on the server-switch. |
Critical |
smf_nvOSd_start |
smf starting nvOS |
31007 |
nvOS starting |
Note |
smf_nvOSd_stop |
smf stopping nvOS |
31008 |
nvOS stopping. |
Note |
hw_route_prec0_detected |
F64 count=%[count]d hardware routes with invalid precedence detected |
31011 |
Aquila hardware route with invalid precedence detected |
Critical |
fanmon_fan_info |
Current temp %[temp]d Current speed %[rpm]d RPM |
31015 |
Show current temperature and Fan Speed setting info |
Note |
hwmon_start |
=== nvOSd_hwmon start === |
32000 |
nvOSd_hwmon startup |
Note |
hwmon_exit |
exiting because %[reason]s |
32001 |
hardware monitor exiting for some reason |
Warn |
hwmon_power_supply_fault |
power supply %[name]s fault |
32002 |
power supply has failed |
Critical |
hwmon_power_supply_ok |
power supply %[name]s has recovered from faulted state |
32003 |
power supply OK |
Note |
hwmon_fan_fault |
fan %[name]s fault |
32004 |
fan has failed |
Critical |
hwmon_fan_ok |
fan %[name]s has recovered from faulted state |
32005 |
fan ok |
Note |
hwmon_sensor_fault |
temperature sensor %[name]s fault |
32006 |
temperature sensor fault |
Warn |
hwmon_sensor_ok |
temperature sensor %[name]s has recovered from faulted state |
32007 |
temperature sensor ok |
Note |
hwmon_temp_warning |
%[name]s at %[t1]dC, shutdown at %[t2]dC |
32008 |
high temperature warning |
Warn |
hwmon_temp_Critical |
%[name]s at %[t1]dC, shutdown at %[t2]dC |
32009 |
high temperature Critical |
Critical |
hwmon_temp_shutdown |
shutting down system: %[name]s at %[t1]dC |
32010 |
high temperature system shutdown |
Critical |
hwmon_shutdown_failed |
system high temperature shutdown failed |
32011 |
high temperature system shutdown failed |
Critical |
hwmon_temp_ok |
%[name]s at %[t1]dC, temperature ok |
32012 |
temperature OK |
Note |