System Log Messages


Version 6.1.1-6010118491


Identifier

Message

Code

Description

Severity

system_drop

Lost drops-id msgs

10002

Unable to deliver system log(s) to nvlogd so system logs dropped.

Warn

update_find_server_failed

Failed to contact update server.

11006

Failed to find update server.

Warn

update_wrong_redirect

Unexpected redirect url(s) from update server.

11007

Got an unexpected redirect from HTTP update server lookup.

Warn

nvOSd_start

nvOSd start: version=version(s) changeset=changeset(s) branch=branch(s)

11008

nvOSd startup

Note

pkt_alloc_failed

feature(s) failed to allocate a send buffer.

11009

Failed to allocate a packet for sending from the CPU

Warn

syscall_failed_Critical

feature(s): syscall(s) failed: error

11012

A system call failed.

Critical

resstart_nvOSd

Restarting exe(s)

11013

Restarting nvOSd.

Note

restart_nvOSd_failed

Failed to restart exe(s): error-mgs

11014

Failed to restart nvOSd

Critical

nvOSd_init_failed

nvOSd failed to start: feature(s): error-mgs

11015

nvOSd was unable to start.

Critical

loop_detected

LOOP: mac(s) vlan(s) was on port_type(s) old_port-id ((ip(s)), now new_port-id) ((new_ip(s))

11016

Detected an L2 loop.

Note

mac_moved

MOVING MAC mac(s), from old_port_type(s) old_port-id (old_ip(s)) new_port_type(s) new_port-id (new_ip(s))

11017

MAC moved from one port to another.

Note

simulator_mode

Failed to init switch hardware.

11018

Simulator mode entered but not from command line.

Critical

fabric_joined

Joined fabric fabname(s).

11019

Switch joined a fabric.

Note

fabric_unjoined

Unjoined fabric fabname(s)

11020

Switch un-joined a fabric.

Note

config_imported

Imported configuration from file(s).

11021

Imported a new configuration.

Note

stp_switch_enable_failed

STP failed to initialize for switch hardware.

11028

STP initialization for underlying hardware switch failed.

Critical

stp_default_spanning_tree_failed

STP Failed to Create Default Spanning Tree: vlan= vlan-id

11029

Unable to create the Spanning Tree for default VLAN.

Critical

stp_flow

STP Failed to install flow(s) fpr BPDU reception: flow(s)

11030

Unable to install STP flow(s) for the reception of STP packets.

Critical

stp_worker_thread_failed

STP failed to create worker thread: vlan=vlan-id

11031

STP was unable to create worker thread for Spanning Tree.

Critical

stp_config_failed

Loading and application STP configuration failed.

11041

The loading and application of STP configuration failed.

Warn

stp_switch_port_state

STP Port Failure: port=port vlan=vlan-id trunk=trunk-id

11045

Unable to set the port state for the port on the VLAN.

Critical

stp_trunk_port_state

STP Set Port State: port vlan trunk

11046

Invalid trunk in use by the spanning tree

Warn

igmp_switch_init

IGMP snooping unable to initialize switch hardware for groups.

11047

igmp was unable to initialize switch hardware for the group.

Critical

igmp_flow_add

IGMP snooping unable to add flow flow(s).

11048

igmp was unable to add a flow for IGMP packet processing.

Warn

igmp_flow_remove

IGMP snooping not able to remove flow flow(s).

11049

IGMP snooping unable to remove flow for IGMP processing.

Warn

igmp_query_start

IGMP snooping unable to start query state machine.

11050

IGMP snooping unable to start query state machine.

Warn

igmp_query_stop

IGMP snooping unable to stop query state machine.

11051

IGMP snooping unable to stop query state machine.

Warn

igmp_switch_fini

IGMP snooping unable to halt switch hardware for groups.

11052

IGMP snooping unable to halt switch hardware for groups.

Warn

igmp_static_load

IGMP snooping unable to load static IGMP group.

11053

IGMP snooping unable to load static IGMP group.

Warn

igmp_static_source_load

IGMP snooping unable to load static IGMP source list.

11054

IGMP snooping unable to load static IGMP source list.

Warn

igmp_flooding

IGMP flooding not enabled.

11055

IGMP flooding not enabled.

Warn

igmp_group_add_failed

IGMP Group Add Failed: vlan-id group(s)

11071

IGMP snooping failed to add a group to switch hardware.

Warn

igmp_group_remove_failed

IGMP Group Remove Failed: vlan-id group(s)

11072

IGMP snooping failed to remove a group from switch hardware.

Warn

software_upgrade_initiated

nvOS software upgrade initiated for version(s).

11073

Software upgrade initiated; downloading and installing new packages.

Note

software_upgrade_complete

System and nvOS software upgrade complete version(s).

11074

System and nvOS software upgrade complete.

Note

software_upgrade_failed

nvOS software upgrade failed.

11075

nvOS software upgrade failed.

Warn

system_reboot

System reboot initiated by nvOS.

11076

System reboot initiated by nvOS.

Note

system_reboot_failed

System reboot initiated by nvOSd failed.

11077

System reboot initiated by nvOSd failed.

Warn

lldp_agent_create_thread_failed

LLDP Agent Thread Create Failed: mac(s) group(s) error

11079

Creation of threads for LLDP Agent failed.

Warn

lldp_flow_add_failed

LLDP Flow Add Failed: flow(s)

11080

Adding flow for LLDP packet reception failed.

Warn

lldp_flow_remove_failed

LLDP Flow Remove Failed: flow(s)

11081

Removing flow for LLDP packet reception failed.

Warn

evb_platform_not_supported

EVB is not supported on this platform: port

11089

EVB is not supported on this platform.

Warn

evb_ecp_not_enabled

EVB ECP is Not Enabled: port

11090

Received EVB TLV with ECP is not enabled.

Warn

evb_flow_remove_failed

EVB Flow Remove Failed: flowstr(s)

11095

Unable to remove specified EVB flow.

Warn

lldp_agent_create_failure

LLDP Agent Create Failed: agent(s)

11111

Failed to create LLDP agent for one of three agent addresses.

Warn

stats_log_open_failed

Log file open failed.

11140

The log file failed to open.

Warn

container_rebuild_start

container=%[container]s rebuild is started

11141

container rebuild is started

Warn

container_rebuild_end

container=%[container]s rebuild is completed

11142

container rebuild is completed

Warn

all_container_rebuild

all containers are rebuilt

11143

all containers are rebuilt

Warn

loop_broken

A loop was broken on port/vlan for mac/ip

11180

A loop was broken on a port or VLAN for a MAC or IP address

Warn

loop_stp

A loop was detected that STP should have prevented.

11181

STP did not prevent a loop on the network.

Warn

update_auto_upgrade

Update server initiated upgrade

11210

The update server initiated an upgrade for nvOS.

Note

update_error

Update server sent an error message

11211

The update server sent an error message.

Warn

ps_initial_status

Power supply initial status.

11302

The initial status of the power supplies.

Warn

fan_initial_status

Fan initial status

11303

The initial status of the fans.

Warn

ps_status_change

Power supply state change

11304

The status of the power supplies changed.

Warn

fan_status_change

Fan status change

11305

The status of the fans changed.

Warn

fabric_node_duplicate_ip

Fabric node has the same ip=%[ip]I as the local node, cannot send to it

11319

Fabric node has the same IP as the local node, cannot send to it.

Warn

upgrade_error

software upgrade error: %[name]s: %[func]s - %[err]s

11324

Software Upgrade errors

Warn

upgrade_informational

software upgrade Note: %[name]s: %[func]s - %[info]s

11325

Software Upgrade informational messages

Note

upgrade_reboot

System reboot initiated by upgrade agent

11326

System reboot initiated by software upgrade

Note

upgrade_reboot_failed

System reboot initiated by upgrade agent failed

11327

System reboot initiated by software upgrade failed

Warn

openstack_nat_failed

Failed to setup NAT on the OpenStack controller %[name]s

11328

Failed to configure NAT for OpenStack

Warn

mac_tunnel_to_port

MOVING MAC=%[mac]M, vlan=%[vlan]d from tunnel=%[tunnel]s ip=%[old_ip]I to port=%[port]d ip=%[new_ip]I %[caller]s

11329

MAC moved from a tunnel to a port

Warn

mac_port_to_switch

MOVING MAC=%[mac]M, vlan=%[vlan]d from switch=%[old_sw]s port=%[old_port]d ip=%[old_ip]I to switch=%[new_sw]s port=%[new_port]d ip=%[new_ip]I %[caller]s

11330

MAC moved from a port to another switch

Note

mld_flow_add

mld snooping unable to add flow: flow=%[flow]s

11341

MLD was unable to add a flow for MLD packet processing

Warn

mld_flow_remove

mld snooping not able to remove flow: flow=%[flow]s

11342

MLD snooping unable to remove flow for MLD processing

Warn

mld_query_start

mld snooping unable to start query state machine

11343

MLD snooping unable to start query state machine.

Warn

mld_query_stop

mld snooping unable to stop query state machine

11344

MLD was not able to stop the query state machine.

Warn

mld_static_load

mld snooping unable to load static mld group

11345

MLD snooping unable to load static MLD group.

Warn

mld_static_source_load

mld snooping unable to load static mld group source list

11346

MLD snooping unable to load static mld group source list.

Warn

xact_node_ignored

Ignoring offline cluster node name=%[name]s for transaction tid=%[tid]d

11366

ignored offline cluster node for transaction.

Warn

xact_recover

Transactions out-of-sync detected, rolled forward from old=%[old]d to new=%[new]d via node=%[node]s

11367

auto-recovered from transactions being out of sync.

Warn

xact_recover_failed

Transaction auto-recover failed: %[msg]s

11368

auto-recover attempted but failed

Warn

ip_moved

Moving ip=%[ip]I from old-mac=%[old_mac]M to new-mac=%[new_mac]M

11369

IP address moved from one MAC to another MAC

Note

software_license_expiring

software license(s) expiring soon code=%[code]s expires_on=%[expires_on]s

11370

software license(s) expiring

Warn

software_license_expired

software license(s) have expired code=%[code]s expired_on=%[expires_on]s

11371

software license(s) have expired

Warn

l2_check_missing

Add missing l2 entry to hardware: mac=%[mac]s vlan=%[vlan]d vxlan=%[vxlan]d port=%[port]d result=%[result]s

11376

Add layer 2 entry that was missing in hardware

Warn

l2_check_bad_port

Fix l2 entry in hardware with incorrect port: mac=%[mac]s vlan=%[vlan]d vxlan=%[vxlan]d old_port=%[old_port]d new_port=%[new_port]d result=%[result]s

11377

Fix layer 2 entry in hardware with incorrect port

Warn

l2_check_orphaned

Remove orphaned l2 entry from hardware: mac=%[mac]s vlan=%[vlan]d vxlan=%[vxlan]d port=%[port]d result=%[result]s

11378

Remove orphaned layer 2 entry in hardware (not in software table)

Warn

mac_move_denied

MOVE DENIED mac=%[mac]M vlan=%[vlan]d vxlan=%[vxlan]d from switch=%[sw]n port=%[port]d to deny-switch=%[deny_sw]n deny-port=%[deny_port]d reason=%[reason]s

11379

Mac moved not allowed

Note

host_port_loop_detected

Looping traffic detected on host-port=%[port]d vlan=%[vlan]d. Traffic on this port/VLAN will be ignored until loop resolved

11380

loop detected on host port

Warn

host_port_loop_resolved

Traffic has stopped looping on host-port=%[port]d vlan=%[vlan]d

11381

loop on host port is no longer happening

Note

owner_mac_moved

caller=%[caller]s owner=%[owner]n mac=%[mac]M vlan=%[vlan]d moved from old-local-port=%[old_port]d to new-local-port=%[new_port]d

11382

other switch's mac moved from one local port to another

Note

mstp_set_port_state_failed

STP Port State Failure: port=%[port]d instance=%[instance]d

11384

Unable to set the stp state for the port on the MST instance

Critical

mac_port_to_tunnel

MOVING MAC=%[mac]M, vnet=%[vnet]s vlan=%[vlan]d from port=%[port]d ip=%[old_ip]I to tunnel=%[tunnel]s ip=%[new_ip]I %[caller]s

11385

mac moved from a port to a tunnel

Note

cluster_vlag_l2_update_failed

Updating mac=%[mac]M vnet=%[vnet]s vlan=%[vlan]d from peer update to vlag port port=%[port]d failed, cluster may be out-of-sync: reason=%[reason]

11386

updating mac to vlag port in response to peer status update failed, cluster L2 may be out of sync

Warn

cluster_tunnel_l2_update_failed

Updating mac=%[mac]M vxlan=%[vxlan]d tunnel=%[tunnel]s from peer update failed, cluster may be out-of-sync: reason=%[reason]s

11387

updating tunnel mac in response to peer status update failed, cluster L2 may be out of sync

Warn

cluster_comm_l2_update_failed

Updating mac=%[mac]M vnet=%[vnet]s vlan=%[vlan]d from peer update to cluster port port=%[port]d failed, cluster may be out-of-sync: reason=%[reason]s

11388

updating mac to cluster link in response to peer status update failed, cluster L2 may be out of sync

Warn

l2_check_bad_tunnel

Fix l2 entry in hardware with incorrect tunnel: mac=%[mac]s vnet=%[vnet]s vlan=%[vlan]d vxlan=%[vxlan]d old_tunnel=%[old_tunnel]s new_tunnel=%[new_tunnel]s result=%[result]s

11389

Fix layer 2 entry in hardware with incorrect tunnel

Note

l2_check_mismatch_vport

Mismatched vport entry: mac=%[mac]s vlan=%[vlan]d vxlan=%[vxlan]d hw_vlan=%[hw_vlan]d hw_vxlan=%[hw_vxlan]d result=%[result]s

11390

Mismatched vport entry

Note

l2_check_mark_port_mac

Marked vport as port-mac: mac=%[mac]s vlan=%[vlan]d vxlan=%[vxlan]d

11391

Marked owned local vport as port-mac

Warn

l2_check_delete_port_mac

Delete invalid port-mac vport: mac=%[mac]s vlan=%[vlan]d vxlan=%[vxlan]d

11392

Delete port-mac that should not be in vport table

Warn

hostid_collision_detected

Our hostid is being used by another node %[node_name]s

11393

received keep-alive from another node having same hostid

Critical

mirror_to_cpu_configured

Mirror to CPU configured on vFlow %[vflow_name]s

11395

Mirror to CPU configured

Note

low_disk_space

Disk Space Usage has exceeded threshold of 70 percent

11396

Disk space usage exceeds 70 percent

Warn

stp_vnet_port_recv

received STP BPDU on vnet port: port=%[port]d

11397

received an STP BPDU on a vnet port

Warn

igmp_disabled

Disabling IGMP on vlan: vlan=%[vlan]d

11398

Disabling IGMP on vlan

Note

igmp_enabled

Enabling IGMP on vlan: vlan=%[vlan]d

11399

Enabling IGMP on vlan

Note

l2_check_hw_invalid

Remove invalid l2 entry from hardware: mac=%[mac]s vnet=%[vnet]s vlan=%[vlan]d vxlan=%[vxlan]d port=%[port]d tunnel=%[tunnel]s result=%[result]s

11400

Remove invalid layer 2 entry in hardware (incorrect HW entry)

Warn

congestion_on_port

Congestion detected on port=%[port]d

11401

Congestion detected on port. Positive icongdrop/ocongdrop

Critical

congestion_relieved_on_port

Congestion relieved on port=%[port]d

11402

Congestion relieved on port.

Critical

fabric_node_status

%[node_name]s: Node status changed to %[status]s

11403

fabric node state change

Note

mld_disabled

Disabling MLD on vlan: vlan=%[vlan]d

11404

Disabling MLD on vlan

Note

mld_enabled

Enabling MLD on vlan: vlan=%[vlan]d

11405

Enabling MLD on vlan

Note

vlan_public_id_mismatch

vnet=%[vnet]s vlan=%[vlan]d public-id mismatch while cluster offline

11406

while cluster was offline vlan public-id mismatch happened

Error

vlan_port_node_ignored

Ignoring offline cluster node name=%[name]s while assigning public vlan to vnet=%[vnet]s vlan=%[vlan]d

11407

ignored offline cluster for private vlan port assignment

Warn

vlan_public_id_fail

failed to set public-vlan for vnet=%[vnet]s vlan=%[vlan]d msg=%[msg]s

11408

failed to set public vlan id while handling cluster status update

Error

bad_xcvr_detected

unable to access I2C bus; possible bad transceiver

11409

unable to access I2C bus; possibly a bad transceiver is inserted

Error

tacacs_server_error

server=%[server]s TACACS+ authorization disabled due to repeated server errors

11414

Repeated TACACS+ server errors. TACACS+ authorization disabled

Critical

tacacs_server_ok

server=%[server]s TACACS+ authorization enabled due to server errors resolved

11415

TACACS+ server has recovered from errors. TACACS+ Authorization enabled.

Note

dhcp_untrusted_msg

DHCP server message received from untrusted port=%[port]d server-ip=%[ip]I

11416

received DHCP server message from an untrusted port received DHCP server message from an untrusted port.

Warn

fabric_guard_loop_detect

Fabric-guard detected loop

11422

Fabric-guard detected a loop on port %[port]d. Port blocked.

Note

replace_offline_node

loc-id=%[loc_id]d: node=%[name]s node-id=%[node_id]d replacing old-node=%[old_name]s old-node-id=%[old_node_id]d

11423

new node replacing offline node with the same location id.

Note

loc_id_conflict

loc-id=%[loc_id]d owned by node=%[name]s node-id=%[node_id]d, ignore message from conflict-node=%[old_name]s conflict-node-id=%[old_node_id]d

11424

two nodes with the same loc-id is not allowed, ignoring latest

Warn

ntp_server_sync

NTP server is unresolvable/unreachable

11431

NTP server not resolvable/reachable

Critical

xact_rollforward_ignore_error

Transactions rollforward tid=%[tid]d cmd=%[cmd]s failed result=%[result]R, ignoring error

11432

xact rollforward failure overridden by user

Warn

xact_rollback_ignore_error

Transactions rollback tid=%[tid]d cmd=%[cmd]s failed result=%[result]R, ignoring error

11433

xact rollback failure overridden by user

Warn

nxu_module_fw_upgrade

Installed version: %[inst]s; available version %[avail]s

11434

One or more Lutera xcvrs require module firmware upgrade

Warn

nxu_chipset_fw_upgrade

Installed version: %[inst]s; available version %[avail]s

11435

One or more Lutera xcvrs require chipset firmware upgrade

Warn

sensor_unavailable

sensor %[name]s cannot be accessed

11436

sensor cannot be read by BMC

Warn

ipv6_raguard_ra_port_drop

Dropping RA from port=%[port]d. %[msg]s

11504

Drop RA packet from port according to RA Guard Policy

Warn

ipv6_raguard_ra_port_drop

Dropping RA from vlan=%[vlan]d. %[msg]s

11505

Drop RA packet from vlan according to RA Guard Policy

Warn

disk_health_below_RMA

The disk health level %[current]d is significantly below recommended level %[rma]d, please notify Pluribus TAC immediately

11514

The disk health is below the minimum required to work needs to be RMAed


Critical

disk_health_below_minimum

The disk health level %[current]d is below recommended level %[rma]d, please notify Pluribus TAC

11515

The disk health is below the minimum required to work

Critical

disk_health_filesystem_readonly

The filesystem %[part]s is in Read Only mode, please notify Pluribus TAC immediately

11516

The disk partition is mounted read-only

Critical

SI_setting_update

Changed SIsetting forport(s) %[pmap]sto %[cbl_type]

11517

User has set explicit port cable type

Warn

normal_space

Disk Space Usage is normal below 70 percent

11518

Disk space usage is normal

Warn

SI_setting_update

Changed SI setting for port(s) %[pmap]s to %[cbl_type]s

11519

User has set explicit port cable type

Warn

unsupported_platform

not supported

11520

message: Support for this hardware was deprecated starting with nvOS %[eos]s and later.Please review the Release Notes for this and previous releases to find the list of supported hardware

Warn

fabric_password_update

%[node_name]s: %[msg]s

11522

Password reset or changed

Note

excess_mac_move

Excess MAC moves detected for mac=%[mac]M, vnet=%[vnet]s vlan=%[vlan]d vxlan=%[vxlan]d

11523

Excess MAC moves detected

Note

excess_ip_move

Excess IP moves detected for ip=%[ip]I vnet=%[vnet]s vlan=%[vlan]d vxlan=%[vxlan]d

11524

Excess IP moves detected

Note

clear_excess_mac_move

Excess MAC move condition cleared for mac=%[mac]M, vnet=%[vnet]s vlan=%[vlan]d vxlan=%[vxlan]d

11525

Excess MAC move condition cleared

Note

clear_excess_ip_move

Excess IP move condition cleared for ip=%[ip]I vnet=%[vnet]s vlan=%[vlan]d vxlan=%[vxlan]d

11526

Excess IP move condition cleared

Note

port_oir_error_enter

Port=%[port]d enter xcvr oir error state

11527

Port enter xcvr oir error state

Warn

port_oir_error_exit

Port=%[port]d exit xcvr oir error state

11528

Port exit xcvr oir error state

Warn

port_oir_error_exit

Port=%[port]d exit xcvr oir error state

11529

Port exit xcvr oir error state

Warn

maintenance_disabled

System is in Operational mode

11530

system state is operational (maintenance-disabled)

Note

current_date_and_time

Current date and time: %[timestr]s

11539

log the previous date and time and origin

Info

new_date_and_time

New date and time: %[timestr]s

11540

log the new date and time and origin

Info

syslog_send_failed

Failed to send log message to syslog server server(s) error-message(s)

20000

Probable resource exhaustion on UDP socket.

Error

syslog_hostname_lookup_failed

Failed to resolve hostname host(s) for syslog error-message(s)

20001

Possible DNS problems or incorrect hostname for syslog server.

Error

system_repeats

Last ids message(s) repeated number times(s)

20002

Compress repeated messages

Note

reset_counters

system log counters reset timestamp %[timestamp]s

20005

Reset system log counters.

Note

syslog_tls_server_down

tcp-tls connection to syslog server=%[server]s down. Logs are not getting exported

20006

Connection to syslog export tcp/tls server is down. syslog export to external server is not happening.

Error

syslog_tls_server_restored

tcp-tls connection to syslog server=%[server]s restored. Log export is operational

20007

Connection to syslog export tcp/tls server is restored.

Note

syslog_tls_server_dropped

syslog export log messages to syslog server=%[server]s getting dropped

20008

Syslog export message(s) to tcp/tls server dropped.

Error

syslog_tls_server_delayed

syslog export log messages to syslog server=%[server]s getting delayed

20009

Syslog export message(s) to tcp/tls server delayed.

Error

generic_platform_audit

platform audit message: %[msg]s

20010

Platform audit message

Note

container_log

container log message: %[msg]s

20011

Logs from the containers

Note

os_logs

OS audit log message: %[msg]s

20012

Logs from the Operating system auditing

Note

mon_start

nvOS_mon startup

30000

Monitoring starting.

Note

mon_exit

Exiting because reason(s)

30001

Monitoring exiting for various reasons.

Warn

mon_reboot

Starting command cmd(s)

30004

Monitoring starting

Note

mon_restart_nvOSd

Monitor restarting nvOSd

30005

Restarting nvOSd

Note

mon_failure_detected

Monitor detected failure failure(s)

30006

Monitor detected a failure.

Warn

mon_reset

Reset nvOSd config

30007

nvOS_mon is resetting nvOSd configuration.

Note

mon_grub_gen

Regenerating grub configuration for new boot environment.

30008

nvOS_mon is regenerating grub.

Note

mon_restart_tomcat

Monitor restarting tomcat.

30009

Restarting tomcat.

Note

mon_cpu_usage_high

High cpu usage detected.

30010

High CPU usage detected.

Note

mon_memory_usage_high

High memory usage detected

30011

high memory usage detected.

Note

mon_disable_ports

nvOSd cannot be revived; disabling ports to prevent headless switching.

30012

Monitor failed to restart nvOSd; disabling ports to prevent headless switching.

Critical

mon_auth_failed

User authorization failed for user name(s), pid pid(d), ip

30013

User authorization failed.

Note

mon_keepalive_hung

nvOS_mon is possibly stuck ! %[action]s

30014

nvOS_mon keepalive_checker thread is possibly hung.

Critical

mon_autoreboot_cancel

%[reason]s; the system will not be rebooted.

30015

System will not be rebooted; auto-reboot is disabled or software-upgrade is in progress.

Critical

mon_autoreboot_failed

System failed to auto-reboot: %[reason]s

30016

System failed to auto-reboot: %[reason]s

Critical

mon_cpu_usage_higher_than_seventy

CPU usage higher than 70 percent detected

30017

CPU usage higher than 70 percent detected

Critical

mon_memory_usage_higher_than_seventy

Memory usage higher than 70 percent detected

30018

Memory usage higher than 70 percent detected

Warn

mon_memory_usage_lower_than_sixtyfive

Memory usage is normal, lower than 65(%[mem].2f) percent detected

30019

Memory usage is normal, lower than 65 percent detected

Warn

mon_memory_usage_higher_than_eighty

Memory usage higher than 80 percent detected

30020

Memory usage higher than 80 percent detected

Warn

mon_memory_usage_higher_than_ninety

Memory usage higher than 90 percent detected

30021

Memory usage higher than 90 percent detected

Warn

fanmon_fan_status

Controller controller-id fan fan-id speed rpm RPM

31000

Status of a fan after it becomes active

Note

fanmon_fan_missing

Controller controller-id fan fan-id is missing

31001

There is no fan in the fan slot

Warn

fanmon_fan_status_max

Controller controller-id fan fan-id is max

31002

Fan is set to maximum speed.

Note

fanmon_fan_fault

Controller controller-id fan fan-id fault:fault(s)

31003

There is a problem with the fan.

Warn

fanmon_fan_fault_compensate

One fan fault is detected so setting all other fans to max speed to compensate.

31004

One fan is faulty on the system.

Warn

fanmon_poweroff

Fan monitor powering down system due to faults or over temp.

31005

Fans are not working properly on the server-switch.

Critical

smf_nvOSd_start

smf starting nvOS

31007

nvOS starting

Note

smf_nvOSd_stop

smf stopping nvOS

31008

nvOS stopping.

Note

hw_route_prec0_detected

F64 count=%[count]d hardware routes with invalid precedence detected

31011

Aquila hardware route with invalid precedence detected

Critical

fanmon_fan_info

Current temp %[temp]d Current speed %[rpm]d RPM

31015

Show current temperature and Fan Speed setting info

Note

hwmon_start

=== nvOSd_hwmon start ===

32000

nvOSd_hwmon startup

Note

hwmon_exit

exiting because %[reason]s

32001

hardware monitor exiting for some reason

Warn

hwmon_power_supply_fault

power supply %[name]s fault

32002

power supply has failed

Critical

hwmon_power_supply_ok

power supply %[name]s has recovered from faulted state

32003

power supply OK

Note

hwmon_fan_fault

fan %[name]s fault

32004

fan has failed

Critical

hwmon_fan_ok

fan %[name]s has recovered from faulted state

32005

fan ok

Note

hwmon_sensor_fault

temperature sensor %[name]s fault

32006

temperature sensor fault

Warn

hwmon_sensor_ok

temperature sensor %[name]s has recovered from faulted state

32007

temperature sensor ok

Note

hwmon_temp_warning

%[name]s at %[t1]dC, shutdown at %[t2]dC

32008

high temperature warning

Warn

hwmon_temp_Critical

%[name]s at %[t1]dC, shutdown at %[t2]dC

32009

high temperature Critical

Critical

hwmon_temp_shutdown

shutting down system: %[name]s at %[t1]dC

32010

high temperature system shutdown

Critical

hwmon_shutdown_failed

system high temperature shutdown failed

32011

high temperature system shutdown failed

Critical

hwmon_temp_ok

%[name]s at %[t1]dC, temperature ok

32012

temperature OK

Note

north
    keyboard_arrow_up
    keyboard_arrow_down
    description
    print
    feedback
    support
    business
    rss_feed
    south