port-config-show
This command is used to display port settings on the switch.
Syntax port-config-show
intf intf-number |
Displays the interface number. |
name name-string |
If configured, displays the name of the port. Otherwise, the field is blank. |
port port-list |
Displays a port or list of ports. |
speed disable|10m|100m|1g|2.5g|10g|25g|40g|50g|100g |
Displays the port speed. Ports configured for speeds of 1G must be equipped with SFP transceivers. Ports configured for 10G or higher must be equipped with SFP+ or QSFP+ transceivers. |
egress-rate-limit unlimited |
Displays the egress rate limit for the port. |
bw-bps bw-bps-number |
Specify the bandwidth bps for the port. |
eth-mode [sr4|lr4|cr4|caui4|sr|lr|cr] |
Displays the Ethernet mode. |
autoneg|no-autoneg |
Displays if the port auto-negotiates the port speed with a peer. |
jumbo|no-jumbo |
Displays if the port forwards jumbo frames. Jumbo frames are Ethernet frames with more than 1500 bytes of payload. |
enable|disable |
Displays if the port is enabled and forwards or drops frames. |
lacp-priority integer |
Displays the LACP priority for the port. This is a value between 1 and 65535 with a default value of 32768. |
reflect|no-reflect |
Displays if the port reflects frames received for loopback testing. |
edge-switch| |
Displays if the port connects to another Pluribus Networks device or is an uplink to a third-party switch or host. |
pause|no-pause |
Displays if the port traffic is paused or not. |
description description-string |
Displays a description for the port. |
loopback|no-loopback |
Displays to use loopback or no loopback. |
vxlan-termination|no-vxlan-termination |
Displays if a VXLAN terminates on a port. |
mirror-receive-only|no-mirror-receive-only |
Displays if you want the port to receive mirrored traffic only. |
vle vle name |
Displays the VLE on this port. |
trunk-hw-id trunk-hw-id-number |
DisplaysDisplaysDisplays the trunk hardware ID assigned.. |
trunk trunk-name |
Displays the trunk name for the port. |
vlag vlag-name |
Displays the VLAG for the port. |
send-port send-port-number |
Displays the port number to send in packets. |
loop-vlans vlan-list |
Displays the VLANs that are looping on the network. |
routing|no-routing |
Displays if the port is participating in routing on the switch. |
host-enable|host-disable |
Displays if you want host-facing ports enabled or disabled. |
crc-check-enable|crc-check-disable |
Displays if you want CRC checking performed by the port. This is applicable to a switch in Virtual Wire mode. The default value is crc-check-disable. |
defer-bringup|no-defer-bringup |
Specify if you want to delay port activation. |
dscp-map dscp-map name | none |
Displays a DSCP map name to enable on port. |
local-switching|no-local-switching |
Displays if local switching is allowed on the port. |
rhost rhost-string |
Displays the physical remote host. |
allowed-tpid q-in-q|q-in-q-old |
Specify the allowed TPID in addition to 0x8100 on VLAN header |
fabric-guard|no-fabric-guard |
Displays if you want loop detection enabled on the port. |
Defaults None.
Access CLI
History
Version 1.2 |
Command introduced. |
Version 1.2.6 |
The optional parameters for LACP added. |
Version 2.1 |
The parameters, loopback, mirror-receive, vlag-failover, and send-port added. |
Version 2.2.6 |
The parameter, egress-rate-limit, introduced. |
Version 2.3.1 |
Multiple parameters for LACP added. |
Version 2.4 |
The parameter, host-enable, and loop-vlans added. |
Version 2.4.1 |
The parameters, lacp-fallback, lacp-fallback-timeout and lacp-individual deprecated. |
Version 2.5.2 |
The parameter, crc-check-enable|crc-check-disable, introduced. |
Version 2.5.3 |
The parameters, reflect|no-reflect, vxlan-termination, dscp-map, and local-switching added. |
Version 2.6.0 |
The parameter, fabric-guard, and allowed-tpid, added. |
Version 3.0.0 |
The parameter, bw-bps, added. |
Version 5.1.0 |
The following parameter deprecated: • bw-bps The following parameters introduced: • additional Ethernet modes • defer-bringup|no-defer-bringup • fec|no-fec|fec-auto |
Usage Server-switches are equipped with network data ports for host or inter-switch communication. This command configures the settings of a specific network data port of all data ports on the local switch.
Examples To display information about all ports on a switch, use the following command:
CLI network-admin@switch > port-config-show
switch: pleiades25
intf: 10
name:
port: 10
speed: 10g
autoneg: off
jumbo: off
enable: on
lacp-priority: 32768
reflect: off
edge-switch: no
pause: no
description:
loopback: default
mirror_only: default
rswitch-default-vlan: 0
port-mac-address: 06:b0:00:02:30:0a