system-settings-show

This command allows you to display system settings that optimize Netvisor performance.

Syntax   system-settings-show

optimize-arps|no-optimize-arps

Enable or disable ARP optimization. 

lldp|no-lldp

Enable or disable LLDP discovery.

policy-based-routing|no-policy-based-routing

Enable or disable policy-based routing.

optimize-nd|no-optimize-nd

Enable or disable Neighbor Discovery optimization.

reactivate-mac|no-reactivate-mac

Enable or disable reactivation of aged out MAC entries.

reactivate-vxlan-tunnel-mac|no-reactivate-vxlan-tunnel-mac

Enable or disable enable reactivation of MAC entries over VXLAN tunnels.

manage-unknown-unicast|no-manage-unknown-unicast

Enable or disable unknown unicast management.

manage-broadcast|no-manage-broadcast

Enable or disable broadcast management. 

block-loops|no-block-loops

Enable or disable loop blocking.

Note: This parameter is available only on NSU, NRU-02, NRU-03, and NRU-S0301 platforms.

auto-trunk|no-auto-trunk

Enable or disable auto trunking.

auto-host-bundle|no-auto-host-bundle

Enable or disable host auto bundling.

cluster-active-active-routing|no-cluster-active-active-routing

Enable or disable active-active cluster routing.

fast-route-download|no-fast-route-download

Enable or disable fast route download from routesnoop.

fast-interface-lookup|no-fast-interface-lookup

Enable or disable fast router interface lookup.

routing-over-vlags|no-routing-over-vlags

Enable or disable routing to VLAGs from cluster links.

optimize-datapath disable|cluster-only|all

Specify the datapath optimization for cluster, fabric

and vRouter communication:

· disable: disables datapath optimization.

· cluster-only: enables datapath optimization

for cluster-only, where cluster traffic is

redirected to cluster 4094 vNIC.

· all: enables datapath optimization for fabric

and data traffic.

The default value is all.

source-mac-miss to-cpu|copy-to-cpu

Control unknown source MAC address learn behavior.

cpu-class-enable|no-cpu-class-enable

Enable or disable CPU class.

use-igmp-snoop-l2|use-igmp-snoop-l3

Use Layer 2 or Layer 3 tables for IGMP snooping.

vle-tracking-timeout seconds

Specify VLE tracking timeout in seconds from 3 to 30 seconds.

usb-port|no-usb-port

Enable or disable the USB port on the front of the switch. This is only applicable to switches with ONVL.

pfc-buffer-limit pfc-buffer-limit-string

Percentage of global system buffer space allowed for PFC.

cosq-weight-auto|no-cosq-weight-auto

Specify if you want to adjust queue weights automatically.

lossless-mode|no-lossless-mode

Specifies lossless mode.

stagger-queries|no-stagger-queries

Specify if you want to stagger sending IGMP queries on the network.

qsfp28-port-mode none|6x40G|4x100G

configure the QSFP28 port mode as 6x40G or 4x100G.

host-refresh|no-host-refresh

Specify if you want to enable refreshing host ARP entries to keep L2 entries active.

proxy-conn-retry|no-proxy-conn-retry

Enable or disable proxy connection retry.

proxy-conn-max-retry integer

Specify the maximum number of proxy connection retry attempts from 0 to 20.

proxy-conn-retry-interval mseconds

Specify the number of milliseconds, from 100 to 2000,   to wait between proxy connection retry attempts.

nvos-debug-logging|no-nvos-debug-logging

Specify the logging mode.

manage-l2-uuc-drop|no-manage-l2-uuc-drop

Enable or disable L2 Unknown Unicast Drop towards data port.

optimize-rxlos|no-optimize-rxlos

Enable or disable processing of port modules that do not support RXLOS.

xcvr-link-debug|no-xcvr-link-debug

Enable or disable receiver link debug.

fastpath-bfd|no-fastpath-bfd

Enable or disable BFD path optimization.

linkscan-interval 10000..1000000

Specify the linkscan interval as a value between 10000μs and 1000000μs. The default value is 150000μs.

Note: This parameter is not in effect when the link scan mode is hardware.

linkscan-mode software|hardware

Specify the link scan mode as hardware or software. Software link scan mode is enabled by default.

single-pass-l2-known-multicast|no-single-pass-l2-known-multicast

Specify to enable or disable single-pass forwarding of L2 known multicast traffic.

single-pass-flood|no-single-pass-flood

Enable or disable single-pass flood.

single-pass-riot enable|disable

Specify to enable or disable the switches to perform routing in and out of tunnels (RIOT) in a single pass (that is, without requiring the loopback trunk).

Note: This option is available only on NRU03 and NRU-S03 platforms and on the Dell S4100 and S5200 Series.

cos-8-and-9-queue|no-cos-8-and-9-queue

Enable or disable CoS queues 8 and 9.

batch-move-mac-hw-group-for-vlan-only|no-batch-move-mac-hw-group-for-vlan-only

Specify to enable or disable the HW batch move for MAC by group for VLAN network only.

offline-notification-new-thread|no-offline-notification-new-thread

Enables or disables new thread to send offline notifications when switch goes down.


Defaults   All parameters enabled by default.

Access   Network Administrator

History   

Version 2.5.2

Command introduced.

Version 2.5.3

The parameters, auto-host-trunk, and cluster-active-active-routing added.

Version 2.6.0

The parameters, policy-based-routing, auto-vlag-bundle, lldp, block-loops, source-mac-miss, cpu-class, igmp-snooping and usb added.

Version 3.0.0

The parameters, stagger-queries, cosq-weight-auto and vle-tracking-timeout, added.

Version 3.1.0

The parameters, host-refresh, proxy-conn-retry, proxy-conn-max-retry, proxy-conn-retry-interval, added.

Version 5.2.0

The parameter, fastpath-bfd|no-fastpath-bfd, added.

Version 6.0.0

The parameters, linkscan-mode, single-pass-flood, riot-single-pass added.

Version 6.0.1

The parameters cos-8-and-9-queue and batch-move-mac-hwgroup-for-vlan-only added.

Version 6.1.1

The parameters offline-notification-new-thread added.

Usage   Use this command to display system settings. However, it is recommended that you do not modify the settings without consulting Pluribus Networks.

Examples  To display system settings, use the following syntax:

CLI network-admin@switch > system-settings-show

optimize-arps:                         off

lldp:                                  on

policy-based-routing:                  off

optimize-nd:                           off

reactivate-mac:                        on

reactivate-vxlan-tunnel-mac:           on

manage-unknown-unicast:                off

manage-broadcast:                      off

block-loops:                           off

auto-trunk:                            on

auto-host-bundle:                      off

cluster-active-active-routing:         on

fast-route-download:                   off

fast-interface-lookup:                 on

routing-over-vlags:                    off

source-mac-miss:                       copy-to-cpu

igmp-snoop:                            use-l3

vle-tracking-timeout:                  3

pfc-buffer-limit:                      40%

cosq-weight-auto:                      off

port-cos-drop-stats-interval(s):       disable

lossless-mode:                         off

snoop-query-stagger:                   no-stagger-queries

host-refresh:                          off

proxy-conn-retry:                      on

proxy-conn-max-retry:                  3

proxy-conn-retry-interval:             500

manage-l2-uuc-drop:                    on

optimize-rxlos:                        off

xcvr-link-debug:                       disable

fastpath-bfd:                          off

linkscan-interval:                     150000

linkscan-mode:                         software

single-pass-l2-known-multicast:        off

single-pass-flood:                     off

single-pass-riot:                      off

xcvr-oir-debug-port:                   none

cos-8-and-9-queue:                     off

batch-move-mac-hw-group-for-vlan-only: off