fabric-node-show

This command is used to display information about a node from a fabric.

Syntax   fabric-node-show

id id-number

Specifies the identifier assigned to the node.

location-id location-id-number

Specifies the location ID assigned to the fabric node.

serial serial-string

Specifies the serial string for the fabric node

name fabric-node-name

Specifies the name of the fabric node to display information.

fab-name fab-name

Specifies the name of the fabric node.

fab-id

Specifies the fabric identifier.

cluster-id

Specifies the cluster identifier.

local-mac mac-address

Specifies the local MAC address of the fabric.

fabric-network in-band|mgmt|vmgmt

Specifies the fabric network type.

control-network in-band|mgmt||vmgmt

Specifies the interface to send control plane communications.

mgmt-ip ip-address

Specifies the IP address for the management NIC.

mgmt-netmask netmask

The netmask for the IP address.

mgmt-ip2 ip-address

Specifies the second IP address for the management NIC.

mgmt-netmask2 netmask

Specifies the netmask for the second IP address.

mgmt-assignment2 none|static|dhcp|dhcpv6|autov6

Specifies the type of IP address assignment.

mgmt-linklocal ip-address

Specifies the IPv6 address for the link local address.

mgmt-ipv6-unnumbered|mgmt-no-ipv6-unnumbered 

Specifies the IPv6 address is LinkLocal only.

mgmt-assignment-linklocal none|static|dhcp|dhcpv6|autov6

Specifies the type of link local IP address assignment.

mgmt-mac mac-address

Specifies the MAC address for the management interface.

mgmt-vnet vnet-name

Specifies the management vNET.

mgmt-public-vlan 0..4095 

Specifies the public VLAN ID.

mgmt-secondary-macs secondary-macs-string

Specifies the secondary MAC address of the management interface.

mgmt-if-nat-realm internal|external         

Specifies the NAT interface realm.

mgmt-vrf vrf name|default

Name of the VRF.

mgmt-sec-addresses sec-addresses-number

Number of IP and IPv6 addresses configured on this interface.

mgmt-wake-on-lan|mgmt-no-wake-on-lan

Specifies the wake on LAN.

vmgmt-ip ip-address

Specifies the IP address for the in-band interface to the switch control plane.

vmgmt-netmask netmask

Specifies the netmask for the in-band interface to the switch control plane.

vmgmt-ip2 ip-address

Specifies the second IP address for the in-band interface to the switch control plane.

vmgmt-netmask2 netmask

Specifies the second netmask for the in-band interface to the switch control plane.

vmgmt-assignment2 none|static|dhcp|dhcpv6|autov6

The type of IP address assignment.

vmgmt-linklocal ip-address 

IPv6 Link Local address.

vmgmt-ipv6-unnumbered|vmgmt-no-ipv6-unnumbered

Specifies the IPv6 address is LinkLocal only.

vmgmt-assignment-linklocal none|static|dhcp|dhcpv6|autov6

Specifies the type of IPv6 LinkLocal address assignment.

vmgmt-mac mac-address

Specifies the MAC address for the in-band interface to the switch control plane.

vmgmt-vnet vnet-name

Specifies the inband vNET name.

vmgmt-vlan 0..4095

Specifies the inband VLAN ID.

vmgmt-secondary-macs secondary-macs-string

The secondary MAC addresses.

vmgmt-vrf vrf name|default

Name of the VRF.

vmgmt-sec-addresses sec-addresses-number

Number of IP and IPv6 addresses configured on this interface.

vmgmt-wake-on-lan|vmgmt-no-wake-on-lan

Specifies the wake on LAN.

in-band-ip ip-address

Specifies the IP address for the in-band interface to the switch control plane.

in-band-netmask netmask

Specifies the netmask for the in-band interface to the switch control plane.

in-band-ip2 ip-address

Specifies the second IP address for the in-band interface to the switch control plane.

in-band-netmask2 netmask

Specifies the second netmask for the in-band interface to the switch control plane.

in-band-assignment2 none|static|dhcp|dhcpv6|autov6

The type of IP address assignment.

in-band-linklocal ip-address

The IPv6 LinkLocal address.

in-band-assignment-linklocal none|static|dhcp|dhcpv6|autov6

The type of IPv6 LinkLocal address assignment.

in-band-mac mac-address

Specifies the MAC address for the in-band interface to the switch control plane.

in-band-vnet vnet-name

Specifies the inband vNET name.

in-band-bd bridge-domain name

The interface Bridge Domain.

in-band-vlan 0..4095

Specifies the inband VLAN ID.

in-band-vlan-type public|private

Specifies the type of inband VLAN as public or private.

in-band-public-vlan 0..4095

Specifies the inband public VLAN ID.

in-band-secondary-macs secondary-macs-string

Specifies the secondary MAC address of the in-band interface

in-band-if-nat-realm internal|external

The NAT interface realm.

in-band-vrf vrf name|default

Name of the inband VRF.

in-band-sec-addresses sec-addresses-number

Number of IP and IPv6 addresses configured on this interface.

in-band-wake-on-lan|in-band-no-wake-on-lan

The inband wake on LAN.

fab-tid fab-tid-number

Specifies the fabric identifier.

cluster-tid cluster-tid-number

Specifies the cluster identifier.

out-port out-port-number

Specifies the port number where the switch multicasts the fabric discovery messages to other Pluribus Networks switch.

version version-string

Specifies the current ONVL version.

state offline|online|in-band-only-online|mgmt-only-online|vmgmt-only-online|offline(evicted)|online(joined)|eula-required|setup-required|fabric-required|fresh-install

Specifies the state of the fabric.

firmware_upgrade not-required|required|reboot-required

Specifies if a firmware upgrade is required.

device-state ok|error|simulator

Specifies the state of the switch.

ports ports-number

Specifies the port list used by the fabric.

keepalive-timeout high resolution time: #ns

Specifies the keepalive timeout in nanoseconds.

rollforward-failed true|false

Specifies the roll-forward status of the node.

Defaults   None

Access   CLI

History   

Version 1.2

Command introduced.

Version 2.3.2

The parameters cluster-id, cluster-tid, mgmt-assignment, mgmt-vm-nic-type, mgmt-nic, mgmt-vxlan, mgmt-if, mgmt-alias-on, mgmt-vm-nic-type, mgmt-exclusive, mgmt-nic-enable, mgmt-nic-state and corresponding in-band parameters deprecated.

Version 2.4.1

The parameters mgmt-vnet, mgmt-public-vlan, in-band-vnet, in-band-vlan-type and in-band-public-vlan added.

Version 5.1.1

The parameter keepalive-timeout added.

Version 7.0.0

The parameter rollforward-failed added.


Usage   The fabric consists of one or more switches sharing an administrative domain. The fabric presents the abstraction of a big logical switch with a single point of management, hiding the complexity of the underlying collection of switch hardware and inter-switch links. Use this command to display node information.

Examples  To display a list of fabrics visible from the local switch, use the following command:

CLI (network-admin@switch) > fabric-node-show format all layout vertical

id:                           201326960

location-id:                  3

serial:                       1434AT9000331

name:                         leo-ext-33

fab-name:                     leo-ext-31

fab-id:                       c00019c:61f3d676

local-mac:                    66:0e:94:70:f2:7a

fabric-network:               mgmt

control-network:              mgmt

mgmt-ip:                      10.13.44.53/23

mgmt-assignment2:             none

mgmt-ipv6-unnumbered:         no

mgmt-assignment-linklocal:    none

mgmt-mac:                     64:0e:94:c0:03:af

mgmt-if-nat-realm:            internal

mgmt-wake-on-lan:             no

vmgmt-assignment2:            none

vmgmt-ipv6-unnumbered:        no

vmgmt-assignment-linklocal:   none

vmgmt-wake-on-lan:            no

in-band-ip:                   192.168.25.33/24

in-band-assignment2:          none

in-band-assignment-linklocal: none

in-band-mac:                  66:0e:94:70:f2:7a

in-band-vlan:                 1

in-band-vlan-type:            public

in-band-if-nat-realm:         internal

in-band-wake-on-lan:          no

fab-tid:                      186

version:                      7.0.0-7000019025

state:                        online

firmware-upgrade:             not-required

device-state:                 ok

ports:                        72

rollforward-failed:           false

north
    keyboard_arrow_up
    keyboard_arrow_down
    description
    print
    feedback
    support
    business
    rss_feed
    south