System Log Messages


Version 7.0.2-7000219597


Identifier

Message

Code

Description

Severity

system_drop

lost [drops]d [msgs]s

10002

Unable to deliver system log(s) to nvlogd so system logs dropped.

Warn

update_find_server_failed

Failed to contact update server.

11006

Failed to find update server.

Warn

update_wrong_redirect

Unexpected redirect url(s) from update server.

11007

Got an unexpected redirect from HTTP update server lookup.

Warn

nvOSd_start

nvOSd start: version=version(s) changeset=changeset(s) branch=branch(s)

11008

nvOSd startup

Note

pkt_alloc_failed

feature(s) failed to allocate a send buffer.

11009

Failed to allocate a packet for sending from the CPU

Warn

syscall_failed_Critical

feature(s): syscall(s) failed: [error]m

11012

A system call failed.

Critical

resstart_nvOSd

Restarting exe(s)

11013

Restarting nvOSd.

Note

restart_nvOSd_failed

Failed to restart exe(s): [error]m

11014

Failed to restart nvOSd

Critical

nvOSd_init_failed

nvOSd failed to start: feature(s): [error]m

11015

nvOSd was unable to start.

Critical

loop_detected

LOOP: mac [mac]M [net]N on switch [old_switch]n port [old_port]d ([old_ip]I), also on switch [new_switch]n port [new_port]d ([new_ip]I) [caller]s

11016

Detected an L2 loop.

Note

mac_moved

MOVING MAC=[mac]M, vnet=[vnet]s vlan [vlan]d from switch [old_switch]n [old_port]d ([old_ip]I) to switch [new_switch]n [new_port]d [new_ip]I [caller]s

11017

MAC moved from one port to another.

Note

simulator_mode

Failed to init switch hardware.

11018

Simulator mode entered but not from command line.

Critical

fabric_joined

Joined fabric [fabname]s

11019

Switch joined a fabric.

Note

fabric_unjoined

Unjoined fabric [fabname]s

11020

Switch un-joined the fabric.

Note

config_imported

Imported configuration from [file]s

11021

Imported a new configuration.

Note

stp_switch_enable_failed

STP failed to initialize for switch hardware.

11028

STP initialization for underlying hardware switch failed.

Critical

stp_default_spanning_tree_failed

STP Failed to Create Default Spanning Tree: vlan=[vlan]d

11029

Unable to create the Spanning Tree for default VLAN.

Critical

stp_flow

STP Failed to install flow(s) for BPDU reception: [flow]s

11030

Unable to install STP flow(s) for the reception of STP packets.

Critical

stp_worker_thread_failed

STP failed to create worker thread: vlan=[vlan]d

11031

STP was unable to create worker thread for Spanning Tree.

Critical

stp_config_failed

Loading and application STP configuration failed.

11041

The loading and application of STP configuration failed.

Warn

stp_switch_port_state

STP Port State Failure: port=[port]d vlan=[vlan]d

11045

Unable to set the port state for the port on the VLAN.

Critical

stp_trunk_port_state

STP Set Port State: port=[port]d vlan=[vlan]d trunk=[trunk]d

11046

Invalid trunk in use by the spanning tree

Warn

mcast_switch_init

igmp/mld snooping unable to initialize switch hardware for groups

11047

IGMP/MLD was unable to initialize switch hardware for the group.

Critical

igmp_flow_add

IGMP snooping unable to add flow: flow=[flow]s

11048

IGMP was unable to add a flow for IGMP packet processing.

Warn

igmp_flow_remove

IGMP snooping not able to remove flow: flow=[flow]s

11049

IGMP snooping unable to remove flow for IGMP processing.

Warn

igmp_query_start

IGMP was not able to start query state machine.

11050

IGMP snooping unable to start query state machine.

Warn

igmp_query_stop

IGMP was not unable to stop query state machine.

11051

IGMP snooping unable to stop query state machine.

Warn

mcast_switch_fini

IGMP/mld snooping unable to halt switch hardware for groups.

11052

IGMP/MLD snooping unable to halt switch hardware for groups.


Warn

igmp_static_load

IGMP snooping unable to load static IGMP group.

11053

IGMP snooping unable to load static IGMP group.

Warn

igmp_static_source_load

IGMP snooping unable to load static IGMP source list.

11054

IGMP snooping unable to load static IGMP source list.

Warn

igmp_flooding

IGMP flooding not enabled.

11055

IGMP flooding not enabled.

Warn

mcast_group_add_failed

IGMP/MLD Group Add Failed: vlan=[vlan]d group=[group]s

11071

mcast snooping failed to add a group to switch hardware

Warn

mcast_group_remove_failed

IGMP/MLD Group Remove Failed: vlan=[vlan]d group=[group]s

11072

mcast snooping failed to remove a group from switch hardware

Warn

software_upgrade_initiated

nvOS software upgrade initiated for [verinfo]s

11073

Software upgrade initiated; downloading and installing new packages.

Note

software_upgrade_complete

System and nvOS software upgrade complete: [verinfo]s



11074

System and nvOS software upgrade complete.

Note

software_upgrade_failed

nvOS software upgrade failed: [err]s

11075

software upgrade failed.

Warn

system_reboot

System reboot initiated by nvOSd

11076

System reboot initiated by nvOSd.

Note

system_reboot_failed

System reboot initiated by nvOSd failed.

11077

System reboot initiated by nvOSd failed.

Warn

lldp_agent_create_thread_failed

LLDP Agent Thread Create Failed: mac=[mac]s group=[group]s error=[error]d

11079

Creation of threads for LLDP Agent failed.

Warn

lldp_flow_add_failed

LLDP Flow Add Failed: flow=[flow]s

11080

Adding flow for LLDP packet reception failed.

Warn

lldp_flow_remove_failed

LLDP Flow Remove Failed: flow=[flow]s

11081

Removing flow for LLDP packet reception failed.

Warn

evb_platform_not_supported

EVB is not supported on this platform: port=[port]d

11089

EVB is not supported on this platform.

Warn

evb_ecp_not_enabled

EVB ECP is Not Enabled: port

11090

Received EVB TLV with ECP not enabled.

Warn

evb_flow_remove_failed

EVB Flow Remove Failed: flowstr=[flowstr]s

11095

Unable to remove specified EVB flow.

Warn

lldp_agent_create_failure

LLDP Agent Create Failed: agent=[agent]s

11111

Failed to create LLDP agent for one of three agent addresses.

Warn

stats_log_open_failed

file=[file]s: stats log file open failed

11140

Log file open failed

Warn

container_rebuild_start

container=[container]s rebuild is started

11141

Container rebuild is started

Note

container_rebuild_end

container=[container]s rebuild is completed

11142

Container rebuild is completed

Note

all_container_rebuild

all containers are rebuilt

11143

All containers are rebuilt

Warn

loop_broken

LOOP Broken: port=[port]d vlan=[vlan]d mac=[mac]s ip=[ip]s

11180

A loop was broken on a port or VLAN for a MAC or IP address

Warn

loop_stp

LOOP STP: port=[port]d vlan=[vlan]d mac=[mac]s ip=[ip]s

11181

A loop was detected that STP should have prevented.

Warn

update_auto_upgrade

PN Cloud initiated software upgrade

11210

The update server initiated an upgrade for nvOS.

Note

update_error

Error message from PN Clould: [msg]s

11211

The update server sent an error message.

Warn

ps_initial_status

Power supply [psu]d initial status [status]s

11302

Power supply initial status

Warn

fan_initial_status

Fan [fan]d initial status [status]s

11303

Fan initial status.

Warn

ps_status_change

Power supply [psu]d changed from [init_status]s to [new_status]s

11304

Power supply state change.

Warn

fan_status_change

Fan [fan]d changed from [init_status]s to [new_status]s

11305

Fan status change

Warn

fabric_node_duplicate_ip

Fabric node has the same ip=[ip]I as the local node, cannot send to it

11319

Fabric node has the same IP as the local node, cannot send to it.

Warn

upgrade_error

software upgrade error: [name]s: [func]s - [err]s

11324

Software Upgrade errors

Warn

upgrade_informational

software upgrade Note: [name]s: [func]s - [info]s

11325

Software Upgrade informational messages

Note

upgrade_reboot

System reboot initiated by upgrade agent

11326

System reboot initiated by software upgrade

Note

upgrade_reboot_failed

System reboot initiated by upgrade agent failed

11327

System reboot initiated by software upgrade failed

Warn

openstack_nat_failed

Failed to setup NAT on the OpenStack controller [name]s

11328

Failed to configure NAT for OpenStack

Warn

mac_tunnel_to_port

MOVING MAC=[mac]M, vnet=[vnet]s vlan=[vlan]d from tunnel=[tunnel]s ip=[old_ip]I to port=[port]d ip=[new_ip]I [caller]s

11329

MAC moved from a tunnel to a port

Warn

mac_port_to_switch

MOVING MAC=[mac]M, vlan=[vlan]d from switch=[old_sw]s port=[old_port]d ip=[old_ip]I to switch=[new_sw]s port=[new_port]d ip=[new_ip]I [caller]s

11330

MAC moved from a port to another switch

Note

mld_flow_add

mld snooping unable to add flow: flow=[flow]s

11341

MLD was unable to add a flow for MLD packet processing

Warn

mld_flow_remove

mld snooping not able to remove flow: flow=[flow]s


11342

MLD snooping unable to remove flow for MLD processing

Warn

mld_query_start

mld snooping unable to start query state machine

11343

MLD snooping was not able to start query state machine.

Warn

mld_query_stop

mld snooping unable to stop query state machine

11344

MLD was not able to stop the query state machine.

Warn

mld_static_load

mld snooping unable to load static mld group

11345

MLD snooping unable to load static MLD group.

Warn

mld_static_source_load

mld snooping unable to load static mld group source list

11346

MLD snooping unable to load static MLD group source list.

Warn

xact_node_ignored

Ignoring offline or out of sync cluster node name=[name]s for transaction tid=[tid]d

11366

Ignored offline or out of sync cluster node for transaction

Warn

xact_recover

Transactions out-of-sync detected, rolled forward from old=[old]d to new=[new]d via node=[node]s

11367

Auto-recovered from transactions being out of sync.

Warn

xact_recover_failed

Transaction auto-recover failed: [msg]s

11368

Auto-recover attempted but failed

Warn

ip_moved

Moving ip=[ip]I from old-mac=[old_mac]M to new-mac=[new_mac]M

11369

IP address moved from one MAC to another MAC

Note

software_license_expiring

software license(s) expiring soon code=[code]s expires_on=[expires_on]s

11370

Software license(s) expiring

Warn

software_license_expired

software license(s) have expired code=[code]s expired_on=[expires_on]s

11371

Software license(s) have expired

Warn

l2_check_missing

Add missing l2 entry to hardware: mac=[mac]M [net]N vxlan=[vxlan]d port=[port]d tunnel=[tunnel_name]s result=[result]s

11376

Add layer 2 entry that was missing in hardware

Warn

l2_check_bad_port

Fix l2 entry in hardware with incorrect port: mac=[mac]M [net]N vxlan=[vxlan]d old_port=[old_port]d new_port=[new_port]d result=[result]s

11377

Fix layer 2 entry in hardware with incorrect port

Warn

l2_check_orphaned

Remove orphaned l2 entry from hardware: mac=[mac]M [net]N vxlan=[vxlan]d port=[port]d tunnel=[tunnel]s result=[result]s

11378

Remove orphaned layer 2 entry in hardware (not in software table)

Warn

mac_move_denied

MOVE DENIED mac=[mac]M [net]N from switch=[sw]n port=[port]d to deny-switch=[deny_sw]n deny-port=[deny_port]d reason=[reason]s

11379

MAC moved not allowed

Note

host_port_loop_detected

Looping traffic detected on switch=[sw]n local-host-port=[port]d [net]N. Traffic on this port/network will be ignored until loop resolved

11380

Loop detected on host port

Warn

host_port_loop_resolved

Traffic has stopped looping on host-port=[port]d [net]N

11381

Loop on host port is no longer happening

Note

owner_mac_moved

caller=[caller]s owner=[owner]n mac=[mac]M vnet=[vnet]s vlan=[vlan]d moved from old-local-port=[old_port]d to new-local-port=[new_port]d

11382

Other switch's MAC moved from one local port to another

Note

mstp_set_port_state_failed

STP Port State Failure: port=[port]d instance=[instance]d

11384

Unable to set the STP state for the port on the MST instance

Critical

mac_port_to_tunnel

MOVING MAC=[mac]M, vnet=[vnet]s vlan=[vlan]d from port=[port]d ip=[old_ip]I to tunnel=[tunnel]s ip=[new_ip]I [caller]s

11385

MAC moved from a port to a tunnel

Note

cluster_vlag_l2_update_failed

Updating mac=[mac]M vnet=[vnet]s vlan=[vlan]d from peer update to vlag port port=[port]d failed, cluster may be out-of-sync: reason=[reason]

11386

Updating mac to vlag port in response to peer status update failed, cluster L2 may be out of sync

Warn

cluster_tunnel_l2_update_failed

Updating mac=[mac]M vxlan=[vxlan]d tunnel=[tunnel]s from peer update failed, cluster may be out-of-sync: reason=[reason]s

11387

Updating tunnel mac in response to peer status update failed, cluster L2 may be out of sync

Warn

cluster_comm_l2_update_failed

Updating mac=[mac]M vnet=[vnet]s vlan=[vlan]d from peer update to cluster port port=[port]d failed, cluster may be out-of-sync: reason=[reason]s

11388

Updating mac to cluster link in response to peer status update failed, cluster L2 may be out of sync

Warn

l2_check_bad_tunnel

Fix l2 entry in hardware with incorrect tunnel: mac=[mac]M [net]N vxlan=[vxlan]d old_tunnel=[old_tunnel]s new_tunnel=[new_tunnel]s result=[result]s

11389

Fix layer 2 entry in hardware with incorrect tunnel

Note

l2_check_mismatch_vport

Mismatched vport entry: mac=[mac]M [net]N vxlan=[vxlan]d hw_vlan=[hw_vlan]d hw_vxlan=[hw_vxlan]d result=[result]s

11390

Mismatched vport entry

Note

l2_check_mark_port_mac

Marked vport as port-mac: mac=[mac]M [net]N vxlan=[vxlan]d

11391

Marked owned local vport as port-mac

Warn

l2_check_delete_port_mac

Delete invalid port-mac vport: mac=[mac]M [net]N vxlan=[vxlan]d

11392

Delete port-mac that should not be in vport table

Warn

hostid_collision_detected

Our hostid is being used by another node [node_name]s

11393

Received keep-alive from another node having same hostid

Critical

mirror_to_cpu_configured

Mirror to CPU configured on vFlow [vflow_name]s

11395

Mirror to CPU configured

Note

low_disk_space

Disk Space Usage has exceeded threshold of 70 percent

11396

Disk space usage exceeds 70 percent

Warn

stp_vnet_port_recv

received STP BPDU on vnet port: port=[port]d

11397

Received an STP BPDU on a vnet port

Warn

igmp_disabled

Disabling IGMP on network: [net]N

11398

Disabling IGMP on network

Note

igmp_enabled

Enabling IGMP on network: [net]N

11399

Enabling IGMP on network

Note

l2_check_hw_invalid

Remove invalid l2 entry from hardware: mac=[mac]M [net]N vxlan=[vxlan]d port=[port]d tunnel=[tunnel]s result=[result]s

11400

Remove invalid layer 2 entry in hardware (incorrect HW entry)

Warn

congestion_on_port

Congestion detected on port=[port]d

11401

Congestion detected on port. Positive icongdrop/ocongdrop

Critical

congestion_relieved_on_port

Congestion relieved on port=[port]d

11402

Congestion relieved on port.

Critical

fabric_node_status

[node_name]s: Node status changed to [status]s

11403

Fabric node state change

Note

mld_disabled

Disabling MLD on vlan: vlan=[vlan]d

11404

Disabling MLD on vlan

Note

mld_enabled

Enabling MLD on vlan: vlan=[vlan]d

11405

Enabling MLD on vlan

Note

vlan_public_id_mismatch

vnet=[vnet]s vlan=[vlan]d public-id mismatch while cluster offline

11406

While cluster was offline vlan public-id mismatch happened

Error

vlan_port_node_ignored

Ignoring offline cluster node name=[name]s while assigning public vlan to vnet=[vnet]s vlan=[vlan]d

11407

Ignored offline cluster for private vlan port assignment

Warn

vlan_public_id_fail

failed to set public-vlan for vnet=[vnet]s vlan=[vlan]d msg=[msg]s

11408

Failed to set public vlan id while handling cluster status update

Error

bad_xcvr_detected

unable to access I2C bus; possible bad transceiver

11409

Unable to access I2C bus; possibly a bad transceiver is inserted

Error

tacacs_server_error

server=[server]s TACACS+ authorization disabled due to repeated server errors

11414

Repeated TACACS+ server errors. TACACS+ authorization disabled

Critical

tacacs_server_ok

server=[server]s TACACS+ authorization enabled due to server errors resolved

11415

TACACS+ server has recovered from errors. TACACS+ Authorization enabled.

Note

dhcp_untrusted_msg

DHCP server message received from untrusted port=[port]d server-ip=[ip]I

11416

Received DHCP server message from an untrusted port.

Warn

fabric_guard_loop_detect

Fabric-guard detected a loop on port [port]d. Port blocked.

11422

Fabric-guard detected loop

Note

replace_offline_node

loc-id=[loc_id]d: node=[name]s node-id=[node_id]d replacing old-node=[old_name]s old-node-id=[old_node_id]d

11423

New node replacing offline node with the same location id.

Note

loc_id_conflict

loc-id=[loc_id]d owned by node=[name]s node-id=[node_id]d, ignore message from conflict-node=[old_name]s conflict-node-id=[old_node_id]d

11424

Two nodes with the same loc-id is not allowed, ignoring latest

Warn

ntp_server_sync

NTP server is unresolvable/unreachable

11431

NTP server not resolvable/reachable

Critical

xact_rollforward_ignore_error

Transactions rollforward tid=[tid]d cmd=[cmd]s failed result=[result]R, ignoring error

11432

xact rollforward failure overridden by user

Warn

xact_rollback_ignore_error

Transactions rollback tid=[tid]d cmd=[cmd]s failed result=[result]R, ignoring error

11433

xact rollback failure overridden by user

Warn

nxu_module_fw_upgrade

Installed version: [inst]s; available version [avail]s

11434

One or more Lutera xcvrs require module firmware upgrade

Warn

nxu_chipset_fw_upgrade

Installed version: [inst]s; available version [avail]s

11435

One or more Lutera xcvrs require chipset firmware upgrade

Warn

sensor_unavailable

sensor [name]s cannot be accessed

11436

Sensor cannot be read by BMC

Warn

ipv6_raguard_ra_port_drop

Dropping RA from port=[port]d. [msg]s

11504

Drop RA packet from port according to RA Guard Policy

Warn

ipv6_raguard_ra_port_drop

Dropping RA from vlan=[vlan]d. [msg]s

11505

Drop RA packet from vlan according to RA Guard Policy

Warn

disk_health_below_RMA

The disk health level [current]d is significantly below recommended level [rma]d, please notify Pluribus TAC immediately

11514

The disk health is below the minimum required to work needs to be RMAed


Critical

disk_health_below_minimum

The disk health level [current]d is below recommended level [rma]d, please notify Pluribus TAC

11515

The disk health is below the minimum required to work

Critical

disk_health_filesystem_readonly


The filesystem [part]s is in Read Only mode, please notify Pluribus TAC immediately

11516

The disk partition is mounted read-only

Critical

low_disk_space_ninety

Disk Space Usage has exceeded threshold of 90 percent

11517

Disk space usage exceeds 90 percent

Warn

normal_space

Disk Space Usage is normal below 70 percent

11518

Disk space usage is normal

Warn

SI_setting_update

Changed SI setting for port(s) [pmap]s to [cbl_type]s

11519

User has set explicit port cable type

Warn

unsupported_platform


Support for this hardware was deprecated starting with nvOS [eos]s and later.Please review the Release Notes for this and previous releases to find the list of supported hardware, and revert back to an earlier supported release

11520

Not supported

Warn

fabric_password_update

[node_name]s: [msg]s

11522

Password reset or changed

Note

excess_mac_move

Excess MAC moves detected for mac=[mac]M, vnet=[vnet]s vlan=[vlan]d vxlan=[vxlan]d

11523

Excess MAC moves detected

Note

excess_ip_move

Excess IP moves detected for ip=[ip]I vnet=[vnet]s vlan=[vlan]d vxlan=[vxlan]d

11524

Excess IP moves detected

Note

clear_excess_mac_move

Excess MAC move condition cleared for mac=[mac]M, vnet=[vnet]s vlan=[vlan]d vxlan=[vxlan]d

11525

Excess MAC move condition cleared

Note

clear_excess_ip_move

Excess IP move condition cleared for ip=[ip]I vnet=[vnet]s vlan=[vlan]d vxlan=[vxlan]d

11526

Excess IP move condition cleared

Note

port_oir_error_enter

Port=[port]d enter xcvr oir error state

11527

Port enter xcvr oir error state

Warn

port_oir_error_exit

Port=[port]d exit xcvr oir error state

11528

Port exit xcvr oir error state

Warn

maintenance_enabled

System is in Maintenance mode

11529

System state is maintenance-enabled

Warn

maintenance_disabled

System is in Operational mode

11530

System state is operational (maintenance-disabled)

Note

current_date_and_time

Current date and time: [timestr]s

11539

Log the previous date and time and origin

Info

new_date_and_time

New date and time: [timestr]s

11540

Log the new date and time and origin

Info

rx_port_bw_th_exceed

Ingress threshold at port exceeded port bw threshold

11549

Ingress threshold at port exceeded port bw threshold

Warn 

rx_port_bw_th_not_exceed

Ingress port bandwidth threshold no longer exceeding at port=[port]d

11550

Ingress threshold at port not exceeding port bw threshold

Warn

tx_port_bw_th_exceed

Egress port bandwidth threshold exceeded at port=[port]d

11551

Egress threshold at port exceeded port bw threshold

Warn

tx_port_bw_th_not_exceed

Egress port bandwidth threshold no longer exceeding at port=[port]d

11552

Egress threshold at port not exceeding port bw threshold

Warn

uplink_oversubscription

uplink group oversubscription due to [trigger]s.

11553

Uplink oversubscription is observed.

Warn

syslog_send_failed

Failed to send log message to syslog: server=[server]s \"err=[err]m\"

20000

sendto failed. This probably means some sort of resource exhaustion because it's a udp socket we're sending on

Error

syslog_hostname_lookup_failed

Failed to resolve hostname=[host]s for syslog server=[server]s err=\"[err]m\"

20001

Switch may have DNS problems, or admin has configured a bogus hostname for syslog server

Error

system_repeats

Last [msgs]d message(s) repeated [times]d time(s)

20002

Compress repeated messages

Note

reset_counters

system log counters reset timestamp [timestamp]s

20005

Reset system log counters.

Note

syslog_tls_server_down

tcp-tls connection to syslog server=[server]s down. Logs are not getting exported

20006

Connection to syslog export TCP/TLS server is down. syslog export to external server is not happening.

Error

syslog_tls_server_restored

tcp-tls connection to syslog server=[server]s restored. Log export is operational

20007

Connection to syslog export TCP/TLS server is restored.

Note

syslog_tls_server_dropped

syslog export log messages to syslog server=[server]s getting dropped

20008

Syslog export message(s) to TCP/TLS server dropped.

Error

syslog_tls_server_delayed

syslog export log messages to syslog server=[server]s getting delayed

20009

Syslog export message(s) to TCP/TLS server delayed.

Error

generic_platform_audit

platform audit message: [msg]s

20010

Platform audit message

Note

container_log

container log message: [msg]s

20011

Logs from the containers

Note

os_logs

OS audit log message: [msg]s

20012

Logs from the Operating system auditing

Note

mon_start

=== nvOS_mon start ===

30000

nvOS_mon startup

Note

mon_exit

Exiting because reason(s)

30001

Monitor exiting for some reason.

Warn

mon_reboot

system reboot

30004

nvOS_mon is rebooting the system

Note

mon_restart_nvOSd

Monitor restarting nvOSd

30005

Restarting nvOSd

Note

mon_failure_detected

Monitor detected failure [failure]s

30006

Monitor detected a failure.

Warn

mon_reset

Reset nvOSd config

30007

nvOS_mon is resetting nvOSd's configuration.

Note

mon_grub_gen

Regenerating grub configuration for new boot environment.

30008

nvOS_mon is regenerating grub.

Note

mon_restart_tomcat

Monitor restarting tomcat.

30009

Restarting tomcat.

Note

mon_cpu_usage_high

High cpu usage detected.

30010

High CPU usage detected.

Note

mon_memory_usage_high

High memory usage detected

30011

high memory usage detected.

Note

mon_disable_ports

nvOSd cannot be revived; disabling ports to prevent headless switching.

30012

Monitor failed to restart nvOSd; disabling ports to prevent headless switching.

Critical

mon_auth_failed

User authorization failed for user [name]s, pid [pid]d, ip [ip]I

30013

User authorization failed.

Note

mon_keepalive_hung

nvOS_mon is possibly stuck ! [action]s

30014

nvOS_mon keepalive_checker thread is possibly hung.

Critical

mon_autoreboot_cancel

[reason]s; the system will not be rebooted.

30015

System will not be rebooted; auto-reboot is disabled or software-upgrade is in progress.

Critical

mon_autoreboot_failed

System failed to auto-reboot: [reason]s

30016

auto-reboot failed

Critical

mon_cpu_usage_higher_than_seventy

CPU usage higher than 70 percent detected

30017

CPU usage higher than 70 percent detected

Warn

mon_memory_usage_higher_than_seventy

Memory usage higher than 70 percent detected

30018

Memory usage higher than 70 percent detected

Warn

mon_memory_usage_lower_than_sixtyfive

Memory usage is normal, lower than 65([mem].2f) percent detected

30019

Memory usage is normal, lower than 65 (%[mem].2f)  percent detected

Note

mon_memory_usage_higher_than_eighty

Memory usage higher than 80 percent detected

30020

Memory usage higher than 80 percent detected

Warn

mon_memory_usage_higher_than_ninety

Memory usage higher than 90 percent detected

30021

Memory usage higher than 90 percent detected

Warn

fanmon_fan_status

Controller [controller]d fan [fan]d speed [rpm]d RPM

31000

Initial status of a fan

Note

fanmon_fan_missing

Controller [controller]d fan [fan]d is missing

31001

Fan is missing

Warn

fanmon_fan_status_max

Controller [controller]d fan [fan]d speed is max

31002

Fan is set to maximum speed.

Note

fanmon_fan_fault

Controller [controller]d fan [fan]d fault: [fault]s

31003

Fan fault detected

Warn

fanmon_fan_fault_compensate

One fan failed; setting all other fans to max speed

31004

One fan faulted, so setting all other fans to max speed to compensate

Warn

fanmon_poweroff

Fan monitor powering down system: [reason]s

31005

Fan monitor powering down system due to faults or overtemp

Critical

smf_nvOSd_start

SMF Service starting nvOSd

31007

SMF starting nvOSd

Note

smf_nvOSd_stop

SMF Service stopping nvOSd

31008

SMF stopping nvOSd

Note

hw_route_prec0_detected

F64 count=[count]d hardware routes with invalid precedence detected

31011

Aquila hardware route with invalid precedence detected

Critical

fanmon_fan_info

Current temp [temp]d Current speed [rpm]d RPM

31015

Show current temperature and Fan Speed setting info

Note

hwmon_start

=== nvOSd_hwmon start ===

32000

nvOSd_hwmon startup

Note

hwmon_exit

exiting because [reason]s

32001

Hardware monitor exiting for some reason

Warn

hwmon_power_supply_fault

power supply [name]s fault

32002

Power supply has failed

Critical

hwmon_power_supply_ok

power supply [name]s has recovered from faulted state

32003

Power supply OK

Note

hwmon_fan_fault

fan [name]s fault

32004

Fan has failed

Critical

hwmon_fan_ok

fan [name]s has recovered from faulted state

32005

Fan ok

Note

hwmon_sensor_fault

temperature sensor [name]s fault

32006

Temperature sensor fault

Warn

hwmon_sensor_ok

temperature sensor [name]s has recovered from faulted state

32007

Temperature sensor ok

Note

hwmon_temp_warning

[name]s at [t1]dC, shutdown at [t2]dC

32008

High temperature warning

Warn

hwmon_temp_Critical

[name]s at [t1]dC, shutdown at [t2]dC

32009

High temperature Critical

Critical

hwmon_temp_shutdown

shutting down system: [name]s at [t1]dC

32010

High temperature system shutdown

Critical

hwmon_shutdown_failed

system high temperature shutdown failed

32011

High temperature system shutdown failed

Critical

hwmon_temp_ok

[name]s at [t1]dC, temperature ok

32012

Temperature OK

Note

hwmon_watt_sensor_fault

power sensor %[name]s fault

32013

Power sensor has failed

Critical

hwmon_watt_sensor_ok

power sensor %[name]s has recovered from faulted state

32014

Power sensor  OK

Note

north
    keyboard_arrow_up
    keyboard_arrow_down
    description
    print
    feedback
    support
    business
    rss_feed
    south