port-cable-type-show
The SerDes (serializer/deserializer) link in switch ports have several associated Signal Integrity (SI) parameters that help in shaping the output into a clean, and well-defined signal based on the transmission line characteristics of the signal traces. This output shaping is used to cancel-out factors such as reflection, and signal attenuation, and enables the receiver to get a clean, and well-defined signal. Collectively, these SI parameters are also known as pre-emphasis settings.
You can display the pre-emphasis (Signal Integrity) settings for specified ports by using this command.
Syntax port-cable-type-show
port port-list |
The list of ports to be displayed. |
type sys-default|optical|dac|acc-3m|acc-5m|dac-0-5m|dac-1-0m|dac-2-0m|dac-3-0m|dac-5-0m|dac-7-0m |
The cable type to be displayed. |
cable-sub-type default|ca-n|ca-l|ca-s |
The port cable assembly type from one of the options. Note that this optional parameter is applicable only for DAC cable types. Note: The cable sub type (N, L, or S) is a hardware specific parameter based on the material used by the cable manufacturer. Hence, you must consult the vendor specification to identify the cable assembly type before configuring this parameter. |
Defaults None
Access Network Administrator
History
Version 6.0.0 |
Command introduced. |
Usage Use this command to display pre-emphasis settings.
Examples To display the pre-emphasis settings on switch1, use the command:
CLI (network-admin@switch)1 > port-cable-type-show
switch port type cable-sub-type
------- ----- -------- --------------
switch1 none dac ca-s
switch1 none dac ca-l
switch1 none dac ca-n
switch1 1-125 dac default
switch1 none optical default