cluster-bringdown-modify
This command is used to modify cluster bring down settings.
Syntax cluster-bringdown-modify
Specify any of the following options: |
|
vlag-port-staggered-interval duration: #d#h#m#s |
Specifies the interval between vLAG ports bringdown. |
defer-node-1-ports port-list |
Specify the ports to be brought down after vLAG & l3 for cluster-node-1. |
defer-node-2-ports port-list |
Specify the ports to be brought down after vLAG & l3 for cluster-node-2. |
fast_port_down|no-fast_port_down |
Specifies faster, simultaneous port down during switch reboot. |
Defaults None
Access CLI
History
Version 6.1.1 |
Command introduced. |
Usage Use this command to modify cluster bring down settings.
Examples To modify cluster bring down settings, use the following command:
CLI (network-admin@switch) > cluster-bringdown-modify vlag-port-staggered-interval 3s