fabric-node-show
This command is used to display node information in a fabric.
Syntax fabric-node-show
id id-number |
The identifier assigned to the node. |
location-id location-id-number |
The location ID assigned to the fabric node. |
serial serial-string |
The serial string for the fabric node |
name fabric-node-name |
The name of the fabric node to display information. |
fab-name fab-name |
The name of the fabric node. |
fab-id |
The fabric identifier. |
cluster-id |
The cluster identifier. |
local-mac mac-address |
The local MAC address of the fabric. |
fabric-network in-band|mgmt|vmgmt |
The fabric network type. |
control-network in-band|mgmt||vmgmt |
The interface to send control plane communications. |
mgmt-ip ip-address |
The IP address for the management NIC. |
mgmt-netmask netmask |
The netmask for the IP address. |
mgmt-ip2 ip-address |
The second IP address for the management NIC. |
mgmt-netmask2 netmask |
The netmask for the second IP address. |
mgmt-assignment2 none|static|dhcp|dhcpv6|autov6 |
The type of IP address assignment. |
mgmt-linklocal ip-address |
The IPv6 address for the link local address. |
mgmt-ipv6-unnumbered|mgmt-no-ipv6-unnumbered |
The IPv6 address is LinkLocal only. |
mgmt-assignment-linklocal none|static|dhcp|dhcpv6|autov6 |
The type of link local IP address assignment. |
mgmt-mac mac-address |
The MAC address for the management interface. |
mgmt-vnet vnet-name |
The management vNET. |
mgmt-public-vlan 0..4095 |
The public VLAN ID. |
mgmt-secondary-macs secondary-macs-string |
The secondary MAC address of the management interface. |
mgmt-if-nat-realm internal|external |
The NAT interface realm. |
mgmt-vrf vrf name|default |
Name of the VRF. |
mgmt-sec-addresses sec-addresses-number |
Number of IP, and IPv6 addresses configured on this interface. |
mgmt-wake-on-lan|mgmt-no-wake-on-lan |
The wake on LAN. |
vmgmt-ip ip-address |
The IP address for the in-band interface to the switch control plane. |
vmgmt-netmask netmask |
The netmask for the in-band interface to the switch control plane. |
vmgmt-ip2 ip-address |
The second IP address for the in-band interface to the switch control plane. |
vmgmt-netmask2 netmask |
The second netmask for the in-band interface to the switch control plane. |
vmgmt-assignment2 none|static|dhcp|dhcpv6|autov6 |
The type of IP address assignment. |
vmgmt-linklocal ip-address |
IPv6 Link Local address. |
vmgmt-ipv6-unnumbered|vmgmt-no-ipv6-unnumbered |
The IPv6 address is LinkLocal only. |
vmgmt-assignment-linklocal none|static|dhcp|dhcpv6|autov6 |
The type of IPv6 LinkLocal address assignment. |
vmgmt-mac mac-address |
The MAC address for the in-band interface to the switch control plane. |
vmgmt-vnet vnet-name |
The inband vNET name. |
vmgmt-vlan 0..4095 |
The inband VLAN ID. |
vmgmt-secondary-macs secondary-macs-string |
The secondary MAC addresses. |
vmgmt-vrf vrf name|default |
Name of the VRF. |
vmgmt-sec-addresses sec-addresses-number |
Number of IP, and IPv6 addresses configured on this interface. |
vmgmt-wake-on-lan|vmgmt-no-wake-on-lan |
The wake on LAN. |
in-band-ip ip-address |
The IP address for the in-band interface to the switch control plane. |
in-band-netmask netmask |
The netmask for the in-band interface to the switch control plane. |
in-band-ip2 ip-address |
The second IP address for the in-band interface to the switch control plane. |
in-band-netmask2 netmask |
The second netmask for the in-band interface to the switch control plane. |
in-band-assignment2 none|static|dhcp|dhcpv6|autov6 |
The type of IP address assignment. |
in-band-linklocal ip-address |
The IPv6 LinkLocal address. |
in-band-assignment-linklocal none|static|dhcp|dhcpv6|autov6 |
The type of IPv6 LinkLocal address assignment. |
in-band-mac mac-address |
The MAC address for the in-band interface to the switch control plane. |
in-band-vnet vnet-name |
The inband vNET name. |
in-band-bd bridge-domain name |
The interface Bridge Domain. |
in-band-vlan 0..4095 |
The inband VLAN ID. |
in-band-vlan-type public|private |
The type of inband VLAN as public or private. |
in-band-public-vlan 0..4095 |
The inband public VLAN ID. |
in-band-secondary-macs secondary-macs-string |
The secondary MAC address of the in-band interface |
in-band-if-nat-realm internal|external |
The NAT interface realm. |
in-band-vrf vrf name|default |
Name of the inband VRF. |
in-band-sec-addresses sec-addresses-number |
Number of IP, and IPv6 addresses configured on this interface. |
in-band-wake-on-lan|in-band-no-wake-on-lan |
The inband wake on LAN. |
fab-tid fab-tid-number |
The fabric identifier. |
cluster-tid cluster-tid-number |
The cluster identifier. |
out-port out-port-number |
The port number where the switch multicasts the fabric discovery messages to other Pluribus Networks switch. |
version version-string |
The current ONVL version. |
state offline|online|in-band-only-online|mgmt-only-online|vmgmt-only-online|offline(evicted)|online(joined)|eula-required|setup-required|fabric-required|fresh-install |
The state of the fabric. |
firmware_upgrade not-required|required|reboot-required |
Specifies if a firmware upgrade is required. |
device-state ok|error|simulator |
The state of the switch. |
ports ports-number |
The port list used by the fabric. |
keepalive-timeout high resolution time: #ns |
The keepalive timeout in nanoseconds. |
rollforward-failed true|false |
The roll-forward status of the node. |
Defaults None
Access CLI
History
Version 1.2 |
Command introduced. |
Version 2.3.2 |
The parameters cluster-id, cluster-tid, mgmt-assignment, mgmt-vm-nic-type, mgmt-nic, mgmt-vxlan, mgmt-if, mgmt-alias-on, mgmt-vm-nic-type, mgmt-exclusive, mgmt-nic-enable, mgmt-nic-state, and corresponding in-band parameters deprecated. |
Version 2.4.1 |
The parameters mgmt-vnet, mgmt-public-vlan, in-band-vnet, in-band-vlan-type, and in-band-public-vlan added. |
Version 5.1.1 |
The parameter keepalive-timeout added. |
Version 7.0.0 |
The parameter rollforward-failed added. |
Usage The fabric consists of one or more switches sharing an administrative domain. The fabric presents the abstraction of a big logical switch with a single point of management, hiding the complexity of the underlying collection of switch hardware, and inter-switch links. Use this command to display node information.
Examples To display a list of fabrics visible from the local switch, use the following command:
CLI (network-admin@switch) > fabric-node-show
name fab-name mgmt-ip in-band-ip in-band-vlan-type fab-tid version state firmware-upgrade device-state
------ -------- -------------- ---------------- ----------------- ------- ---------------- ------ ---------------- ------------
switch fabric 10.13.44.53/23 192.168.25.33/24 public 5 6.0.0-6000016312 online not-required ok