system-settings-modify

This command allows you to modify system settings to optimize NetVisor performance.

Syntax   system-settings-modify

optimize-arps|no-optimize-arps

Enable or disable ARP optimization. This feature is ON by default. When ON, the NetVisor OS sends all ARP requests, and Gratuitous ARP requests to the local CPU of the corresponding switch, and responds to ARP requests on behalf of the intended ARP targets. This feature corresponds to an ARP-proxy function on the corresponding switch. It is assumed that ARP requests, and Gratuitous ARP requests are used by NetVisor OS to learn the MAC address to IPv4 address mapping, as well as Unknown Unicast, and Broadcast traffic when The parameters manage-unknown-unicast or manage-broadcast are ON. When OFF, the NetVisor learns, and bridges ARP requests on the switch ASIC instead of relying on the local CPU.

lldp|no-lldp

Enable or disable LLDP discovery.

policy-based-routing|no-policy-based-routing

Enable or disable policy-based routing.

optimize-nd|no-optimize-nd

Enable or disable Neighbor Discovery optimization. This feature is ON by default. When ON, NetVisor OS sends all Neighbor Solicitations, and Unsolicited Neighbor Advertisements to the local CPU of the corresponding switch, responds to Neighbor Solicitation requests on behalf of the intended ND targets themselves. This feature corresponds to an ND-proxy function on the corresponding switch. Neighbor Solicitations, and Unsolicited Neighbor Advertisements are used by NetVisor OS to learn the MAC address to IPv6 address mapping, as well as Unknown Unicast, and Broadcast traffic when tThe parameters manage-unknown-unicast or manage-broadcast are ON. When OFF, the NetVisor learns, and bridges Neighbor Solicitations on the switch ASIC instead of relying on NetVisor OS.

reactivate-mac|no-reactivate-mac

Enable or disable reactivation of aged out MAC entries. This feature is ON by default. When ON, if a vPort entry is looked up, and found as inactive, the corresponding l2-table entry is re-activated on the switch. When OFF, the traffic is flooded on the corresponding broadcast domain by theNetVisor OS. Please note that l2-table entries are refreshed on the Ethernet switch ASIC every time it is used, otherwise it is removed after a time of inactivity corresponding to configured aging period. Requires unknown-unicast to be enabled.

reactivate-vxlan-tunnel-mac|no-reactivate-vxlan-tunnel-mac

Enable or disable enable reactivation of MAC entries over VXLAN tunnels.

manage-unknown-unicast|no-manage-unknown-unicast

Enable or disable unknown unicast management. This feature is ON by default. NetVisor sends all unknown-unicast traffic to the local CPU of the corresponding switch. NetVisor learns the source of unknown-unicast packets, and floods the packets on the corresponding unknown-unicast domain. When OFF, all unknown-unicast traffic is flooded on the corresponding unknown-unicast domain by the switch instead of relying on NetVisor OS.

manage-broadcast|no-manage-broadcast

Enable or disable broadcast management. This feature is ON by default. NetVisor sends all broadcast traffic to the local CPU of the corresponding switch. NetVisor learns the source of broadcast packets, and floods the packets on the corresponding broadcast domain. When OFF, all unicast traffic is flooded on the corresponding broadcast domain by the switch instead of relying on NetVisor OS.

manage-wake-on-lan|no-manage-wake-on-lan        

Enable wake-on-lan management.

auto-trunk|no-auto-trunk

Enable or disable auto trunking.

auto-host-bundle|no-auto-host-bundle

Enable or disable host auto bundling.

cluster-active-active-routing|no-cluster-active-active-routing

Enable or disable active-active cluster routing.

routing-over-vlags|no-routing-over-vlags

Enable or disable routing to VLAGs from cluster links.

source-mac-miss to-cpu|copy-to-cpu        

Control unknown source MAC address learn behavior.

optimize-datapath disable|cluster-only|all

Specify the datapath optimization for cluster, fabric

and vRouter communication:

· disable: disables datapath optimization.

· cluster-only: enables datapath optimization

for cluster-only, where cluster traffic is

redirected to cluster 4094 vNIC.

· all: enables datapath optimization for fabric

and data traffic.

The default value is all.

cpu-class-enable|no-cpu-class-enable

Enable or disable CPU class.

usb-port|no-usb-port

Enable or disable the USB port on the front of the switch. This is only applicable to switches with ONVL.

use-igmp-snoop-l2|use-igmp-snoop-l3

Use Layer 2 or Layer 3 tables for IGMP snooping.

vle-tracking-timeout seconds

Specify vLE tracking timeout in seconds from 3 to 30 seconds.

pfc-buffer-limit pfc-buffer-limit-string

Percentage of global system buffer space allowed for PFC.

cosq-weight-auto|no-cosq-weight-auto

Specify if you want to adjust queue weights automatically.

lossless-mode|no-lossless-mode

Specifies lossless mode.

stagger-queries|no-stagger-queries

Specify if you want to stagger sending IGMP queries on the network.

qsfp28-port-mode none|6x40G|4x100G

Configure the QSFP28 port mode as 6x40G or 4x100G.

sfp28-port-mode 48x25G|36x25G+12x10G/1G|24x25G+24x10G/1G

Configure the sfp28 port mode using one of the three options.

Note: This parameter is available only on AS7326-56X / F9480-V Platforms.

host-refresh|no-host-refresh

Specify if you want to enable refreshing host ARP entries to keep L2 entries active.

proxy-conn-retry|no-proxy-conn-retry

Enable or disable proxy connection retry.

proxy-conn-max-retry integer

Specify the maximum number of proxy connection retry attempts from 0 to 20.

proxy-conn-retry-interval mseconds

Specify the number of milliseconds, from 100 to 2000,   to wait between proxy connection retry attempts.

nvos-debug-logging|no-nvos-debug-logging

Specify the logging mode.

optimize-rxlos|no-optimize-rxlos

Enable or disable processing of port modules that do not support RXLOS.

manage-l2-uuc-drop|no-manage-l2-uuc-drop

Enable or disable L2 Unknown Unicast Drop towards data port.

xcvr-link-debug|no-xcvr-link-debug

Enable or disable receiver link debug.

fastpath-bfd|no-fastpath-bfd

Enable or disable BFD path optimization.

linkscan-interval 10000..1000000

Specify the linkscan interval as a value between 10000μs, and 1000000μs. The default value is 150000μs.

Note: This parameter is not in effect when the link scan mode is hardware.

linkscan-mode software|hardware

Specify the link scan mode as hardware or software. Software link scan mode is enabled by default.

single-pass-l2-known-multicast|no-single-pass-l2-known-multicast

Specify to enable or disable single-pass L2 forwarding of known multicast traffic.

single-pass-flood|no-single-pass-flood

Enable or disable single-pass flood.

single-pass-riot|no-single-pass-riot

Specify to enable or disable the switches to perform routing in, and out of tunnels (RIOT) in a single pass (that is, without requiring the loopback trunk).

Note: This option is available only on NRU03, and NRU-S03 platforms, and on the Dell S4100, and S5200 Series.

hybrid-mode|no-hybrid-mode        

Specify to enable switch to working standard, and transparent mode.

batch-move-mac-hw-group-for-vlan-only|no-batch-move-mac-hw-group-for-vlan-only

Specify to enable or disable the HW batch move for MAC by group for VLAN network only.

memory-tracker|no-memory-tracker        

Enable memory footprint tracker.

symmetric-hash|no-symmetric-hash

Enables or disables symmetric hashing.

hash-suppress-unidir-fields|no-hash-suppress-unidir-fields

Enables or disables unidir fields suppression in symmetric hashing.

prioritize-rx-reasons|no-prioritize-rx-reasons

Specify to prioritize BCM RX Reasons over TCP Analytics vFlow.

hash-inner-ip-over-gre|no-hash-inner-ip-over-gre

Specify to control the fields used in the hash for v4/v6 over v4/v6 GRE.

multiple-tunnel-next-hops|no-multiple-tunnel-next-hops

Specify to enable multiple tunnel next hops on same port.

l3-use-host-table|no-l3-use-host-table

Specifies L3 Routes (such as EVPN type-5 routes) use host table for /32, and /128 routes.

offline-notification-new-thread|no-offline-notification-new-thread

Enables or disables new thread to send offline notifications when switch goes down.

uplink-oversubscription-action default|warn|error

Specifies nvOS action towards uplink oversubscription.

Defaults   All parameters enabled by default.

Access   Network Administrator

History   

Version 2.5.2

Command introduced.

Version 2.5.3

The parameters auto-host-trunk, and cluster-active-active-routing added.

Version 2.6.0

The parameters policy-based-routing, auto-vlag-bundle, lldp, block-loops, source-mac-miss, cpu-class, igmp-snooping and usb added.

Version 3.0.0

The parameters stagger-queries, cosq-weight-auto and vle-tracking-timeout added.

Version 3.1.0

The parameters host-refresh, proxy-conn-retry, proxy-conn-max-retry, and proxy-conn-retry-interval added.

Version 5.1.0

The parameter nvos-debug-logging|no-nvos-debug-logging added.

Version 5.2.0

The parameter fastpath-bfd|no-fastpath-bfd added

Version 6.0.0

The parameters linkscan-mode, and single-pass-flood added.

Version 6.0.1

The parameters cos-8-and-9-queue, and batch-move-mac-hwgroup-for-vlan-only added.

Version 6.1.1

The parameter offline-notification-new-thread added.

Version 7.0.0

The parameters sfp28-port-mode, and l3-use-host-table|no-l3-use-host-table added.

Usage   Use this command to enable or disable system settings. However, it is recommended that you do not modify the settings without consulting Pluribus Networks.

Examples  To disable auto-trunking, use the following syntax:

CLI (network-admin@switch) > system-settings-modify no-auto-trunk

north
    keyboard_arrow_up
    keyboard_arrow_down
    description
    print
    feedback
    support
    business
    rss_feed
    south