err-disable-modify

Physical ports are automatically disabled by NetVisor due to certain violations. For example, if a port receives BPDU messages from an edge port, NetVisor disables the port because receiving BPDUs on a edge port is a security violation. However, there is no way to indicate that the port is shut down because of a violation, and not because of physical link issues. 

This command modifies the port recovery settings on the switch.

Syntax   err-disable-modify

bpduguard|no-bpduguard

Specify if you want BPDU guard enabled.

linkflap|no-linkflap

Specify one of the options to enable or disable the recovery for link-flap errors.

Note: This parameter is supported only on NRU02, NRU03, and NRU-S0301 platforms.

macsecurity|no-macsecurity

Specify if you want MAC recovery enabled.

recovery-timer duration: #d#h#m#s

Specify the global recovery time (in days, hours, minutes, or seconds). The default timer value is 5 minutes.

Example: 20s or 1d or 10d20m3h15s

Defaults   None

Access   Network Administrator

History   

Version 2.6.0

Command introduced.

Version 7.1.0

The parameter linkflap|no-linkflap added.

Usage   Use this command to modify port error counters.

Examples  To modify port error counters, use the following syntax:

CLI (network-admin@switch) > err-disable-modify

north
    keyboard_arrow_up
    keyboard_arrow_down
    description
    print
    feedback
    support
    business
    rss_feed
    south