port-phy-show

This command is used to display information about the physical Layer 1 status of the local switch.

Syntax   port-phy-show

port port-list

Specifies the switch data port number, list of ports, or range of ports. Port numbers must be in the range of 1-64.

state off|admin-down|adminpwrdown|bist|dfe-tuning|down|local-fault|partially-up|remote-fault|up|failed

Specifies the state of the port PHY.

mode off|admin-down|adminpwrdown|bist|dfe-tuning|down|local-fault|partially-up|remote-fault|up|failed

Specifies the mode of the port PHY.

autoneg autoneg-string

Specifies the auto-negotiation setting of the port PHY.

speed speed-number

Specifies the speed of the port PHY.

eth-mode 1000base-x|sgmii|
disabled|1000base-kx|
2500base-x|6Gbase-kr|
6Gbase-cr|10Gbase-kr|
10Gbase-cr|10Gbase-sr|AN-73|Xaui|10Gbase-kx4|
10Gbase-cx4|24Gbase-kr4|24Gbase-cr4|
40Gbase-kr4| XLaui|40Gbase-cr4|
40Gbase-sr4|
no-phy-present|MII|GMII|TBI|10G-XGMII|1G-RGMII|10G-SFI|10G-XFI|GMII|disabled

Specify the Ethernet mode as 1000 base or Serial Gigabit Media Independent Interface (SGMII).

max-frame max-frame-number

Specifies the maximum number of frames.

learning on|off

Specifies the learning mode of the port PHY.

def-vlan def-vlan-number

Specifies the default VLAN identifier of the port PHY.

dfe-mode static|one-shot|
continuous|kr]

Specifies the Decision Feedback Equalizer (DFE) mode of the port PHY.

dfe-coarse not-started|in-progress|complete|error

Specifies the DFE status of the port PHY.

dfe-fine not-started|in-progress|complete|error

Specifies the DFE status of the port PHY.

fec fec-string

Specifies the FEC.

Defaults   None.

Access   CLI

History   

Version 1.2

Command introduced.

Version 2.1

The parameter, eth-mode, added.

Version 2.2

The options, disabled|1000base-kx|2500base-x|6Gbase-kr|6Gbase-cr|10Gbase-kr|10Gbase-cr|10Gbase-sr|AN-73|Xaui|10Gbase-kx4|10Gbase-cx4|24Gbase-kr4|24Gbase-cr4|40Gbase-kr4| XLaui|40Gbase-cr4|40Gbase-sr4|no-phy-present|MII|GMII|TBI| 10G-XGMII|1G-RGMII|10G-SFI|10G-XFI added.

Version 3.0.0

The parameter, link-quality, deprecated.

Version 3.1.0

The parameters, GII and disabled, added.

Usage   Switches are equipped with network data ports for host or inter-switch communication. Use this command to display the status of network data ports on the local switch.

Examples  To display the status of network data ports on the switch, use the following command:

CLI network-admin@switch > port-phy-show

port    state    speed    eth-mode       max-frame  link-quality   learning    def-vlan

17      up       1000     1000base-x     1540        n/a             on          1

19      up       10000    10Gbase-cr     10232       n/a             on          1

21      up       10000    10Gbase-cr     10232       n/a             on          1

23      up       10000    10Gbase-cr     10232       n/a             on          1

45      up       10000    10Gbase-cr     10232       n/a             on          1

65      up       10000    10Gbase-cr     10232       n/a             on          1

69      up       10000    10Gbase-cr     10232       n/a             on          1

north