port-phy-show
This command is used to display information about the physical Layer 1 status of the local switch.
Syntax port-phy-show
port port-list |
Specifies the switch data port number, list of ports, or range of ports. Port numbers must be in the range of 1-64. |
state off|admin-down|adminpwrdown|bist|dfe-tuning|down|local-fault|partially-up|remote-fault|up|failed |
Specifies the state of the port PHY. |
mode off|admin-down|adminpwrdown|bist|dfe-tuning|down|local-fault|partially-up|remote-fault|up|failed |
Specifies the mode of the port PHY. |
autoneg autoneg-string |
Specifies the auto-negotiation setting of the port PHY. |
speed speed-number |
Specifies the speed of the port PHY. |
eth-mode 1000base-x|sgmii| |
Specify the Ethernet mode as 1000 base or Serial Gigabit Media Independent Interface (SGMII). |
max-frame max-frame-number |
Specifies the maximum number of frames. |
learning on|off |
Specifies the learning mode of the port PHY. |
def-vlan def-vlan-number |
Specifies the default VLAN identifier of the port PHY. |
dfe-mode static|one-shot| |
Specifies the Decision Feedback Equalizer (DFE) mode of the port PHY. |
dfe-coarse not-started|in-progress|complete|error |
Specifies the DFE status of the port PHY. |
dfe-fine not-started|in-progress|complete|error |
Specifies the DFE status of the port PHY. |
fec fec-string |
Specifies the FEC. |
Defaults None.
Access CLI
History
Version 1.2 |
Command introduced. |
Version 2.1 |
The parameter, eth-mode, added. |
Version 2.2 |
The options, disabled|1000base-kx|2500base-x|6Gbase-kr|6Gbase-cr|10Gbase-kr|10Gbase-cr|10Gbase-sr|AN-73|Xaui|10Gbase-kx4|10Gbase-cx4|24Gbase-kr4|24Gbase-cr4|40Gbase-kr4| XLaui|40Gbase-cr4|40Gbase-sr4|no-phy-present|MII|GMII|TBI| 10G-XGMII|1G-RGMII|10G-SFI|10G-XFI added. |
Version 3.0.0 |
The parameter, link-quality, deprecated. |
Version 3.1.0 |
The parameters, GII and disabled, added. |
Usage Switches are equipped with network data ports for host or inter-switch communication. Use this command to display the status of network data ports on the local switch.
Examples To display the status of network data ports on the switch, use the following command:
CLI network-admin@switch > port-phy-show
port state speed eth-mode max-frame link-quality learning def-vlan
17 up 1000 1000base-x 1540 n/a on 1
19 up 10000 10Gbase-cr 10232 n/a on 1
21 up 10000 10Gbase-cr 10232 n/a on 1
23 up 10000 10Gbase-cr 10232 n/a on 1
45 up 10000 10Gbase-cr 10232 n/a on 1
65 up 10000 10Gbase-cr 10232 n/a on 1
69 up 10000 10Gbase-cr 10232 n/a on 1