Hardware Troubleshooting


First, confirm the overall health of the switch itself. 


The following commands validate basic communications and the overall health of the device.


CLI Usage Note

To execute command on a local switch only, use the command: switch-local. The display of an asterisk * denotes commands will run on the local switch. To revert to displaying information from all switches use the command: switch.

In some cases, a command's horizontal output may be wide and wrap inside the terminal CLI session. To display the information in a vertical format use the format command layout vertical. To revert, omit the format command.


Verify Management Port Settings


The management interface must be configured correctly for CLI access. If the management interface is not functional, check its configuration using the serial port or VGA/USB ports to confirm the settings, as shown below, are correctly configured for your management network.


Confirm the management interface is configured correctly with the command: switch-setup-show


CLI (network-admin@udev-leo1*) > switch-setup-show

switch-name:               udev-leo1

mgmt-ip:                   10.110.0.48/22

mgmt-ip-assignment:        static

mgmt-ip6:                  fe80::660e:94ff:fec0:a9f/64

mgmt-ip6-assignment:       autoconf

mgmt-link-state:           up

mgmt-link-speed:           1g

in-band-ip:                6.6.6.210/24

in-band-ip6:               fe80::640e:94ff:fe1b:d035/64

in-band-ip6-assign:        autoconf

gateway-ip:                10.110.0.1

dns-ip:                    10.135.2.13

dns-secondary-ip:          172.16.1.4

domain-name:               pluribusnetworks.com

ntp-server:                0.us.pool.ntp.org

ntp-secondary-server:      ntp.ubuntu.com

timezone:                  America/Los_Angeles

date:                      2020-09-15,13:40:27

hostid:                    201327131

location-id:               2

enable-host-ports:         yes

banner:                    * Welcome to Pluribus Networks Inc. Netvisor(R). This is a monitored system.   *

ntp:                       on

banner:                    *                ACCESS RESTRICTED TO AUTHORIZED USERS ONLY                    *

banner:                    * By using the Netvisor(R) CLI,you agree to the terms of the Pluribus Networks *

banner:                    * End User License Agreement (EULA). The EULA can be accessed via              *

banner:                    * http://www.pluribusnetworks.com/eula or by using the command "eula-show"     *


Switch Setup Show - Local and Fabric


Use the switch-setup-show command to obtain switch information at the single switch level (local scope):


CLI (network-admin@corvus-ring-1) > switch-setup-show

switch-name:               corvus-ring-1

mgmt-ip:                   10.13.2.29/23

mgmt-ip-assignment:        static

mgmt-ip6:                  fe80::e6f0:4ff:fec9:e13b/64

mgmt-ip6-assignment:       autoconf

mgmt-link-state:           up

mgmt-link-speed:           1g

in-band-ip:                192.16.10.161/29

in-band-ip6:               fe80::640e:94ff:fe84:de1e/64

in-band-ip6-assign:        autoconf

gateway-ip:                10.13.2.1

dns-ip:                    10.135.2.13

dns-secondary-ip:          10.20.4.1

domain-name:               pluribusnetworks.com

ntp-server:                10.135.2.13

ntp-secondary-server:      ntp.ubuntu.com

timezone:                  America/Los_Angeles

date:                      2020-09-28,20:26:38

hostid:                    184553860

location-id:               13

enable-host-ports:         yes

banner:                    * Welcome to Pluribus Networks Inc. Netvisor(R). This is a monitored system.   *

device-id:                 97CJXC2

ntp:                       on

banner:                    *                ACCESS RESTRICTED TO AUTHORIZED USERS ONLY                    *

banner:                    * By using the Netvisor(R) CLI,you agree to the terms of the Pluribus Networks *

banner:                    * End User License Agreement (EULA). The EULA can be accessed via              *

banner:                    * http://www.pluribusnetworks.com/eula or by using the command "eula-show"     *


Use the switch * switch-setup-show command to obtain switch information on all switches at the fabric level (fabric scope):


CLI (network-admin@corvus-ring-1) > switch * switch-setup-show

switch-name:               corvus-ring-1

mgmt-ip:                   10.13.2.29/23

mgmt-ip-assignment:        static

mgmt-ip6:                  fe80::e6f0:4ff:fec9:e13b/64

mgmt-ip6-assignment:       autoconf

mgmt-link-state:           up

mgmt-link-speed:           1g

in-band-ip:                192.16.10.161/29

in-band-ip6:               fe80::640e:94ff:fe84:de1e/64

in-band-ip6-assign:        autoconf

gateway-ip:                10.13.2.1

dns-ip:                    10.135.2.13

dns-secondary-ip:          10.20.4.1

domain-name:               pluribusnetworks.com

ntp-server:                10.135.2.13

ntp-secondary-server:      ntp.ubuntu.com

timezone:                  America/Los_Angeles

date:                      2020-09-28,20:26:46

hostid:                    184553860

location-id:               13

enable-host-ports:         yes

banner:                    * Welcome to Pluribus Networks Inc. Netvisor(R). This is a monitored system.   *

device-id:                 97CJXC2

ntp:                       on

banner:                    *                ACCESS RESTRICTED TO AUTHORIZED USERS ONLY                    *

banner:                    * By using the Netvisor(R) CLI,you agree to the terms of the Pluribus Networks *

banner:                    * End User License Agreement (EULA). The EULA can be accessed via              *

banner:                    * http://www.pluribusnetworks.com/eula or by using the command "eula-show"     *

switch-name:               corvus-ring-2

mgmt-ip:                   10.13.2.30/23

mgmt-ip-assignment:        static

mgmt-ip6:                  fe80::e6f0:4ff:febd:d700/64

mgmt-ip6-assignment:       autoconf

mgmt-link-state:           up

mgmt-link-speed:           1g

in-band-ip:                192.16.10.169/29

in-band-ip6:               fe80::640e:94ff:fe83:f816/64

in-band-ip6-assign:        autoconf

gateway-ip:                10.13.2.1

dns-ip:                    10.135.2.13

dns-secondary-ip:          10.20.4.1

domain-name:               pluribusnetworks.com

ntp-server:                10.135.2.13

ntp-secondary-server:      ntp.ubuntu.com

timezone:                  America/Los_Angeles

date:                      2020-09-28,20:26:46

hostid:                    184553859

location-id:               14

enable-host-ports:         yes

banner:                    * Welcome to Pluribus Networks Inc. Netvisor(R). This is a monitored system.   *

device-id:                 B5QHXC2

ntp:                       on

banner:                    *                ACCESS RESTRICTED TO AUTHORIZED USERS ONLY                    *

banner:                    * By using the Netvisor(R) CLI,you agree to the terms of the Pluribus Networks *

banner:                    * End User License Agreement (EULA). The EULA can be accessed via              *

banner:                    * http://www.pluribusnetworks.com/eula or by using the command "eula-show"     *

switch-name:               pavo-ring-7

mgmt-ip:                   10.13.2.38/23

mgmt-ip-assignment:        static

mgmt-ip6:                  fe80::2204:fff:fe52:2e58/64

mgmt-ip6-assignment:       autoconf

mgmt-link-state:           up

mgmt-link-speed:           1g

in-band-ip:                192.16.10.145/29

in-band-ip6:               fe80::640e:94ff:fe83:2ea3/64

in-band-ip6-assign:        autoconf

gateway-ip:                10.13.2.1

dns-ip:                    10.135.2.13

dns-secondary-ip:          10.20.4.1

domain-name:               pluribusnetworks.com

ntp-server:                0.ubuntu.pool.ntp.org

ntp-secondary-server:      1.ubuntu.pool.ntp.org

timezone:                  America/Los_Angeles

date:                      2020-09-28,20:26:47

hostid:                    150997635

location-id:               5

enable-host-ports:         yes

banner:                    * Welcome to Pluribus Networks Inc. Netvisor(R). This is a monitored system.   *

device-id:                 JWH1PK2

ntp:                       on

banner:                    *                ACCESS RESTRICTED TO AUTHORIZED USERS ONLY                    *

banner:                    * By using the Netvisor(R) CLI,you agree to the terms of the Pluribus Networks *

banner:                    * End User License Agreement (EULA). The EULA can be accessed via              *

banner:                    * http://www.pluribusnetworks.com/eula or by using the command "eula-show"     *

switch-name:               pavo-ring-8

mgmt-ip:                   10.13.2.39/23

mgmt-ip-assignment:        static

mgmt-ip6:                  fe80::2204:fff:fe52:2dd8/64

mgmt-ip6-assignment:       autoconf

mgmt-link-state:           up

mgmt-link-speed:           1g

in-band-ip:                192.16.10.153/29

in-band-ip6:               fe80::640e:94ff:fe8c:e139/64

in-band-ip6-assign:        autoconf

gateway-ip:                10.13.2.1

dns-ip:                    10.135.2.13

domain-name:               pluribus.networks.com

ntp-server:                0.ubuntu.pool.ntp.org

ntp-secondary-server:      1.ubuntu.pool.ntp.org

timezone:                  America/Los_Angeles

date:                      2020-09-28,20:26:47

hostid:                    150997644

location-id:               12

enable-host-ports:         yes

banner:                    * Welcome to Pluribus Networks Inc. Netvisor(R). This is a monitored system.   *

device-id:                 FWH1PK2

ntp:                       on

banner:                    *                ACCESS RESTRICTED TO AUTHORIZED USERS ONLY                    *

banner:                    * By using the Netvisor(R) CLI,you agree to the terms of the Pluribus Networks *

banner:                    * End User License Agreement (EULA). The EULA can be accessed via              *

banner:                    * http://www.pluribusnetworks.com/eula or by using the command "eula-show"     *

switch-name:               pavo-ring-12

mgmt-ip:                   10.13.2.43/23

mgmt-ip-assignment:        static

mgmt-ip6:                  fe80::2204:fff:fe52:2d58/64

mgmt-ip6-assignment:       autoconf

mgmt-link-state:           up

mgmt-link-speed:           1g

in-band-ip:                192.16.10.9/29

in-band-ip6:               fe80::640e:94ff:fe86:10e7/64

in-band-ip6-assign:        autoconf

gateway-ip:                10.13.2.1

dns-ip:                    10.135.2.13

dns-secondary-ip:          10.20.4.1

domain-name:               pluribusnetworks.com

ntp-server:                0.ubuntu.pool.ntp.org

ntp-secondary-server:      1.ubuntu.pool.ntp.org

timezone:                  America/Los_Angeles

date:                      2020-09-28,20:26:47

hostid:                    150997638

location-id:               1

enable-host-ports:         yes

banner:                    * Welcome to Pluribus Networks Inc. Netvisor(R). This is a monitored system.   *

device-id:                 GWH1PK2

ntp:                       on

banner:                    *                ACCESS RESTRICTED TO AUTHORIZED USERS ONLY                    *

banner:                    * By using the Netvisor(R) CLI,you agree to the terms of the Pluribus Networks *

banner:                    * End User License Agreement (EULA). The EULA can be accessed via              *

banner:                    * http://www.pluribusnetworks.com/eula or by using the command "eula-show"     *

switch-name:               pavo-ring-9

mgmt-ip:                   10.13.2.40/23

mgmt-ip-assignment:        static

mgmt-ip6:                  fe80::2204:fff:fe52:2858/64

mgmt-ip6-assignment:       autoconf

mgmt-link-state:           up

mgmt-link-speed:           1g

in-band-ip:                192.16.10.137/29

in-band-ip6:               fe80::640e:94ff:fe87:d853/64

in-band-ip6-assign:        autoconf

gateway-ip:                10.13.2.1

dns-ip:                    10.135.2.13

dns-secondary-ip:          10.20.4.1

domain-name:               pluribusnetworks.com

ntp-server:                0.ubuntu.pool.ntp.org

ntp-secondary-server:      1.ubuntu.pool.ntp.org

timezone:                  America/Los_Angeles

date:                      2020-09-28,20:26:47

hostid:                    150997639

location-id:               4

enable-host-ports:         yes

banner:                    * Welcome to Pluribus Networks Inc. Netvisor(R). This is a monitored system.   *

device-id:                 4WH1PK2

ntp:                       on

banner:                    *                ACCESS RESTRICTED TO AUTHORIZED USERS ONLY                    *

banner:                    * By using the Netvisor(R) CLI,you agree to the terms of the Pluribus Networks *

banner:                    * End User License Agreement (EULA). The EULA can be accessed via              *

banner:                    * http://www.pluribusnetworks.com/eula or by using the command "eula-show"     *

switch-name:               pavo-ring-11

mgmt-ip:                   10.13.2.42/23

mgmt-ip-assignment:        static

mgmt-ip6:                  fe80::2204:fff:fe52:2bd8/64

mgmt-ip6-assignment:       autoconf

mgmt-link-state:           up

mgmt-link-speed:           1g

in-band-ip:                192.16.10.1/29

in-band-ip6:               fe80::640e:94ff:fe85:237/64

in-band-ip6-assign:        autoconf

gateway-ip:                10.13.2.1

dns-ip:                    10.135.2.13

dns-secondary-ip:          10.20.4.1

domain-name:               pluribusnetworks.com

ntp-server:                0.ubuntu.pool.ntp.org

ntp-secondary-server:      1.ubuntu.pool.ntp.org

timezone:                  America/Los_Angeles

date:                      2020-09-28,20:26:47

hostid:                    150997637

location-id:               9

enable-host-ports:         yes

banner:                    * Welcome to Pluribus Networks Inc. Netvisor(R). This is a monitored system.   *

device-id:                 9WH1PK2

ntp:                       on

banner:                    *                ACCESS RESTRICTED TO AUTHORIZED USERS ONLY                    *

banner:                    * By using the Netvisor(R) CLI,you agree to the terms of the Pluribus Networks *

banner:                    * End User License Agreement (EULA). The EULA can be accessed via              *

banner:                    * http://www.pluribusnetworks.com/eula or by using the command "eula-show"     *

switch-name:               pavo-ring-2

mgmt-ip:                   10.13.2.20/23

mgmt-ip-assignment:        static

mgmt-ip6:                  fe80::2204:fff:fe36:5099/64

mgmt-ip6-assignment:       autoconf

mgmt-link-state:           up

mgmt-link-speed:           1g

in-band-ip:                192.16.10.25/29

in-band-ip6:               fe80::640e:94ff:fe3d:91a/64

in-band-ip6-assign:        autoconf

gateway-ip:                10.13.2.1

dns-ip:                    10.135.2.13

dns-secondary-ip:          10.20.4.1

domain-name:               pluribus.networks.com

ntp-server:                0.ubuntu.pool.ntp.org

ntp-secondary-server:      1.ubuntu.pool.ntp.org

timezone:                  America/Los_Angeles

date:                      2020-09-28,20:26:47

hostid:                    150997565

location-id:               11

enable-host-ports:         yes

banner:                    * Welcome to Pluribus Networks Inc. Netvisor(R). This is a monitored system.   *

device-id:                 J7STNK2

ntp:                       on

banner:                    *                ACCESS RESTRICTED TO AUTHORIZED USERS ONLY                    *

banner:                    * By using the Netvisor(R) CLI,you agree to the terms of the Pluribus Networks *

banner:                    * End User License Agreement (EULA). The EULA can be accessed via              *

banner:                    * http://www.pluribusnetworks.com/eula or by using the command "eula-show"     *

switch-name:               pavo-ring-1

mgmt-ip:                   10.13.2.19/23

mgmt-ip-assignment:        static

mgmt-ip6:                  fe80::2204:fff:fe36:5999/64

mgmt-ip6-assignment:       autoconf

mgmt-link-state:           up

mgmt-link-speed:           1g

in-band-ip:                192.16.10.17/29

in-band-ip6:               fe80::640e:94ff:fe3c:8b05/64

in-band-ip6-assign:        autoconf

gateway-ip:                10.13.2.1

dns-ip:                    10.135.2.13

dns-secondary-ip:          10.20.4.1

domain-name:               pluribus.networks.com

ntp-server:                0.ubuntu.pool.ntp.org

ntp-secondary-server:      1.ubuntu.pool.ntp.org

timezone:                  America/Los_Angeles

date:                      2020-09-28,20:26:47

hostid:                    150997564

location-id:               10

enable-host-ports:         yes

banner:                    * Welcome to Pluribus Networks Inc. Netvisor(R). This is a monitored system.   *

device-id:                 99STNK2

ntp:                       on

banner:                    *                ACCESS RESTRICTED TO AUTHORIZED USERS ONLY                    *

banner:                    * By using the Netvisor(R) CLI,you agree to the terms of the Pluribus Networks *

banner:                    * End User License Agreement (EULA). The EULA can be accessed via              *

banner:                    * http://www.pluribusnetworks.com/eula or by using the command "eula-show"     *

switch-name:               pavo-ring-6

mgmt-ip:                   10.13.2.37/23

mgmt-ip-assignment:        static

mgmt-ip6:                  fe80::2204:fff:fe52:2a58/64

mgmt-ip6-assignment:       autoconf

mgmt-link-state:           up

mgmt-link-speed:           1g

in-band-ip:                192.16.10.129/29

in-band-ip6:               fe80::640e:94ff:fe8a:d753/64

in-band-ip6-assign:        autoconf

gateway-ip:                10.13.2.1

dns-ip:                    10.135.2.13

dns-secondary-ip:          10.20.4.1

domain-name:               pluribusnetworks.com

ntp-server:                0.ubuntu.pool.ntp.org

ntp-secondary-server:      1.ubuntu.pool.ntp.org

timezone:                  America/Los_Angeles

date:                      2020-09-28,20:26:47

hostid:                    150997642

location-id:               3

enable-host-ports:         yes

banner:                    * Welcome to Pluribus Networks Inc. Netvisor(R). This is a monitored system.   *

device-id:                 8WH1PK2

ntp:                       on

banner:                    *                ACCESS RESTRICTED TO AUTHORIZED USERS ONLY                    *

banner:                    * By using the Netvisor(R) CLI,you agree to the terms of the Pluribus Networks *

banner:                    * End User License Agreement (EULA). The EULA can be accessed via              *

banner:                    * http://www.pluribusnetworks.com/eula or by using the command "eula-show"     *

switch-name:               pavo-ring-5

mgmt-ip:                   10.13.2.36/23

mgmt-ip-assignment:        static

mgmt-ip6:                  fe80::2204:fff:fe52:2ed8/64

mgmt-ip6-assignment:       autoconf

mgmt-link-state:           up

mgmt-link-speed:           1g

in-band-ip:                192.16.10.121/29

in-band-ip6:               fe80::640e:94ff:fe89:5a03/64

in-band-ip6-assign:        autoconf

gateway-ip:                10.13.2.1

dns-ip:                    10.135.2.13

dns-secondary-ip:          10.20.4.1

domain-name:               pluribusnetworks.com

ntp-server:                0.ubuntu.pool.ntp.org

ntp-secondary-server:      1.ubuntu.pool.ntp.org

timezone:                  America/Los_Angeles

date:                      2020-09-28,20:26:47

hostid:                    150997641

location-id:               6

enable-host-ports:         yes

banner:                    * Welcome to Pluribus Networks Inc. Netvisor(R). This is a monitored system.   *

device-id:                 HWH1PK2

ntp:                       on

banner:                    *                ACCESS RESTRICTED TO AUTHORIZED USERS ONLY                    *

banner:                    * By using the Netvisor(R) CLI,you agree to the terms of the Pluribus Networks *

banner:                    * End User License Agreement (EULA). The EULA can be accessed via              *

banner:                    * http://www.pluribusnetworks.com/eula or by using the command "eula-show"     *

switch-name:               delph-ring-1

mgmt-ip:                   10.13.2.21/23

mgmt-ip-assignment:        static

mgmt-ip6:                  fe80::1618:77ff:fe26:e39/64

mgmt-ip6-assignment:       autoconf

mgmt-link-state:           up

mgmt-link-speed:           1g

in-band-ip:                192.16.10.41/29

in-band-ip6:               fe80::640e:94ff:fe3b:bc0e/64

in-band-ip6-assign:        autoconf

gateway-ip:                10.13.2.1

dns-ip:                    10.135.2.3

dns-secondary-ip:          10.20.4.1

domain-name:               pluribus.networks.com

ntp-server:                0.ubuntu.pool.ntp.org

ntp-secondary-server:      1.ubuntu.pool.ntp.org

timezone:                  America/Los_Angeles

date:                      2020-09-28,20:26:47

hostid:                    150997563

location-id:               17

enable-host-ports:         yes

banner:                    * Welcome to Pluribus Networks Inc. Netvisor(R). This is a monitored system.   *

device-id:                 4837XC2

ntp:                       on

banner:                    *                ACCESS RESTRICTED TO AUTHORIZED USERS ONLY                    *

banner:                    * By using the Netvisor(R) CLI,you agree to the terms of the Pluribus Networks *

banner:                    * End User License Agreement (EULA). The EULA can be accessed via              *

banner:                    * http://www.pluribusnetworks.com/eula or by using the command "eula-show"     *

switch-name:               delph-ring-4

mgmt-ip:                   10.13.2.32/23

mgmt-ip-assignment:        static

mgmt-ip6:                  fe80::e6f0:4ff:fe96:899d/64

mgmt-ip6-assignment:       autoconf

mgmt-link-state:           up

mgmt-link-speed:           1g

in-band-ip:                192.16.10.105/29

in-band-ip6:               fe80::640e:94ff:fe17:fa5c/64

in-band-ip6-assign:        autoconf

gateway-ip:                10.13.2.1

dns-ip:                    10.135.2.13

dns-secondary-ip:          10.20.4.1

domain-name:               pluribusnetworks.com

ntp-server:                10.135.2.13

ntp-secondary-server:      ntp.ubuntu.com

timezone:                  America/Los_Angeles

date:                      2020-09-28,20:26:47

hostid:                    150997015

location-id:               19

enable-host-ports:         yes

banner:                    * Welcome to Pluribus Networks Inc. Netvisor(R). This is a monitored system.   *

device-id:                 1FHDXC2

ntp:                       on

banner:                    *                ACCESS RESTRICTED TO AUTHORIZED USERS ONLY                    *

banner:                    * By using the Netvisor(R) CLI,you agree to the terms of the Pluribus Networks *

banner:                    * End User License Agreement (EULA). The EULA can be accessed via              *

banner:                    * http://www.pluribusnetworks.com/eula or by using the command "eula-show"     *

switch-name:               delph-ring-3

mgmt-ip:                   10.13.2.31/23

mgmt-ip-assignment:        static

mgmt-ip6:                  fe80::e6f0:4ff:fe96:879d/64

mgmt-ip6-assignment:       autoconf

mgmt-link-state:           up

mgmt-link-speed:           1g

in-band-ip:                192.16.10.97/29

in-band-ip6:               2093::17:1:1:185/64

in-band-ip6-assign:        static

gateway-ip:                10.13.2.1

dns-ip:                    10.135.2.13

dns-secondary-ip:          10.20.4.1

domain-name:               pluribusnetworks.com

ntp-server:                10.135.2.13

ntp-secondary-server:      ntp.ubuntu.com

timezone:                  America/Los_Angeles

date:                      2020-09-28,20:26:47

hostid:                    150996898

location-id:               20

enable-host-ports:         yes

banner:                    * Welcome to Pluribus Networks Inc. Netvisor(R). This is a monitored system.   *

device-id:                 FDHDXC2

ntp:                       on

banner:                    *                ACCESS RESTRICTED TO AUTHORIZED USERS ONLY                    *

banner:                    * By using the Netvisor(R) CLI,you agree to the terms of the Pluribus Networks *

banner:                    * End User License Agreement (EULA). The EULA can be accessed via              *

banner:                    * http://www.pluribusnetworks.com/eula or by using the command "eula-show"     *

switch-name:               scorp-ring-2

mgmt-ip:                   10.13.2.28/23

mgmt-ip-assignment:        static

mgmt-ip6:                  fe80::e6f0:4ff:fe8e:95a7/64

mgmt-ip6-assignment:       autoconf

mgmt-link-state:           up

mgmt-link-speed:           1g

in-band-ip:                192.16.10.89/29

in-band-ip6:               fe80::640e:94ff:fe92:96c2/64

in-band-ip6-assign:        autoconf

gateway-ip:                10.13.2.1

dns-ip:                    10.135.2.13

dns-secondary-ip:          10.20.4.1

domain-name:               pluribusnetworks.com

ntp-server:                10.135.2.13

ntp-secondary-server:      ntp.ubuntu.com

timezone:                  America/Los_Angeles

date:                      2020-09-28,20:26:47

hostid:                    150997138

location-id:               21

enable-host-ports:         yes

banner:                    * Welcome to Pluribus Networks Inc. Netvisor(R). This is a monitored system.   *

device-id:                 JZ1DXC2

ntp:                       on

banner:                    *                ACCESS RESTRICTED TO AUTHORIZED USERS ONLY                    *

banner:                    * By using the Netvisor(R) CLI,you agree to the terms of the Pluribus Networks *

banner:                    * End User License Agreement (EULA). The EULA can be accessed via              *

banner:                    * http://www.pluribusnetworks.com/eula or by using the command "eula-show"     *

switch-name:               delph-ring-2

mgmt-ip:                   10.13.2.22/23

mgmt-ip-assignment:        static

mgmt-ip6:                  fe80::1618:77ff:fe26:1939/64

mgmt-ip6-assignment:       autoconf

mgmt-link-state:           up

mgmt-link-speed:           1g

in-band-ip:                192.16.10.49/29

in-band-ip6:               fe80::640e:94ff:fef7:ee96/64

in-band-ip6-assign:        autoconf

gateway-ip:                10.13.2.1

dns-ip:                    10.135.2.13

dns-secondary-ip:          10.20.4.1

domain-name:               pluribus.networks.com

ntp-server:                0.ubuntu.pool.ntp.org

ntp-secondary-server:      1.ubuntu.pool.ntp.org

timezone:                  America/Los_Angeles

date:                      2020-09-28,20:26:47

hostid:                    184555767

location-id:               22

enable-host-ports:         yes

banner:                    * Welcome to Pluribus Networks Inc. Netvisor(R). This is a monitored system.   *

device-id:                 F937XC2

ntp:                       on

banner:                    *                ACCESS RESTRICTED TO AUTHORIZED USERS ONLY                    *

banner:                    * By using the Netvisor(R) CLI,you agree to the terms of the Pluribus Networks *

banner:                    * End User License Agreement (EULA). The EULA can be accessed via              *

banner:                    * http://www.pluribusnetworks.com/eula or by using the command "eula-show"     *

switch-name:               pavo-ring-3

mgmt-ip:                   10.13.2.34/23

mgmt-ip-assignment:        static

mgmt-ip6:                  fe80::2204:fff:fe52:2c58/64

mgmt-ip6-assignment:       autoconf

mgmt-link-state:           up

mgmt-link-speed:           1g

in-band-ip:                192.16.10.57/29

in-band-ip6:               fe80::640e:94ff:fe84:105e/64

in-band-ip6-assign:        autoconf

gateway-ip:                10.13.2.1

dns-ip:                    10.135.2.13

dns-secondary-ip:          10.20.4.1

domain-name:               pluribusnetworks.com

ntp-server:                0.ubuntu.pool.ntp.org

ntp-secondary-server:      1.ubuntu.pool.ntp.org

timezone:                  America/Los_Angeles

date:                      2020-09-28,20:26:47

hostid:                    150997636

location-id:               23

enable-host-ports:         yes

banner:                    * Welcome to Pluribus Networks Inc. Netvisor(R). This is a monitored system.   *

device-id:                 DWH1PK2

ntp:                       on

banner:                    *                ACCESS RESTRICTED TO AUTHORIZED USERS ONLY                    *

banner:                    * By using the Netvisor(R) CLI,you agree to the terms of the Pluribus Networks *

banner:                    * End User License Agreement (EULA). The EULA can be accessed via              *

banner:                    * http://www.pluribusnetworks.com/eula or by using the command "eula-show"     *

switch-name:               hydra-ring-2

mgmt-ip:                   10.13.2.24/23

mgmt-ip-assignment:        static

mgmt-ip6:                  fe80::e6f0:4ff:fe87:336d/64

mgmt-ip6-assignment:       autoconf

mgmt-link-state:           up

mgmt-link-speed:           1g

in-band-ip:                192.16.10.73/29

in-band-ip6:               fe80::640e:94ff:fe02:9d81/64

in-band-ip6-assign:        autoconf

gateway-ip:                10.13.2.1

dns-ip:                    10.135.2.13

dns-secondary-ip:          10.20.4.1

domain-name:               pluribusnetworks.com

ntp-server:                10.135.2.13

ntp-secondary-server:      ntp.ubuntu.com

timezone:                  America/Los_Angeles

date:                      2020-09-28,20:26:47

hostid:                    150996738

location-id:               25

enable-host-ports:         yes

banner:                    * Welcome to Pluribus Networks Inc. Netvisor(R). This is a monitored system.   *

device-id:                 DMQCXC2

ntp:                       on

banner:                    *                ACCESS RESTRICTED TO AUTHORIZED USERS ONLY                    *

banner:                    * By using the Netvisor(R) CLI,you agree to the terms of the Pluribus Networks *

banner:                    * End User License Agreement (EULA). The EULA can be accessed via              *

banner:                    * http://www.pluribusnetworks.com/eula or by using the command "eula-show"     *

switch-name:               scorp-ring-1

mgmt-ip:                   10.13.2.27/23

mgmt-ip-assignment:        static

mgmt-ip6:                  fe80::e6f0:4ff:fe8e:a6a7/64

mgmt-ip6-assignment:       autoconf

mgmt-link-state:           up

mgmt-link-speed:           1g

in-band-ip:                192.16.10.81/29

in-band-ip6:               fe80::640e:94ff:fedf:dbc9/64

in-band-ip6-assign:        autoconf

gateway-ip:                10.13.2.1

dns-ip:                    10.135.2.13

dns-secondary-ip:          10.20.4.1

domain-name:               pluribusnetworks.com

ntp-server:                10.135.2.13

ntp-secondary-server:      0.ubuntu.pool.ntp.org

timezone:                  America/Los_Angeles

date:                      2020-09-28,20:26:47

hostid:                    150997215

location-id:               18

enable-host-ports:         yes

banner:                    * Welcome to Pluribus Networks Inc. Netvisor(R). This is a monitored system.   *

device-id:                 312DXC2

ntp:                       on

banner:                    *                ACCESS RESTRICTED TO AUTHORIZED USERS ONLY                    *

banner:                    * By using the Netvisor(R) CLI,you agree to the terms of the Pluribus Networks *

banner:                    * End User License Agreement (EULA). The EULA can be accessed via              *

banner:                    * http://www.pluribusnetworks.com/eula or by using the command "eula-show"     *

switch-name:               vnv-ring-1

mgmt-ip:                   10.13.2.51/23

mgmt-ip-assignment:        static

mgmt-ip6:                  fe80::640e:94ff:fe23:b28a/64

mgmt-ip6-assignment:       autoconf

in-band-ip:                192.16.10.185/29

in-band-ip6:               fe80::c5e:45ff:fec3:89a0/64

in-band-ip6-assign:        autoconf

gateway-ip:                10.13.2.1

ntp-server:                0.ubuntu.pool.ntp.org

ntp-secondary-server:      1.ubuntu.pool.ntp.org

timezone:                  America/Los_Angeles

date:                      2020-09-28,20:26:47

hostid:                    211268643

location-id:               27

enable-host-ports:         yes

banner:                    * Welcome to Pluribus Networks Inc. Netvisor(R). This is a monitored system.   *

ntp:                       on

banner:                    *                ACCESS RESTRICTED TO AUTHORIZED USERS ONLY                    *

banner:                    * By using the Netvisor(R) CLI,you agree to the terms of the Pluribus Networks *

banner:                    * End User License Agreement (EULA). The EULA can be accessed via              *

banner:                    * http://www.pluribusnetworks.com/eula or by using the command "eula-show"     *

switch-name:               pavo-ring-4

mgmt-ip:                   10.13.2.35/23

mgmt-ip-assignment:        static

mgmt-ip6:                  fe80::2204:fff:fe52:2758/64

mgmt-ip6-assignment:       autoconf

mgmt-link-state:           up

mgmt-link-speed:           1g

in-band-ip:                192.16.10.113/29

in-band-ip6:               fe80::640e:94ff:fe88:d739/64

in-band-ip6-assign:        autoconf

gateway-ip:                10.13.2.1

dns-ip:                    10.135.2.13

dns-secondary-ip:          10.20.4.1

domain-name:               pluribusnetworks.com

ntp-server:                0.ubuntu.pool.ntp.org

ntp-secondary-server:      1.ubuntu.pool.ntp.org

timezone:                  America/Los_Angeles

date:                      2020-09-28,20:26:47

hostid:                    150997640

location-id:               7

enable-host-ports:         yes

banner:                    * Welcome to Pluribus Networks Inc. Netvisor(R). This is a monitored system.   *

device-id:                 2WH1PK2

ntp:                       on

banner:                    *                ACCESS RESTRICTED TO AUTHORIZED USERS ONLY                    *

banner:                    * By using the Netvisor(R) CLI,you agree to the terms of the Pluribus Networks *

banner:                    * End User License Agreement (EULA). The EULA can be accessed via              *

banner:                    * http://www.pluribusnetworks.com/eula or by using the command "eula-show"     *

switch-name:               hydra-ring-1

mgmt-ip:                   10.13.2.23/23

mgmt-ip-assignment:        static

mgmt-ip6:                  fe80::e6f0:4ff:fe87:386d/64

mgmt-ip6-assignment:       autoconf

mgmt-link-state:           up

mgmt-link-speed:           1g

in-band-ip:                192.16.10.65/29

in-band-ip6:               fe80::640e:94ff:fe03:1cdc/64

in-band-ip6-assign:        autoconf

gateway-ip:                10.13.2.1

dns-ip:                    10.135.2.13

dns-secondary-ip:          10.20.4.1

domain-name:               pluribusnetworks.com

ntp-server:                10.135.2.13

ntp-secondary-server:      ntp.ubuntu.com

timezone:                  America/Los_Angeles

date:                      2020-09-28,20:26:47

hostid:                    150996739

location-id:               24

enable-host-ports:         yes

banner:                    * Welcome to Pluribus Networks Inc. Netvisor(R). This is a monitored system.   *

device-id:                 2NQCXC2

ntp:                       on

banner:                    *                ACCESS RESTRICTED TO AUTHORIZED USERS ONLY                    *

banner:                    * By using the Netvisor(R) CLI,you agree to the terms of the Pluribus Networks *

banner:                    * End User License Agreement (EULA). The EULA can be accessed via              *

banner:                    * http://www.pluribusnetworks.com/eula or by using the command "eula-show"     *

switch-name:               pyxis-ring-2

mgmt-ip:                   10.13.2.66/23

mgmt-ip-assignment:        static

mgmt-ip6:                  fe80::1e72:1dff:fee0:94ff/64

mgmt-ip6-assignment:       autoconf

mgmt-link-state:           up

mgmt-link-speed:           1g

in-band-ip:                192.16.10.201/29

in-band-ip6:               fe80::640e:94ff:fef5:d3e5/64

in-band-ip6-assign:        autoconf

gateway-ip:                10.13.2.1

dns-ip:                    10.135.2.3

dns-secondary-ip:          10.20.4.1

domain-name:               pluribus.networks.com

ntp-server:                0.ubuntu.pool.ntp.org

ntp-secondary-server:      1.ubuntu.pool.ntp.org

timezone:                  America/Los_Angeles

date:                      2020-09-28,20:26:46

hostid:                    184557813

location-id:               30

enable-host-ports:         yes

banner:                    * Welcome to Pluribus Networks Inc. Netvisor(R). This is a monitored system.   *

device-id:                 DN7QY03

ntp:                       on

banner:                    *                ACCESS RESTRICTED TO AUTHORIZED USERS ONLY                    *

banner:                    * By using the Netvisor(R) CLI,you agree to the terms of the Pluribus Networks *

banner:                    * End User License Agreement (EULA). The EULA can be accessed via              *

banner:                    * http://www.pluribusnetworks.com/eula or by using the command "eula-show"     *

switch-name:               pyxis-ring-3

mgmt-ip:                   10.13.2.68/23

mgmt-ip-assignment:        static

mgmt-ip6:                  fe80::1e72:1dff:fee0:b1ff/64

mgmt-ip6-assignment:       autoconf

mgmt-link-state:           up

mgmt-link-speed:           1g

in-band-ip:                192.16.10.209/29

in-band-ip6:               fe80::640e:94ff:fef6:970e/64

in-band-ip6-assign:        autoconf

gateway-ip:                10.13.2.1

dns-ip:                    10.135.2.3

dns-secondary-ip:          10.20.4.1

domain-name:               pluribus.networks.com

ntp-server:                0.ubuntu.pool.ntp.org

ntp-secondary-server:      1.ubuntu.pool.ntp.org

timezone:                  America/Los_Angeles

date:                      2020-09-28,20:26:46

hostid:                    184557814

location-id:               28

enable-host-ports:         yes

banner:                    * Welcome to Pluribus Networks Inc. Netvisor(R). This is a monitored system.   *

device-id:                 6R7QY03

ntp:                       on

banner:                    *                ACCESS RESTRICTED TO AUTHORIZED USERS ONLY                    *

banner:                    * By using the Netvisor(R) CLI,you agree to the terms of the Pluribus Networks *

banner:                    * End User License Agreement (EULA). The EULA can be accessed via              *

banner:                    * http://www.pluribusnetworks.com/eula or by using the command "eula-show"     *

switch-name:               pyxis-ring-1

mgmt-ip:                   10.13.2.65/23

mgmt-ip-assignment:        static

mgmt-ip6:                  fe80::1e72:1dff:fee0:32ff/64

mgmt-ip6-assignment:       autoconf

mgmt-link-state:           up

mgmt-link-speed:           1g

in-band-ip:                192.16.10.193/29

in-band-ip6:               fe80::640e:94ff:fef4:2dd5/64

in-band-ip6-assign:        autoconf

gateway-ip:                10.13.2.1

dns-ip:                    10.135.2.3

dns-secondary-ip:          10.20.4.1

domain-name:               pluribus.networks.com

ntp-server:                0.ubuntu.pool.ntp.org

ntp-secondary-server:      1.ubuntu.pool.ntp.org

timezone:                  America/Los_Angeles

date:                      2020-09-28,20:26:52

hostid:                    184557812

location-id:               29

enable-host-ports:         yes

banner:                    * Welcome to Pluribus Networks Inc. Netvisor(R). This is a monitored system.   *

device-id:                 883QY03

ntp:                       on

banner:                    *                ACCESS RESTRICTED TO AUTHORIZED USERS ONLY                    *

banner:                    * By using the Netvisor(R) CLI,you agree to the terms of the Pluribus Networks *

banner:                    * End User License Agreement (EULA). The EULA can be accessed via              *

banner:                    * http://www.pluribusnetworks.com/eula or by using the command "eula-show"     *

CLI (network-admin@corvus-ring-1) > 


Usage Notes:


Timezone and Date are the same across all nodes (highly recommend).

On occasion customers use dummy Gateway, DNS, NTP settings.

mgmt-link-* (state/speed) is used to check basic connectivity issues.


Arista NetVisor UNUM: Use the Topology Dashboard to review the switch setup.


Switch Status Show


Use the switch-status-show command to obtain switch operational values and status:


The generated output is fabric scope.


CLI (network-admin@corvus-ring-1) > switch-status-show

switch        name                value  units     state 

------------- ------------------- ------ --------- ----- 

corvus-ring-1 FAN1                13239  rpm       ok    

corvus-ring-1 FAN2                13151  rpm       ok    

corvus-ring-1 FAN3                13239  rpm       ok    

corvus-ring-1 FAN4                13195  rpm       ok    

corvus-ring-1 PSU1 (FAN5)         16480  rpm       ok    

corvus-ring-1 PSU2 (FAN6)                rpm       fault 

corvus-ring-1 Switch Right Temp   23     degrees-C ok    

corvus-ring-1 Switch Left Temp    29     degrees-C ok    

corvus-ring-1 Qsfp Temp           25     degrees-C ok    

corvus-ring-1 Mac Temp            33     degrees-C ok    

corvus-ring-1 CPU Temp            26     degrees-C ok    

corvus-ring-1 FanTray Temp        25     degrees-C ok    

corvus-ring-1 LF Temp             25     degrees-C ok    

corvus-ring-1 PSU 1 Temp          21     degrees-C ok    

corvus-ring-1 PSU 2 Temp                 degrees-C fault 

corvus-ring-2 FAN1                11045  rpm       ok    

corvus-ring-2 FAN2                11014  rpm       ok    

corvus-ring-2 FAN3                11076  rpm       ok    

corvus-ring-2 FAN4                11014  rpm       ok    

corvus-ring-2 PSU1 (FAN5)         14608  rpm       ok    

corvus-ring-2 PSU2 (FAN6)                rpm       fault 

corvus-ring-2 Switch Right Temp   23     degrees-C ok    

corvus-ring-2 Switch Left Temp    28     degrees-C ok    

corvus-ring-2 Qsfp Temp           24     degrees-C ok    

corvus-ring-2 Mac Temp            32     degrees-C ok    

corvus-ring-2 CPU Temp            27     degrees-C ok    

corvus-ring-2 FanTray Temp        25     degrees-C ok    

corvus-ring-2 LF Temp             25     degrees-C ok    

corvus-ring-2 PSU 1 Temp          22     degrees-C ok    

corvus-ring-2 PSU 2 Temp                 degrees-C fault 

pavo-ring-7   FAN1                12850  rpm       ok    

pavo-ring-7   FAN2                12483  rpm       ok    

pavo-ring-7   FAN3                12934  rpm       ok    

pavo-ring-7   SFPP Temp           23     degrees-C ok    

pavo-ring-7   QSFP Temp           23     degrees-C ok    

pavo-ring-7   Switch Bottom Temp  27     degrees-C ok    

pavo-ring-7   Rear Panel Temp     26     degrees-C ok    

pavo-ring-7   Switch Top Temp     31     degrees-C ok    

pavo-ring-7   CPU Temp            30     degrees-C ok    

pavo-ring-8   FAN1                12061  rpm       ok    

pavo-ring-8   FAN2                13195  rpm       ok    

pavo-ring-8   FAN3                12136  rpm       ok    

pavo-ring-8   SFPP Temp           21     degrees-C ok    

pavo-ring-8   QSFP Temp           22     degrees-C ok    

pavo-ring-8   Switch Bottom Temp  26     degrees-C ok    

pavo-ring-8   Rear Panel Temp     26     degrees-C ok    

pavo-ring-8   Switch Top Temp     31     degrees-C ok    

pavo-ring-8   CPU Temp            28     degrees-C ok    

pavo-ring-12  FAN1                12404  rpm       ok    

pavo-ring-12  FAN2                12562  rpm       ok    

pavo-ring-12  FAN3                12404  rpm       ok    

switch        name                value  units     state 

------------- ------------------- ------ --------- ----- 

pavo-ring-12  SFPP Temp           21     degrees-C ok    

pavo-ring-12  QSFP Temp           22     degrees-C ok    

pavo-ring-12  Switch Bottom Temp  27     degrees-C ok    

pavo-ring-12  Rear Panel Temp     26     degrees-C ok    

pavo-ring-12  Switch Top Temp     30     degrees-C ok    

pavo-ring-12  CPU Temp            29     degrees-C ok    

pavo-ring-9   FAN1                12684  rpm       ok    

pavo-ring-9   FAN2                12934  rpm       ok    

pavo-ring-9   FAN3                12562  rpm       ok    

pavo-ring-9   SFPP Temp           24     degrees-C ok    

pavo-ring-9   QSFP Temp           23     degrees-C ok    

pavo-ring-9   Switch Bottom Temp  27     degrees-C ok    

pavo-ring-9   Rear Panel Temp     25     degrees-C ok    

pavo-ring-9   Switch Top Temp     32     degrees-C ok    

pavo-ring-9   CPU Temp            30     degrees-C ok    

pavo-ring-11  FAN1                12061  rpm       ok    

pavo-ring-11  FAN2                12249  rpm       ok    

pavo-ring-11  FAN3                12562  rpm       ok    

pavo-ring-11  SFPP Temp           23     degrees-C ok    

pavo-ring-11  QSFP Temp           23     degrees-C ok    

pavo-ring-11  Switch Bottom Temp  27     degrees-C ok    

pavo-ring-11  Rear Panel Temp     26     degrees-C ok    

pavo-ring-11  Switch Top Temp     32     degrees-C ok    

pavo-ring-11  CPU Temp            30     degrees-C ok    

pavo-ring-2   FAN1                13797  rpm       ok    

pavo-ring-2   FAN2                13797  rpm       ok    

pavo-ring-2   FAN3                13845  rpm       ok    

pavo-ring-2   SFPP Temp           29     degrees-C ok    

pavo-ring-2   QSFP Temp           30     degrees-C ok    

pavo-ring-2   Switch Bottom Temp  33     degrees-C ok    

pavo-ring-2   Rear Panel Temp     33     degrees-C ok    

pavo-ring-2   Switch Top Temp     37     degrees-C ok    

pavo-ring-2   CPU Temp            36     degrees-C ok    

pavo-ring-1   FAN1                13894  rpm       ok    

pavo-ring-1   FAN2                14043  rpm       ok    

pavo-ring-1   FAN3                13894  rpm       ok    

pavo-ring-1   SFPP Temp           27     degrees-C ok    

pavo-ring-1   QSFP Temp           29     degrees-C ok    

pavo-ring-1   Switch Bottom Temp  32     degrees-C ok    

pavo-ring-1   Rear Panel Temp     32     degrees-C ok    

pavo-ring-1   Switch Top Temp     36     degrees-C ok    

pavo-ring-1   CPU Temp            35     degrees-C ok    

pavo-ring-6   FAN1                12603  rpm       ok    

pavo-ring-6   FAN2                12365  rpm       ok    

pavo-ring-6   FAN3                12643  rpm       ok    

pavo-ring-6   SFPP Temp           20     degrees-C ok    

pavo-ring-6   QSFP Temp           22     degrees-C ok    

pavo-ring-6   Switch Bottom Temp  26     degrees-C ok    

pavo-ring-6   Rear Panel Temp     26     degrees-C ok    

pavo-ring-6   Switch Top Temp     30     degrees-C ok    

pavo-ring-6   CPU Temp            28     degrees-C ok    

switch        name                value  units     state 

------------- ------------------- ------ --------- ----- 

pavo-ring-5   FAN1                12850  rpm       ok    

pavo-ring-5   FAN2                12404  rpm       ok    

pavo-ring-5   FAN3                13195  rpm       ok    

pavo-ring-5   SFPP Temp           23     degrees-C ok    

pavo-ring-5   QSFP Temp           23     degrees-C ok    

pavo-ring-5   Switch Bottom Temp  27     degrees-C ok    

pavo-ring-5   Rear Panel Temp     25     degrees-C ok    

pavo-ring-5   Switch Top Temp     31     degrees-C ok    

pavo-ring-5   CPU Temp            30     degrees-C ok    

delph-ring-1  FAN1                11045  rpm       ok    

delph-ring-1  FAN2                10983  rpm       ok    

delph-ring-1  FAN3                11045  rpm       ok    

delph-ring-1  FAN4                11045  rpm       ok    

delph-ring-1  PSU1 (FAN5)         14608  rpm       ok    

delph-ring-1  PSU2 (FAN6)                rpm       fault 

delph-ring-1  Switch Temp         29     degrees-C ok    

delph-ring-1  Left Front Temp     25     degrees-C ok    

delph-ring-1  Right Front Temp    26     degrees-C ok    

delph-ring-1  QSFP Temp           26     degrees-C ok    

delph-ring-1  FanTray Temp        24     degrees-C ok    

delph-ring-1  PSU 1 Temp          25     degrees-C ok    

delph-ring-1  PSU 2 Temp                 degrees-C fault 

delph-ring-4  FAN1                10983  rpm       ok    

delph-ring-4  FAN2                11014  rpm       ok    

delph-ring-4  FAN3                11014  rpm       ok    

delph-ring-4  FAN4                11014  rpm       ok    

delph-ring-4  PSU1 (FAN5)         14640  rpm       ok    

delph-ring-4  PSU2 (FAN6)                rpm       fault 

delph-ring-4  Switch Temp         24     degrees-C ok    

delph-ring-4  Left Front Temp     24     degrees-C ok    

delph-ring-4  Right Front Temp    21     degrees-C ok    

delph-ring-4  QSFP Temp           21     degrees-C ok    

delph-ring-4  FanTray Temp        21     degrees-C ok    

delph-ring-4  PSU 1 Temp          20     degrees-C ok    

delph-ring-4  PSU 2 Temp                 degrees-C fault 

delph-ring-3  FAN1                11014  rpm       ok    

delph-ring-3  FAN2                10983  rpm       ok    

delph-ring-3  FAN3                11014  rpm       ok    

delph-ring-3  FAN4                11014  rpm       ok    

delph-ring-3  PSU1 (FAN5)         14368  rpm       ok    

delph-ring-3  PSU2 (FAN6)                rpm       fault 

delph-ring-3  Switch Temp         25     degrees-C ok    

delph-ring-3  Left Front Temp     25     degrees-C ok    

delph-ring-3  Right Front Temp    21     degrees-C ok    

delph-ring-3  QSFP Temp           21     degrees-C ok    

delph-ring-3  FanTray Temp        23     degrees-C ok    

delph-ring-3  PSU 1 Temp          21     degrees-C ok    

delph-ring-3  PSU 2 Temp                 degrees-C fault 

scorp-ring-2  FAN1                11045  rpm       ok    

scorp-ring-2  FAN2                10983  rpm       ok    

scorp-ring-2  FAN3                11014  rpm       ok    

switch        name                value  units     state 

------------- ------------------- ------ --------- ----- 

scorp-ring-2  FAN4                11014  rpm       ok    

scorp-ring-2  PSU1 (FAN5)         11664  rpm       ok    

scorp-ring-2  PSU2 (FAN6)                rpm       fault 

scorp-ring-2  Switch Temp         31     degrees-C ok    

scorp-ring-2  Left Front Temp     30     degrees-C ok    

scorp-ring-2  Right Front Temp    30     degrees-C ok    

scorp-ring-2  CPU Temp            26     degrees-C ok    

scorp-ring-2  QSFP Temp           31     degrees-C ok    

scorp-ring-2  FanTray Temp        25     degrees-C ok    

scorp-ring-2  PSU 1 Temp          27     degrees-C ok    

scorp-ring-2  PSU 2 Temp                 degrees-C fault 

delph-ring-2  FAN1                11014  rpm       ok    

delph-ring-2  FAN2                10983  rpm       ok    

delph-ring-2  FAN3                10983  rpm       ok    

delph-ring-2  FAN4                10983  rpm       ok    

delph-ring-2  PSU1 (FAN5)         14688  rpm       ok    

delph-ring-2  PSU2 (FAN6)                rpm       fault 

delph-ring-2  Switch Temp         28     degrees-C ok    

delph-ring-2  Left Front Temp     25     degrees-C ok    

delph-ring-2  Right Front Temp    25     degrees-C ok    

delph-ring-2  QSFP Temp           23     degrees-C ok    

delph-ring-2  FanTray Temp        23     degrees-C ok    

delph-ring-2  PSU 1 Temp          24     degrees-C ok    

delph-ring-2  PSU 2 Temp                 degrees-C fault 

pavo-ring-3   FAN1                12643  rpm       ok    

pavo-ring-3   FAN2                11951  rpm       ok    

pavo-ring-3   FAN3                12977  rpm       ok    

pavo-ring-3   SFPP Temp           24     degrees-C ok    

pavo-ring-3   QSFP Temp           23     degrees-C ok    

pavo-ring-3   Switch Bottom Temp  27     degrees-C ok    

pavo-ring-3   Rear Panel Temp     26     degrees-C ok    

pavo-ring-3   Switch Top Temp     31     degrees-C ok    

pavo-ring-3   CPU Temp            30     degrees-C ok    

hydra-ring-2  FAN1                10031  rpm       ok    

hydra-ring-2  FAN2                10240  rpm       ok    

hydra-ring-2  FAN3                10160  rpm       ok    

hydra-ring-2  FAN4                10186  rpm       ok    

hydra-ring-2  FAN5                7975   rpm       ok    

hydra-ring-2  FAN6                7992   rpm       ok    

hydra-ring-2  FAN7                7975   rpm       ok    

hydra-ring-2  FAN8                8008   rpm       ok    

hydra-ring-2  PSU1 (FAN9)                rpm       fault 

hydra-ring-2  PSU2 (FAN10)        11632  rpm       ok    

hydra-ring-2  Switch Right Temp   33     degrees-C ok    

hydra-ring-2  Switch Left Temp    37     degrees-C ok    

hydra-ring-2  Qsfp Temp           37     degrees-C ok    

hydra-ring-2  Mac Temp            36     degrees-C ok    

hydra-ring-2  CPU Temp            27     degrees-C ok    

hydra-ring-2  FanTray Temp        27     degrees-C ok    

hydra-ring-2  LF Temp             33     degrees-C ok    

hydra-ring-2  PSU 1 Temp                 degrees-C fault 

switch        name                value  units     state 

------------- ------------------- ------ --------- ----- 

hydra-ring-2  PSU 2 Temp          27     degrees-C ok    

scorp-ring-1  FAN1                13195  rpm       ok    

scorp-ring-1  FAN2                13284  rpm       ok    

scorp-ring-1  FAN3                13239  rpm       ok    

scorp-ring-1  FAN4                13239  rpm       ok    

scorp-ring-1  PSU1 (FAN5)         14032  rpm       ok    

scorp-ring-1  PSU2 (FAN6)                rpm       fault 

scorp-ring-1  Switch Temp         32     degrees-C ok    

scorp-ring-1  Left Front Temp     30     degrees-C ok    

scorp-ring-1  Right Front Temp    31     degrees-C ok    

scorp-ring-1  CPU Temp            27     degrees-C ok    

scorp-ring-1  QSFP Temp           32     degrees-C ok    

scorp-ring-1  FanTray Temp        28     degrees-C ok    

scorp-ring-1  PSU 1 Temp          28     degrees-C ok    

scorp-ring-1  PSU 2 Temp                 degrees-C fault 

pavo-ring-4   FAN1                11951  rpm       ok    

pavo-ring-4   FAN2                13284  rpm       ok    

pavo-ring-4   FAN3                12249  rpm       ok    

pavo-ring-4   SFPP Temp           20     degrees-C ok    

pavo-ring-4   QSFP Temp           22     degrees-C ok    

pavo-ring-4   Switch Bottom Temp  26     degrees-C ok    

pavo-ring-4   Rear Panel Temp     26     degrees-C ok    

pavo-ring-4   Switch Top Temp     31     degrees-C ok    

pavo-ring-4   CPU Temp            28     degrees-C ok    

hydra-ring-1  FAN1                10160  rpm       ok    

hydra-ring-1  FAN2                10005  rpm       ok    

hydra-ring-1  FAN3                10266  rpm       ok    

hydra-ring-1  FAN4                10056  rpm       ok    

hydra-ring-1  FAN5                8008   rpm       ok    

hydra-ring-1  FAN6                7992   rpm       ok    

hydra-ring-1  FAN7                7975   rpm       ok    

hydra-ring-1  FAN8                8008   rpm       ok    

hydra-ring-1  PSU1 (FAN9)                rpm       fault 

hydra-ring-1  PSU2 (FAN10)        11632  rpm       ok    

hydra-ring-1  Switch Right Temp   32     degrees-C ok    

hydra-ring-1  Switch Left Temp    36     degrees-C ok    

hydra-ring-1  Qsfp Temp           38     degrees-C ok    

hydra-ring-1  Mac Temp            37     degrees-C ok    

hydra-ring-1  CPU Temp            28     degrees-C ok    

hydra-ring-1  FanTray Temp        27     degrees-C ok    

hydra-ring-1  LF Temp             33     degrees-C ok    

hydra-ring-1  PSU 1 Temp                 degrees-C fault 

hydra-ring-1  PSU 2 Temp          28     degrees-C ok    

pyxis-ring-2  FAN1 (Fan #1 Rear)  7680   rpm       ok    

pyxis-ring-2  FAN2 (Fan #1 Front) 8400   rpm       ok    

pyxis-ring-2  FAN3 (Fan #2 Rear)  7680   rpm       ok    

pyxis-ring-2  FAN4 (Fan #2 Front) 8520   rpm       ok    

pyxis-ring-2  FAN5 (Fan #3 Rear)  7680   rpm       ok    

pyxis-ring-2  FAN6 (Fan #3 Front) 8520   rpm       ok    

pyxis-ring-2  FAN7 (Fan #4 Rear)  7680   rpm       ok    

pyxis-ring-2  FAN8 (Fan #4 Front) 8520   rpm       ok    

switch        name                value  units     state 

------------- ------------------- ------ --------- ----- 

pyxis-ring-2  FAN9 (PSU #1)       7440   rpm       ok    

pyxis-ring-2  FAN10 (PSU #2)             rpm       fault 

pyxis-ring-2  PT Mid Temp         24     degrees-C ok    

pyxis-ring-2  NPU Near Temp       28     degrees-C ok    

pyxis-ring-2  PT Left Temp        23     degrees-C ok    

pyxis-ring-2  PT Right Temp       24     degrees-C ok    

pyxis-ring-2  ILET AF Temp        23     degrees-C ok    

pyxis-ring-2  CPU Temp            28     degrees-C ok    

pyxis-ring-2  PSU1 AF Temp        24     degrees-C ok    

pyxis-ring-2  PSU2 AF Temp        24     degrees-C ok    

pyxis-ring-2  PSU1 Temp           33     degrees-C ok    

pyxis-ring-2  PSU2 Temp                  degrees-C fault 

pyxis-ring-2  PSU1 VIn            210.10 volts     ok    

pyxis-ring-2  PSU1 VOut           12.40  volts     ok    

pyxis-ring-2  PSU2 VIn                   volts     fault 

pyxis-ring-2  PSU2 VOut                  volts     fault 

pyxis-ring-2  INTER 5.0V          4.90   volts     ok    

pyxis-ring-2  INTER 3.3V          3.20   volts     ok    

pyxis-ring-2  FPGA 1.0V           0.98   volts     ok    

pyxis-ring-2  FPGA 1.2V           1.18   volts     ok    

pyxis-ring-2  FPGA 1.8V           1.78   volts     ok    

pyxis-ring-2  FPGA 3.3V           3.20   volts     ok    

pyxis-ring-2  BMC 2.5V            2.40   volts     ok    

pyxis-ring-2  BMC 1.15V           1.14   volts     ok    

pyxis-ring-2  BMC 1.2V            1.20   volts     ok    

pyxis-ring-2  SWITCH 6.8V         6.80   volts     ok    

pyxis-ring-2  SWITCH 3.3V         3.20   volts     ok    

pyxis-ring-2  SWITCH 1.8V         1.76   volts     ok    

pyxis-ring-2  USB 5.0V            4.90   volts     ok    

pyxis-ring-2  NPU 1.2V            1.17   volts     ok    

pyxis-ring-2  NPU VDDCORE         0.83   volts     ok    

pyxis-ring-2  NPU VDDANLG         0.79   volts     ok    

pyxis-ring-3  FAN1 (Fan #1 Rear)  7680   rpm       ok    

pyxis-ring-3  FAN2 (Fan #1 Front) 8520   rpm       ok    

pyxis-ring-3  FAN3 (Fan #2 Rear)  7800   rpm       ok    

pyxis-ring-3  FAN4 (Fan #2 Front) 8400   rpm       ok    

pyxis-ring-3  FAN5 (Fan #3 Rear)  7800   rpm       ok    

pyxis-ring-3  FAN6 (Fan #3 Front) 8520   rpm       ok    

pyxis-ring-3  FAN7 (Fan #4 Rear)  7800   rpm       ok    

pyxis-ring-3  FAN8 (Fan #4 Front) 8760   rpm       ok    

pyxis-ring-3  FAN9 (PSU #1)       7440   rpm       ok    

pyxis-ring-3  FAN10 (PSU #2)             rpm       fault 

pyxis-ring-3  PT Mid Temp         24     degrees-C ok    

pyxis-ring-3  NPU Near Temp       28     degrees-C ok    

pyxis-ring-3  PT Left Temp        23     degrees-C ok    

pyxis-ring-3  PT Right Temp       23     degrees-C ok    

pyxis-ring-3  ILET AF Temp        23     degrees-C ok    

pyxis-ring-3  CPU Temp            28     degrees-C ok    

pyxis-ring-3  PSU1 AF Temp        24     degrees-C ok    

pyxis-ring-3  PSU2 AF Temp        25     degrees-C ok    

pyxis-ring-3  PSU1 Temp           32     degrees-C ok    

switch        name                value  units     state 

------------- ------------------- ------ --------- ----- 

pyxis-ring-3  PSU2 Temp                  degrees-C fault 

pyxis-ring-3  PSU1 VIn            210.10 volts     ok    

pyxis-ring-3  PSU1 VOut           12.50  volts     ok    

pyxis-ring-3  PSU2 VIn                   volts     fault 

pyxis-ring-3  PSU2 VOut                  volts     fault 

pyxis-ring-3  INTER 5.0V          4.90   volts     ok    

pyxis-ring-3  INTER 3.3V          3.20   volts     ok    

pyxis-ring-3  FPGA 1.0V           0.98   volts     ok    

pyxis-ring-3  FPGA 1.2V           1.18   volts     ok    

pyxis-ring-3  FPGA 1.8V           1.78   volts     ok    

pyxis-ring-3  FPGA 3.3V           3.20   volts     ok    

pyxis-ring-3  BMC 2.5V            2.40   volts     ok    

pyxis-ring-3  BMC 1.15V           1.15   volts     ok    

pyxis-ring-3  BMC 1.2V            1.20   volts     ok    

pyxis-ring-3  SWITCH 6.8V         6.90   volts     ok    

pyxis-ring-3  SWITCH 3.3V         3.20   volts     ok    

pyxis-ring-3  SWITCH 1.8V         1.77   volts     ok    

pyxis-ring-3  USB 5.0V            4.90   volts     ok    

pyxis-ring-3  NPU 1.2V            1.18   volts     ok    

pyxis-ring-3  NPU VDDCORE         0.83   volts     ok    

pyxis-ring-3  NPU VDDANLG         0.79   volts     ok    

pyxis-ring-1  FAN1 (Fan #1 Rear)  7680   rpm       ok    

pyxis-ring-1  FAN2 (Fan #1 Front) 8520   rpm       ok    

pyxis-ring-1  FAN3 (Fan #2 Rear)  7680   rpm       ok    

pyxis-ring-1  FAN4 (Fan #2 Front) 8520   rpm       ok    

pyxis-ring-1  FAN5 (Fan #3 Rear)  7680   rpm       ok    

pyxis-ring-1  FAN6 (Fan #3 Front) 8520   rpm       ok    

pyxis-ring-1  FAN7 (Fan #4 Rear)  7680   rpm       ok    

pyxis-ring-1  FAN8 (Fan #4 Front) 8400   rpm       ok    

pyxis-ring-1  FAN9 (PSU #1)       7560   rpm       ok    

pyxis-ring-1  FAN10 (PSU #2)             rpm       fault 

pyxis-ring-1  PT Mid Temp         23     degrees-C ok    

pyxis-ring-1  NPU Near Temp       28     degrees-C ok    

pyxis-ring-1  PT Left Temp        23     degrees-C ok    

pyxis-ring-1  PT Right Temp       23     degrees-C ok    

pyxis-ring-1  ILET AF Temp        23     degrees-C ok    

pyxis-ring-1  CPU Temp            28     degrees-C ok    

pyxis-ring-1  PSU1 AF Temp        24     degrees-C ok    

pyxis-ring-1  PSU2 AF Temp        25     degrees-C ok    

pyxis-ring-1  PSU1 Temp           32     degrees-C ok    

pyxis-ring-1  PSU2 Temp                  degrees-C fault 

pyxis-ring-1  PSU1 VIn            210.10 volts     ok    

pyxis-ring-1  PSU1 VOut           12.50  volts     ok    

pyxis-ring-1  PSU2 VIn                   volts     fault 

pyxis-ring-1  PSU2 VOut                  volts     fault 

pyxis-ring-1  INTER 5.0V          4.90   volts     ok    

pyxis-ring-1  INTER 3.3V          3.20   volts     ok    

pyxis-ring-1  FPGA 1.0V           0.99   volts     ok    

pyxis-ring-1  FPGA 1.2V           1.19   volts     ok    

pyxis-ring-1  FPGA 1.8V           1.78   volts     ok    

pyxis-ring-1  FPGA 3.3V           3.20   volts     ok    

switch        name                value  units     state 

------------- ------------------- ------ --------- ----- 

pyxis-ring-1  BMC 2.5V            2.40   volts     ok    

pyxis-ring-1  BMC 1.15V           1.14   volts     ok    

pyxis-ring-1  BMC 1.2V            1.19   volts     ok    

pyxis-ring-1  SWITCH 6.8V         7.00   volts     ok    

pyxis-ring-1  SWITCH 3.3V         3.20   volts     ok    

pyxis-ring-1  SWITCH 1.8V         1.77   volts     ok    

pyxis-ring-1  USB 5.0V            4.90   volts     ok    

pyxis-ring-1  NPU 1.2V            1.18   volts     ok    

pyxis-ring-1  NPU VDDCORE         0.83   volts     ok    

pyxis-ring-1  NPU VDDANLG         0.79   volts     ok    


Verify Management Services


Access to services through the management interface can be enabled/disabled as needed for your environment. However, a misconfigured service may appear as something has failed.


Confirm correctly configured management interface services with the command: admin-service-show


CLI (network-admin@udev-leo1) > admin-service-show

switch     if   ssh nfs web web-ssl web-ssl-port web-port vrrp snmp net-api icmp 

---------- ---- --- --- --- ------- ------------ -------- ---- ---- ------- ---- 

udev-leo1  mgmt on  off on  on      443          80       off  on   on      on   

udev-leo1  data on  off on  off     443          80       off  on   on      on   

udev-leo-4 mgmt on  off on  on      443          80       off  on   on      on   

udev-leo-4 data on  off on  off     443          80       off  on   on      on   

udev-leo-3 mgmt on  off on  on      443          80       off  on   on      on   

udev-leo-3 data on  off on  off     443          80       off  on   on      on   


Arista NetVisor UNUM: Use the Manage Admin Service Dashboard to review and verify management services.


Validate the Hardware


It is usually a good idea to eliminate hardware problems first. 


Confirm the hardware is in good health using the following commands and the components are functioning correctly with the command: switch-info-show


CLI (network-admin@udev-leo1*) > switch-info-show

switch:                   udev-leo1

model:                    E68-M-ONVL

chassis-serial:           1617AT9000017

cpu1-type:                Intel(R) Xeon(R) CPU E3-1265L V2 @ 2.50GHz

cpu2-type:                Intel(R) Xeon(R) CPU E3-1265L V2 @ 2.50GHz

cpu3-type:                Intel(R) Xeon(R) CPU E3-1265L V2 @ 2.50GHz

cpu4-type:                Intel(R) Xeon(R) CPU E3-1265L V2 @ 2.50GHz

system-mem:               15.7G

switch-device:            OK

fan1-status:              ok

fan2-status:              ok

fan3-status:              ok

fan4-status:              ok

fan5-status:              ok

fan6-status:              ok

fan7-status:              ok

fan8-status:              ok

ps1-status:               na

ps2-status:               ok

disk-model:               SQF-S25M8-128G-S8C                      

disk-firmware:            S8FM06A7

disk-size:                119G

disk-type:                Solid State Disk, TRIM Supported

bios-vendor:              American Megatrends Inc./Advantech Corp.

bios-version:             9012V026

netvisor-cert-valid-from: Apr 20 07:00:00 2016 GMT

netvisor-cert-valid-till: Apr 21 06:59:59 2036 GMT


When using the tech-support command data collected in local scope only.


CLI (network-admin@corvus-ring-1) > switch-info-show

switch:                   corvus-ring-1

model:                    S4128T-ON

chassis-serial:           1839PN8500071

cpu1-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

cpu2-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

system-mem:               3.56G

switch-device:            OK

fan1-status:              OK

fan2-status:              OK

fan3-status:              OK

fan4-status:              OK

fan5-status:              OK

fan6-status:              FAULT

ps1-status:               OK

ps2-status:               FAULT

disk-model:               InnoDisk Corp. - mSATA 3IE3             

disk-firmware:            S16425c1

disk-size:                14.9G

disk-type:                Solid State Disk, TRIM Supported

bios-vendor:              American Megatrends Inc.

bios-version:             5.6.5

netvisor-cert-valid-from: Sep 25 04:00:00 2018 GMT

netvisor-cert-valid-till: Sep 26 03:59:59 2038 GMT

switch:                   corvus-ring-2

model:                    S4128T-ON

chassis-serial:           1839PN8500064

cpu1-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

cpu2-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

system-mem:               3.56G

switch-device:            OK

fan1-status:              OK

fan2-status:              OK

fan3-status:              OK

fan4-status:              OK

fan5-status:              OK

fan6-status:              FAULT

ps1-status:               OK

ps2-status:               FAULT

disk-model:               InnoDisk Corp. - mSATA 3IE3             

disk-firmware:            S16425c1

disk-size:                14.9G

disk-type:                Solid State Disk, TRIM Supported

bios-vendor:              American Megatrends Inc.

bios-version:             5.6.5

netvisor-cert-valid-from: Sep 25 04:00:00 2018 GMT

netvisor-cert-valid-till: Sep 26 03:59:59 2038 GMT

switch:                   pavo-ring-7

model:                    S4112F-ON

chassis-serial:           1941ST9100010

cpu1-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

cpu2-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

system-mem:               3.56G

switch-device:            OK

fan1-status:              OK

fan2-status:              OK

fan3-status:              OK

ps1-status:               OK

ps2-status:               FAULT

disk-model:               M.2 (S42) 3IE3                          

disk-firmware:            S17411c1

disk-size:                14.9G

disk-type:                Solid State Disk, TRIM Supported

bios-vendor:              American Megatrends Inc.

bios-version:             5.6.5

netvisor-cert-valid-from: Oct  7 07:00:00 2019 GMT

netvisor-cert-valid-till: Oct  8 06:59:59 2039 GMT

switch:                   pavo-ring-8

model:                    S4112F-ON

chassis-serial:           1941ST9100102

cpu1-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

cpu2-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

system-mem:               3.56G

switch-device:            OK

fan1-status:              OK

fan2-status:              OK

fan3-status:              OK

ps1-status:               OK

ps2-status:               FAULT

disk-model:               M.2 (S42) 3IE3                          

disk-firmware:            S17411c1

disk-size:                14.9G

disk-type:                Solid State Disk, TRIM Supported

bios-vendor:              American Megatrends Inc.

bios-version:             5.6.5

netvisor-cert-valid-from: Oct  7 07:00:00 2019 GMT

netvisor-cert-valid-till: Oct  8 06:59:59 2039 GMT

switch:                   pavo-ring-12

model:                    S4112F-ON

chassis-serial:           1941ST9100041

cpu1-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

cpu2-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

system-mem:               3.56G

switch-device:            OK

fan1-status:              OK

fan2-status:              OK

fan3-status:              OK

ps1-status:               OK

ps2-status:               FAULT

disk-model:               M.2 (S42) 3IE3                          

disk-firmware:            S17411c1

disk-size:                14.9G

disk-type:                Solid State Disk, TRIM Supported

bios-vendor:              American Megatrends Inc.

bios-version:             5.6.5

netvisor-cert-valid-from: Oct  7 07:00:00 2019 GMT

netvisor-cert-valid-till: Oct  8 06:59:59 2039 GMT

switch:                   pavo-ring-9

model:                    S4112F-ON

chassis-serial:           1941ST9100058

cpu1-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

cpu2-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

system-mem:               3.56G

switch-device:            OK

fan1-status:              OK

fan2-status:              OK

fan3-status:              OK

ps1-status:               OK

ps2-status:               FAULT

disk-model:               M.2 (S42) 3IE3                          

disk-firmware:            S17411c1

disk-size:                14.9G

disk-type:                Solid State Disk, TRIM Supported

bios-vendor:              American Megatrends Inc.

bios-version:             5.6.5

netvisor-cert-valid-from: Oct  7 07:00:00 2019 GMT

netvisor-cert-valid-till: Oct  8 06:59:59 2039 GMT

switch:                   pavo-ring-11

model:                    S4112F-ON

chassis-serial:           1941ST9100034

cpu1-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

cpu2-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

system-mem:               3.56G

switch-device:            OK

fan1-status:              OK

fan2-status:              OK

fan3-status:              OK

ps1-status:               OK

ps2-status:               FAULT

disk-model:               M.2 (S42) 3IE3                          

disk-firmware:            S17411c1

disk-size:                14.9G

disk-type:                Solid State Disk, TRIM Supported

bios-vendor:              American Megatrends Inc.

bios-version:             5.6.5

netvisor-cert-valid-from: Oct  7 07:00:00 2019 GMT

netvisor-cert-valid-till: Oct  8 06:59:59 2039 GMT

switch:                   pavo-ring-2

model:                    S4112F-ON

chassis-serial:           1936ST9100030

cpu1-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

cpu2-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

system-mem:               3.56G

switch-device:            OK

fan1-status:              OK

fan2-status:              OK

fan3-status:              OK

ps1-status:               OK

ps2-status:               FAULT

disk-model:               M.2 (S42) 3IE3                          

disk-firmware:            S17411c1

disk-size:                14.9G

disk-type:                Solid State Disk, TRIM Supported

bios-vendor:              American Megatrends Inc.

bios-version:             5.6.5

netvisor-cert-valid-from: Sep  2 07:00:00 2019 GMT

netvisor-cert-valid-till: Sep  3 06:59:59 2039 GMT

switch:                   pavo-ring-1

model:                    S4112F-ON

chassis-serial:           1936ST9100023

cpu1-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

cpu2-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

system-mem:               3.56G

switch-device:            OK

fan1-status:              OK

fan2-status:              OK

fan3-status:              OK

ps1-status:               OK

ps2-status:               FAULT

disk-model:               M.2 (S42) 3IE3                          

disk-firmware:            S17411c1

disk-size:                14.9G

disk-type:                Solid State Disk, TRIM Supported

bios-vendor:              American Megatrends Inc.

bios-version:             5.6.5

netvisor-cert-valid-from: Sep  2 07:00:00 2019 GMT

netvisor-cert-valid-till: Sep  3 06:59:59 2039 GMT

switch:                   pavo-ring-6

model:                    S4112F-ON

chassis-serial:           1941ST9100089

cpu1-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

cpu2-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

system-mem:               3.56G

switch-device:            OK

fan1-status:              OK

fan2-status:              OK

fan3-status:              OK

ps1-status:               OK

ps2-status:               FAULT

disk-model:               M.2 (S42) 3IE3                          

disk-firmware:            S17411c1

disk-size:                14.9G

disk-type:                Solid State Disk, TRIM Supported

bios-vendor:              American Megatrends Inc.

bios-version:             5.6.5

netvisor-cert-valid-from: Oct  7 07:00:00 2019 GMT

netvisor-cert-valid-till: Oct  8 06:59:59 2039 GMT

switch:                   pavo-ring-5

model:                    S4112F-ON

chassis-serial:           1941ST9100072

cpu1-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

cpu2-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

system-mem:               3.56G

switch-device:            OK

fan1-status:              OK

fan2-status:              OK

fan3-status:              OK

ps1-status:               OK

ps2-status:               FAULT

disk-model:               M.2 (S42) 3IE3                          

disk-firmware:            S17411c1

disk-size:                14.9G

disk-type:                Solid State Disk, TRIM Supported

bios-vendor:              American Megatrends Inc.

bios-version:             5.6.5

netvisor-cert-valid-from: Oct  7 07:00:00 2019 GMT

netvisor-cert-valid-till: Oct  8 06:59:59 2039 GMT

switch:                   delph-ring-1

model:                    S4128F-ON

chassis-serial:           1936ST9100016

cpu1-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

cpu2-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

system-mem:               3.56G

switch-device:            OK

fan1-status:              OK

fan2-status:              OK

fan3-status:              OK

fan4-status:              OK

fan5-status:              OK

fan6-status:              FAULT

ps1-status:               OK

ps2-status:               FAULT

disk-model:               InnoDisk Corp. - mSATA 3IE3             

disk-firmware:            S16425c1

disk-size:                14.9G

disk-type:                Solid State Disk, TRIM Supported

bios-vendor:              American Megatrends Inc.

bios-version:             5.6.5

netvisor-cert-valid-from: Sep  2 07:00:00 2019 GMT

netvisor-cert-valid-till: Sep  3 06:59:59 2039 GMT

switch:                   delph-ring-4

model:                    S4128F-ON

chassis-serial:           1838ST9100037

cpu1-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

cpu2-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

system-mem:               3.56G

switch-device:            OK

fan1-status:              OK

fan2-status:              OK

fan3-status:              OK

fan4-status:              OK

fan5-status:              OK

fan6-status:              FAULT

ps1-status:               OK

ps2-status:               FAULT

disk-model:               InnoDisk Corp. - mSATA 3IE3             

disk-firmware:            S16425c1

disk-size:                14.9G

disk-type:                Solid State Disk, TRIM Supported

bios-vendor:              American Megatrends Inc.

bios-version:             5.6.5

netvisor-cert-valid-from: Sep 18 07:00:00 2018 GMT

netvisor-cert-valid-till: Sep 19 06:59:59 2038 GMT

switch:                   delph-ring-3

model:                    S4128F-ON

chassis-serial:           1827ST9100086

cpu1-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

cpu2-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

system-mem:               3.56G

switch-device:            OK

fan1-status:              OK

fan2-status:              OK

fan3-status:              OK

fan4-status:              OK

fan5-status:              OK

fan6-status:              FAULT

ps1-status:               OK

ps2-status:               FAULT

disk-model:               InnoDisk Corp. - mSATA 3IE3             

disk-firmware:            S16425c1

disk-size:                14.9G

disk-type:                Solid State Disk, TRIM Supported

bios-vendor:              American Megatrends Inc.

bios-version:             5.6.5

netvisor-cert-valid-from: Jul  6 07:00:00 2018 GMT

netvisor-cert-valid-till: Jul  7 06:59:59 2038 GMT

switch:                   scorp-ring-2

model:                    S4148-ON

chassis-serial:           1901ST9100021

cpu1-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

cpu2-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

system-mem:               3.56G

switch-device:            OK

fan1-status:              OK

fan2-status:              OK

fan3-status:              OK

fan4-status:              OK

fan5-status:              OK

fan6-status:              FAULT

ps1-status:               OK

ps2-status:               FAULT

disk-model:               InnoDisk Corp. - mSATA 3IE3             

disk-firmware:            S17411i 

disk-size:                14.9G

disk-type:                Solid State Disk, TRIM Supported

bios-vendor:              American Megatrends Inc.

bios-version:             5.6.5

netvisor-cert-valid-from: Jan  3 08:00:00 2019 GMT

netvisor-cert-valid-till: Jan  4 07:59:59 2039 GMT

switch:                   delph-ring-2

model:                    S4128F-ON

chassis-serial:           1936PN8500039

cpu1-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

cpu2-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

system-mem:               3.56G

switch-device:            OK

fan1-status:              OK

fan2-status:              OK

fan3-status:              OK

fan4-status:              OK

fan5-status:              OK

fan6-status:              FAULT

ps1-status:               OK

ps2-status:               FAULT

disk-model:               InnoDisk Corp. - mSATA 3IE3             

disk-firmware:            S16425c1

disk-size:                14.9G

disk-type:                Solid State Disk, TRIM Supported

bios-vendor:              American Megatrends Inc.

bios-version:             5.6.5

netvisor-cert-valid-from: Sep  2 04:00:00 2019 GMT

netvisor-cert-valid-till: Sep  3 03:59:59 2039 GMT

switch:                   pavo-ring-3

model:                    S4112F-ON

chassis-serial:           1941ST9100027

cpu1-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

cpu2-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

system-mem:               3.56G

switch-device:            OK

fan1-status:              OK

fan2-status:              OK

fan3-status:              OK

ps1-status:               OK

ps2-status:               FAULT

disk-model:               M.2 (S42) 3IE3                          

disk-firmware:            S17411c1

disk-size:                14.9G

disk-type:                Solid State Disk, TRIM Supported

bios-vendor:              American Megatrends Inc.

bios-version:             5.6.5

netvisor-cert-valid-from: Oct  7 07:00:00 2019 GMT

netvisor-cert-valid-till: Oct  8 06:59:59 2039 GMT

switch:                   hydra-ring-2

model:                    S4148-T

chassis-serial:           1816ST9100035

cpu1-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

cpu2-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

system-mem:               3.56G

switch-device:            OK

fan1-status:              OK

fan2-status:              OK

fan3-status:              OK

fan4-status:              OK

fan5-status:              OK

fan6-status:              OK

fan7-status:              OK

fan8-status:              OK

fan9-status:              FAULT

fan10-status:             OK

ps1-status:               FAULT

ps2-status:               OK

disk-model:               InnoDisk Corp. - mSATA 3IE3             

disk-firmware:            S16425c1

disk-size:                14.9G

disk-type:                Solid State Disk, TRIM Supported

bios-vendor:              American Megatrends Inc.

bios-version:             5.6.5

netvisor-cert-valid-from: Apr 16 07:00:00 2018 GMT

netvisor-cert-valid-till: Apr 17 06:59:59 2038 GMT

switch:                   scorp-ring-1

model:                    S4148-ON

chassis-serial:           1906ST9100019

cpu1-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

cpu2-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

system-mem:               3.56G

switch-device:            OK

fan1-status:              OK

fan2-status:              OK

fan3-status:              OK

fan4-status:              OK

fan5-status:              OK

fan6-status:              FAULT

ps1-status:               OK

ps2-status:               FAULT

disk-model:               InnoDisk Corp. - mSATA 3IE3             

disk-firmware:            S16425c1

disk-size:                14.9G

disk-type:                Solid State Disk, TRIM Supported

bios-vendor:              American Megatrends Inc.

bios-version:             5.6.5

netvisor-cert-valid-from: Feb  4 08:00:00 2019 GMT

netvisor-cert-valid-till: Feb  5 07:59:59 2039 GMT

switch:                   vnv-ring-1

model:                    VNV

chassis-serial:           

cpu1-type:                Intel(R) Xeon(R) CPU E5-2623 v4 @ 2.60GHz

cpu2-type:                Intel(R) Xeon(R) CPU E5-2623 v4 @ 2.60GHz

cpu3-type:                Intel(R) Xeon(R) CPU E5-2623 v4 @ 2.60GHz

cpu4-type:                Intel(R) Xeon(R) CPU E5-2623 v4 @ 2.60GHz

system-mem:               30.7G

switch-device:            n/a

disk-type:                Rotational Disk, TRIM Unsupported

bios-vendor:              Phoenix Technologies LTD

bios-version:             6.00

switch:                   pavo-ring-4

model:                    S4112F-ON

chassis-serial:           1941ST9100065

cpu1-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

cpu2-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

system-mem:               3.56G

switch-device:            OK

fan1-status:              OK

fan2-status:              OK

fan3-status:              OK

ps1-status:               OK

ps2-status:               FAULT

disk-model:               M.2 (S42) 3IE3                          

disk-firmware:            S17411c1

disk-size:                14.9G

disk-type:                Solid State Disk, TRIM Supported

bios-vendor:              American Megatrends Inc.

bios-version:             5.6.5

netvisor-cert-valid-from: Oct  7 07:00:00 2019 GMT

netvisor-cert-valid-till: Oct  8 06:59:59 2039 GMT

switch:                   hydra-ring-1

model:                    S4148-T

chassis-serial:           1816ST9100042

cpu1-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

cpu2-type:                Intel(R) Atom(TM) CPU  C2338  @ 1.74GHz

system-mem:               3.56G

switch-device:            OK

fan1-status:              OK

fan2-status:              OK

fan3-status:              OK

fan4-status:              OK

fan5-status:              OK

fan6-status:              OK

fan7-status:              OK

fan8-status:              OK

fan9-status:              FAULT

fan10-status:             OK

ps1-status:               FAULT

ps2-status:               OK

disk-model:               InnoDisk Corp. - mSATA 3IE3             

disk-firmware:            S16425c1

disk-size:                14.9G

disk-type:                Solid State Disk, TRIM Supported

bios-vendor:              American Megatrends Inc.

bios-version:             5.6.5

netvisor-cert-valid-from: Apr 16 07:00:00 2018 GMT

netvisor-cert-valid-till: Apr 17 06:59:59 2038 GMT

switch:                   pyxis-ring-2

model:                    S5224F-ON

chassis-serial:           2035PN8500083

cpu1-type:                Intel(R) Atom(TM) CPU C3538 @ 2.10GHz

cpu2-type:                Intel(R) Atom(TM) CPU C3538 @ 2.10GHz

cpu3-type:                Intel(R) Atom(TM) CPU C3538 @ 2.10GHz

cpu4-type:                Intel(R) Atom(TM) CPU C3538 @ 2.10GHz

system-mem:               7.24G

switch-device:            OK

fan1-status:              OK

fan2-status:              OK

fan3-status:              OK

fan4-status:              OK

fan5-status:              OK

fan6-status:              OK

fan7-status:              OK

fan8-status:              OK

fan9-status:              OK

fan10-status:             FAULT

ps1-status:               OK

ps2-status:               FAULT

disk-model:               M.2 (S42) 3IE4                          

disk-firmware:            L18702C 

disk-size:                29.8G

disk-type:                Solid State Disk, TRIM Supported

bios-vendor:              American Megatrends Inc.

bios-version:             3.40.0.9-10

netvisor-cert-valid-from: Aug 26 04:00:00 2020 GMT

netvisor-cert-valid-till: Aug 27 03:59:59 2040 GMT

switch:                   pyxis-ring-3

model:                    S5224F-ON

chassis-serial:           2035PN8500090

cpu1-type:                Intel(R) Atom(TM) CPU C3538 @ 2.10GHz

cpu2-type:                Intel(R) Atom(TM) CPU C3538 @ 2.10GHz

cpu3-type:                Intel(R) Atom(TM) CPU C3538 @ 2.10GHz

cpu4-type:                Intel(R) Atom(TM) CPU C3538 @ 2.10GHz

system-mem:               7.24G

switch-device:            OK

fan1-status:              OK

fan2-status:              OK

fan3-status:              OK

fan4-status:              OK

fan5-status:              OK

fan6-status:              OK

fan7-status:              OK

fan8-status:              OK

fan9-status:              OK

fan10-status:             FAULT

ps1-status:               OK

ps2-status:               FAULT

disk-model:               M.2 (S42) 3IE4                          

disk-firmware:            L18702C 

disk-size:                29.8G

disk-type:                Solid State Disk, TRIM Supported

bios-vendor:              American Megatrends Inc.

bios-version:             3.40.0.9-10

netvisor-cert-valid-from: Aug 26 04:00:00 2020 GMT

netvisor-cert-valid-till: Aug 27 03:59:59 2040 GMT

switch:                   pyxis-ring-1

model:                    S5224F-ON

chassis-serial:           2035PN8500076

cpu1-type:                Intel(R) Atom(TM) CPU C3538 @ 2.10GHz

cpu2-type:                Intel(R) Atom(TM) CPU C3538 @ 2.10GHz

cpu3-type:                Intel(R) Atom(TM) CPU C3538 @ 2.10GHz

cpu4-type:                Intel(R) Atom(TM) CPU C3538 @ 2.10GHz

system-mem:               7.24G

switch-device:            OK

fan1-status:              OK

fan2-status:              OK

fan3-status:              OK

fan4-status:              OK

fan5-status:              OK

fan6-status:              OK

fan7-status:              OK

fan8-status:              OK

fan9-status:              OK

fan10-status:             FAULT

ps1-status:               OK

ps2-status:               FAULT

disk-model:               M.2 (S42) 3IE4                          

disk-firmware:            L18702C 

disk-size:                29.8G

disk-type:                Solid State Disk, TRIM Supported

bios-vendor:              American Megatrends Inc.

bios-version:             3.40.0.9-10

netvisor-cert-valid-from: Aug 26 04:00:00 2020 GMT

netvisor-cert-valid-till: Aug 27 03:59:59 2040 GMT


Confirm power and cooling components are functioning correctly with the command: switch-status-show 


CLI (network-admin@udev-leo1) > switch-status-show

switch     name         value  units     state 

---------- ------------ ------ --------- ----- 

udev-leo1  F 1          29     degrees-C ok    

udev-leo1  F 2          29     degrees-C ok    

udev-leo1  R 1          56     degrees-C ok    

udev-leo1  R 2          41     degrees-C ok    

udev-leo1  NIC I350     37     degrees-C ok    

udev-leo1  CPU          44     degrees-C ok    

udev-leo1  VCORE        0.87   volts     ok    

udev-leo1  V3SB         3.30   volts     ok    

udev-leo1  V3P3         3.30   volts     ok    

udev-leo1  V1P05 VTT    1.05   volts     ok    

udev-leo1  VBAT         3.15   volts     ok    

udev-leo1  V0P925 SA    0.92   volts     ok    

udev-leo1  V1P5 DDR     1.50   volts     ok    

udev-leo1  V12          12.00  volts     ok    

udev-leo1  V5           5.10   volts     ok    

udev-leo1  V5SB         5.10   volts     ok    

udev-leo1  VCC1P05 PCH  1.05   volts     ok    

udev-leo1  SYSFAN 1     8100   rpm       ok    

udev-leo1  SYSFAN 2     7800   rpm       ok    

udev-leo1  SYSFAN 3     7000   rpm       ok    

udev-leo1  SYSFAN 4     10600  rpm       ok    

udev-leo1  SYSFAN 5     8000   rpm       ok    

udev-leo1  SYSFAN 6     7700   rpm       ok    

udev-leo1  SYSFAN 7     7700   rpm       ok    

udev-leo1  SYSFAN 8     8000   rpm       ok    

udev-leo1  SFP+16 1     38     degrees-C ok    

udev-leo1  SFP+16 2     36     degrees-C ok    

udev-leo1  SFP+12       43     degrees-C ok    

udev-leo1  QSFP+        40     degrees-C ok    

udev-leo1  BCM84328 1   41     degrees-C ok    

udev-leo1  BCM84328 2   42     degrees-C ok    

udev-leo1  BCM84328 3   40     degrees-C ok    

udev-leo1  BCM84328 4   42     degrees-C ok    

udev-leo1  BCM84328 5   45     degrees-C ok    

udev-leo1  BCM84328 6   52     degrees-C ok    

udev-leo1  SWB PSU      38     degrees-C ok    

udev-leo1  BCM56854     52     degrees-C ok    

udev-leo1  VCC12        12.10  volts     ok    

udev-leo1  VCC3         3.42   volts     ok    

udev-leo1  VCC3 CONN A  3.30   volts     ok    

udev-leo1  VDD 1P2V     1.20   volts     ok    

udev-leo1  VDD TRI 1V   1.01   volts     ok    

udev-leo1  VDD TRI CORE 1.02   volts     ok    

udev-leo1  VDD PHY 1V   1.00   volts     ok    

udev-leo1  PSU 2 VIN    230.00 volts     ok    

udev-leo1  PSU 2 VOUT   12.10  volts     ok    

udev-leo1  PSU 2 T1     39     degrees-C ok    

udev-leo1  PSU 2 T2     44     degrees-C ok    

udev-leo1  PSU 2 FAN1   9200   rpm       ok    


Note: The state column should report “ok” for all objects.


Arista NetVisor UNUM: Use the Topology Dashboard and select a switch in the topology map to review the Device Details.


Validate the Software


Confirm the switch is running the latest version of the Netvisor ONE operating system. 


Set the phone-home setting in the switch-setup-show command to "yes" for this command to report, as shown in the sample output.


Confirm the software release with the command: software-show 


CLI (network-admin@udev-leo1) > software-show

version:           6.0.0-6000016331

CLI (network-admin@udev-leo1) > 


To upgrade your software, use the following syntax (example shown):


CLI (network-admin@Spine1) >software-upgrade package nvOS-6.0.0-6000016331-onvl.pkg


Arista NetVisor UNUM: Use the Topology Dashboard and select a switch in the topology map to review the Software version under Device Details.


Customers can download the ONVL Upgrade package from the Pluribus Cloud


north