port-phy-show

This command is used to display information about the physical Layer 1 status of the local switch.

Syntax   port-phy-show

port port-list

Specifies the switch network data port number, range or list of ports. Range for port numbers is from 1 to 64. 

bezel-port bezel-port-string

The bezel port.

state off|admin-down|adminpwrdown|bist|dfe-tuning|down|local-fault|partially-up|remote-fault|up|failed

The state of the port PHY.

mode off|admin-down|adminpwrdown|bist|dfe-tuning|down|local-fault|partially-up|remote-fault|up|failed

The mode of the port PHY.

autoneg autoneg-string

The auto-negotiation setting of the port PHY.

speed speed-number

The speed of the port PHY.

eth-mode configured 1000base-x|sgmii|disabled|1000base-kx|2500base-x|6Gbase-kr|6Gbase-cr|10Gbase-kr|10Gbase-cr|10Gbase-sr|AN-73|Xaui|10Gbase-kx4|10Gbase-cx4|24Gbase-kr4|24Gbase-cr4|40Gbase-kr4| XLaui|40Gbase-cr4|
40Gbase-sr4|no-phy-present|MII|GMII|TBI|10G-XGMII|1G-RGMII|sfi|xfi|cx|kr4|sr4|lr4|er4|cr4|cx4|kx4|caui4|kr2|er2|cr2|sr2|lr2|xlaui2|cx2|sr|lr|er|cr|kx|kr|zr|base-x|sys-default|caui|aoc|xlppi|psm4|base_t|base_cx|base_lx|base_sx|10G-SFI|10G-XFI|GMII

Specify the Ethernet mode as 1000 base or Serial Gigabit Media Independent Interface (SGMII).

max-frame max-frame-number

The maximum number of frames.

def-vlan def-vlan-number

The default VLAN identifier of the port PHY.

dfe-mode static|one-shot|continuous|kr

The DFE mode.

dfe-coarse not-started|in-progress|complete|error

The DFE coarse state.

dfe-fine not-started|in-progress|complete|error

The DFE fine state.

fec fec-string

The forward error correction (FEC).

Defaults   None.

Access   CLI

History   

Version 1.2

Command introduced.

Version 2.1

The parameter eth-mode added.

Version 2.2

The options, disabled|1000base-kx|2500base-x|6Gbase-kr|6Gbase-cr|10Gbase-kr|10Gbase-cr|10Gbase-sr|AN-73|Xaui|10Gbase-kx4|10Gbase-cx4|24Gbase-kr4|24Gbase-cr4|40Gbase-kr4| XLaui|40Gbase-cr4|40Gbase-sr4|no-phy-present|MII|GMII|TBI|10G-XGMII|1G-RGMII|10G-SFI|10G-XFI added.

Version 3.0.0

The parameter link-quality deprecated.

Version 3.1.0

The parameters GII, and disabled added.

Version 7.0.0

The parameter bezel-port added. 

Usage   Switches are equipped with network data ports for host or inter-switch communication. Use this command to display the status of network data ports on the local switch.

Examples  To display the status of network data ports on the switch, use the following command:

CLI (network-admin@switch) > port-phy-show

switch port state speed eth-mode  max-frame def-vlan 

------ ---- ----- ----- --------- --------- -------- 

switch 1    down  10000 xfi       1540      1        

switch 2    down  10000 xfi       1540      1        

switch 3    down  10000 xfi       1540      1        

switch 4    down  10000 xfi       1540      1        

switch 5    down  10000 xfi       1540      1        

switch 6    down  10000 xfi       1540      1        

switch 7    down  10000 xfi       1540      1        

switch 8    down  10000 xfi       1540      1        

switch 9    down  10000 xfi       1540      1        

switch 10   down  10000 xfi       1540      1        

switch 11   down  10000 xfi       1540      1        

switch 12   up    10000 xfi       1540      1        

switch 13   down  10000 xfi       1540      1        

switch 14   down  10000 xfi       1540      1        

switch 15   down  10000 xfi       1540      1        

switch 16   down  10000 xfi       1540      1        

switch 17   down  10000 xfi       1540      1        

switch 18   down  10000 xfi       1540      1        

switch 19   down  10000 xfi       1540      1        

switch 20   down  10000 xfi       1540      1        

switch 21   down  10000 xfi       1540      1

north
    keyboard_arrow_up
    keyboard_arrow_down
    description
    print
    feedback
    support
    business
    rss_feed
    south